Web Analytics Made Easy - StatCounter

Underground Drainage System Repair Tenders

Get complete information related to latest Underground Drainage System Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Underground Drainage System Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Underground Drainage System Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45536897 Due date: 27 Jun, 202627 Jun, 2026 20.00 Lacs
Tender For bid to ras supply of site clearance and amp earthwork is 1200 , kero heater , pcc is456 , rcc m20 footing and column and slab , reinforcement steel fe500 , brickwork 230mm is1077 and flooring anti skid , internal plaster 12mm , doors flush and windows alluminum and glass , electrical led and wiring , plumbing and sanitary , ceiling gypsum vip , painting exterior and interior external lighting and poles , water supply tank and pump , transportation and logistics remote area , contingencies and solar panel 5kva and invertor and battery 5kva , generator 5 kva electrical led and wiring is 732 , mirror 5 h 2w ft and bench 5 h 2w ft , chair plastic with arm , toilet sheet western with exhaust fan and water faucet and hand jet assy , electric fitting work , changing room 6 by 6 by 10 ft and bathroom 6 by 6 by 10 f , multipurpose hall structure , chair vip sofa and centre table , podium and tt table and carrom set , yoga mats fire extinguisher , 86 inch interactive pannel , drainage and cement road work tin shed wk on viewer seating iron poles and tin sheet hooks screw and iron channel , ground civil work , excavation work

CTN :45692458 Due date: 15 Jul, 202615 Jul, 2026 75.91 Lacs
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r

State Government

CTN :45583211 Due date: 04 Jul, 202604 Jul, 2026 20.83 Crore
Tender For corrigendum : construction work of new cross drainage, repairing of cross drainage , structure & bridge repair work & other miscellaneous work on various roads as & when required or in emergency under district (r & b) division junagadh panchayat (6th attempt)

State Government

CTN :45669029 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For expression of interest for preparation of dpr for upgradation work for bannimantap ground by enhancing the existing seating capacity, upgradation work for stadium with permanent roofing structure, rising of existing ground with proper drainage system

State Government

CTN :45653834 Due date: 06 Jul, 202606 Jul, 2026 21.97 Crore
Tender For construction of cross drainage structure on various roads in morbi district - package -1

State Government

CTN :45654864 Due date: 06 Jul, 202606 Jul, 2026 7.46 Crore
Tender For construction of cross drainage structure on various roads in morbi district - package -2

Central Government And Public Sector

CTN :45332724 Due date: 29 Jun, 202629 Jun, 2026 5.37 Lacs
Tender For corrigendum : supply of supply of 3 tr non inverter ductable ac as per bsnl specifications , itc of 3 tr non inverter ductable ac as per bsnl specifications , supply and fixing copper piping of 0.75 inch with nitrite foam insulation as required , supply and fixing copper piping of 0.625 inch with nitrite foam insulation as required , supply and laying 4 core 4 sq mm pvc insulated copper cable as required. , supply and laying 4 core 2.5 sq mm pvc insulated copper cable as required. , supply and fixing 1 inch dia pvc pipe for water drainage as required , s fixing ms structure of suitable size as required , making covering of extra oper space of leakge as required , supply and fixing 8way double door 4 and 24 nos tpn mcb db , supply and fixing 5a to 32 a tpn c curve mcb in extg db as required , supply and fixing 60a four pole isolator in extg db as required , supply and fixing single ploe blanking plates , supply and fixing 8 swg gi wire for loop earthing as required , supply and fixing 150mm x 50mm x 1.5mm perforated ms cable tray

State Government

CTN :45625596 Due date: 29 Jun, 202629 Jun, 2026 16.12 Crore
Tender For emergency road (new bridge work) work on various roads under porbandar (r & b) division (construction of new cross drainage work, repairing of cross drainage, structure work, labour & machinary work, construction of new bridge work & other miscellaneous work)

corporations/Associations/Others

CTN :45563708 Due date: 22 Jun, 202622 Jun, 2026 4.20 Lacs
Tender For to carry out comprehensive field survey, assess the existing drainage structure & based on their findings provide design of suitable drainage structure for enhancement of gora to bhanadra road

State Government

CTN :45570693 Due date: 30 Jun, 202630 Jun, 2026 10.78 Lacs
Tender For construction of drainage water passage way structure near the house of naru mia at chhat lalbazar mouza under lalbazar gp within sitalkuchi panchayat samity
 Loading, Please wait...

Connect us via What's Up