Tender For supply of flat bottom flask , rubber stopper , pipette bulb , rubber tubing , brush beaker , brush semi micro test tubes , single layered syringe filters diameter 25mm , silicon tube , brush bottle , brush test tube , syringe filter , beaker 250 ml , reagent bottle wide mouth , pipette 20 ml , pipette 10 ml , spare extractor for soxhlet apparatus , condenser allign , beaker 5 ml , test tube graduated 20 ml , beaker 100 ml , beaker 150 ml , measuring cylinder 10 ml , measuring cylinder 100 ml , pipette 5 ml , standard flask 100 ml , flat bottom flask 1000ml , pipette 1 ml , separating funnel with i c polypropylene stopper squibb shape 250ml , separating funnel with i c polypropylene stopper squibb shape 500ml , separating funnel with i c polypropylene stopper squibb shape 1000ml , burette 25 ml , burette 50 ml , pipettes graduated mohr type 1 ml , pipettes graduated mohr type 1 ml nabl , volumetric flask 10 ml , volumetric flask 25 ml , measuring cylinder 250 ml , receiver delivery adapter short stem 19 26 , beaker low form 10 ml , beaker low form 25 ml , beaker low form 50 ml , beaker low form 100 ml , beaker low form 150 ml , flask flat bottom single neck 1000 ml 24 29 , filter funnel plain long stem 65 mm , filter funnel plain long stem 100 mm , test tube with joint and stopper graduated 20 ml
Tender For corrigendum : rate contract for 02 years( extendable) for purchase of various types of consumables for department of aneaesthesiology, pgims, rohtak- heat & moisture exchange filters (hmef): hepa bacterial and viral fi with hme properties offering optimum hydrophobic filtration performance. gas sampl port, for end tidal co2 monitoring. recommended tidal volume range 150-1200ml.ev pleated filter medium to allow maximum filtration efficiency with minimal resistance flow. low dead space, not more than 45-55 ml. single use, sterile ece/usfda/iso/ , heat&moisture exchangers (hme) filter for pediatric us , recommended tidal volume <600ml.low weight. low dead space. suitable for b ventilated and spontaneously breathing patients. low resistance to flow. corrugated pa medium with high efficiency to recover about 75% of the energy and moisture. single sterile. ece/usfda/iso , heat & moisture exchangers (hme) for spontaneous breathing in tracheostomized patients. suction port to allows access to suct , catheter. clear housing to allow visualization of contamination. integrated oxygen port allow delivery of supplemental oxygen. recommended tidal volume range from 1000ml.compact and lightweight. corrugated paper medium device can be used fo maximum period of 24 hours. single use sterile. minimum resistance anti occlus mechanism. ece/usfda/iso , epidural set. a set containing tuohy's epidural needle minimum length 80m 16g, 17g and 18g, and corresponding gauge epidural catheter with closed tip and th lateral eye, length 90-100 cm and flat filters 0.2 micrometer hydrophilic two way, fill area approx 4.91 cm², priming volume 0.75 ml all connections should be of luer lock ty lor(loss of resistance) syringe, presterilized. ece marked/usfda approved , combined spinal epidural set. containing 18 g touhy epidural needle minimum 80 mm length. pencil point, spinal needle with twist lock system, marking tuohy's needle hub and depth marking on tuohy's needle hub containing correspond clear catheter with connection, closed end and 3 lateral eye of approx. length 90-100 with epidural filter 0.2 micrometer hydrophilic two way, epidural sponge and lor (loss resistance) syringe. ece marked/usfda approved - , needle for spinal anaesthesia, quincke type, same colour coding the hub and stylet, presterilized. usfda and europen ce approved- , (a) 23 g, 90mm length od approx 0.64 mm, , (b) 24g,90mm length od approx 0.5mm with/without introducer , (c) 25g, 90 mm , (d) 26g, 90 mm , (e) 27g, 90mm , paed. spinal needle without introducer, colour coded length 50mm, g, od 0.5 mm, presterilized. usfda and europen ce approved , cuff manometer: allows controlled initial cuff inflation. intermittent press monitoring facility. instant visual confirmation of intra-cuff pressure. simple operation pressure adjustment without need for disconnection or introduction of syringe into syst solid green zone indicates usual cuff pressure range for tracheal & tracheosto tubes.connecting tube is supplied with the gauge for convenient positioning. portable ga and clips easily into pocket. , face mask- clear, reusable, pvc material, transparent for good visibil adjustable cushion for better comfort. , sizes:- , a) 0, , b) 1, , c) 2, , d) 3,0) 4,1) 5- , anatomical facemask made up of antistatic inflating pad, malleable, anatom. chaned to give precise seal and fit comfortably, sizes 1.2.3.4 , disposable lma with preformed curve 90 degree like ilma with airwa tube with standard connectors for anaesthesia circuit. us fda approved. sizes 1, 1.5,2, 2.5,3,4,5 , resuable pressure infusion bag for administration of fluid to patient unde pressure, compatible with 500 ml fluid bags, flexible, stury, pvc tubing and manometer stop cock and hand pump, latex free , clear pressure- monitoring lines, which can withstand pressure up to 500 psi with minimal damping, non kinkable, pre-sterilized, disposable, id/ed1/2 mm. length 100 cm, 150cm & 200 cm. low dead space but pe may be optional
Tender For corrigendum : tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes r
Tender For supply, delivery and installation of advanced testing mechanism, lab equipment for conducting daily quality of drinking water in tanuku municipality supply, delivery & installation of compact photometer pf-12plus make: mn, germany (or) any equivalent isi make model no: 919250 technical specifications: type: filter photometer with microprocessor control, self-test and auto-calibration light source: xenon lamp optical system: automatic filter wheel with 7 interference filters wave length: 345 nm / 436 nm / 470 nm / 540 nm / 585 nm / 620 nm / 690 nm plus 1 compartment for an additional filter, 860 nm led for ntu measurement wave length accuracy: ± 2 nm, bandwidth at half transmission: 10 nm?12 nm photometric range: ± 3 e photometric accuracy: ± 1 % long term stability: < 0.002 a/h measuring modes: more than 100 preprogrammed tests and special methods, absorbance, transmission, factor, standard, nephelometric turbidity measurement; 50 freely programmable methods pre programmed tests: nanocolor tube tests, visocolor eco tests and powder pillows turbidity measurement: nephelometric turbidity measurement at 860 nm (based on iso 7027), 1?1000 ntu cuvette slot: round tubes 16 mm od data memory: 1000 results, glp conform display : backlit graphic display, 128 x 64 pixel auto off: inactive or automatic shutdown after 5 min, 10 min, 15 min, 20 min, 60 min internal quality control: with nanocontrol nanocheck 2.0 operation: self-explanatory menu guidance, plastic foil keypad, test selection via parameter lists language: de / en / fr / es / it / nl / hu / pl / pt / cz / id / sl / tr / my operating range: 10?40 °c (50?104 °f), max. 80 % relative humidity (non-condensing) power supply: via usb power supply, standard or rechargeable batteries or accu-pack weight: 0.7 kg dimensions (l x w x h): 215 x 100 x 65 mm scope of delivery photometer, software dvd, manual, visocolor eco test instructions, 4 batteries, 4 empty test tubes, funnel, beaker, syringe, usb cable, calibration cuvette, cleaning cloth and certificate in rugged case hazardous material: no , supply, delivery & installation of mm42dp-ph,ec,tds portable multi-parameter water quality meter with ph, conductivity electrodes. includes: mm-42dp(main unit)+mm4-ph(1m) ph electrode+mm4-ec(1m) ec electrode make: dkk-toa corporation, japan. technical specifications : measuring method : ph : glass electrode method orp : platinum electrode method conductivity : ac bipolar method dissolved oxygen : optical type temperature : thermistor resistor display unit :custom lcd(with backlight) measurement items/ranges : ph : ph0.000 to ph14.000 mv (orp) : -2000 to 2000mv conductivity:0.1ms/m to 10s/m d0: 0.00-20.00mg/l or 0.0 to 200.0% electrical resistivity:0.1o.m to 10ko.m (converted from electric conductivity) salinity (nacl):conversion from electrical conductivity salinity (pss: practical salt):conversion from electrical conductivity total dissolved solids (tds):conversion from electrical conductivity temperature:0.0to100.0°c display range : ph : ph-2.000to ph16.000 mv (orp) : 0to99.99mg/l 0to999.9mg/l 0to9.999g/l 0to99.99g/l 0to999.9g/l (automatic/manual range switching) temperature :-5.0to110.0°c do:0.00-22.00mg/l or 0.0 to 220.0% display resolution : ph :0.01ph/0.001ph mv (orp) :1mv conductivity :0.05%fs electrical resistivity :0.05%fs, salt :0.01%(nacl)0.01psu(pss) total dissolved solids (tds) :0.01%fs temperature :0.1°c, repeatability (instrument body): ph :within ±0.006ph mv (orp) :±2mv, conductivity :±0.5%fs, do:when combined with 8mg/l ±0.1mg/l or 100%±1% electrical resistivity :±0.5%fs salt :±0.5%fs, total dissolved solids (tds) :±0.5%fs temperature :within ±0.2°c ph temperature compensation range: atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0? electrical conductivity temperature compensation range : atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0°c atc off (no temperature c
Tender For auction sale of depot non ferrous scrap - cond & u/s stainless steel scraps such as pipes/ sheets, offcuts, hot boxes, bins,flasks,trough sheets ,rectangular hot water boiler & cylindrical hot water boiler,iv ratchet, rmpu filters,ss canvas, impeller,bfm housing, lhb & sg cd mesh,fresh air housing, ss air duct asssembly, ss dust bins, mugs,underslung water tanks,flex cable short and long, ocb filter assesmbly,needle&syringe destroyer,bed side locker,ss clip assembly,flasks,food store container,reservoir tanks,hot pot,three seaters,dressing drums,ss rope,plates, buckets,cups,forks, rbc cubiclebottle holders, iv coupler housing, clip assembly,food warmer,stainless steel bolts,hand rails,tea cans,water tanks,plates,storage container,rachet handles,filters,canvasses,jars, trays,jugs,kettles,plates, jugs,wall protectors, wash basins , clip assembly stainless steel,storage box,mixie jar, landing door ,vessels,owens,tanks,tumblers, strips, lavatory pan in lay,berth utility wire rods,filters of various types & sorts ,hot case,geysers,sterlisers,leggings,liquid receiver,commode adapter, stainless steel vessels including tea cans,bio toilet ball valves with/ without available attachments and all other stainless steel scrap nature items including magnetic steel items, trough sheets and the above lot is with ferrous attachments,steel/stainless steel pipes/light fittings /filters with/without ferrous fittings /attachments/magnetic steel attachments /adherings, in full/part/broken and in loose parts. note: 1) removal of ferrous/glass/rubber /thread mesh/ wood and other attachments etc are not permitted. 2) cutting is not permitted 3) if any extraneous material/material of aluminium in nature found in the lot, the same should be handed over to the custodian at the time of delivery. pl no 98090719