Web Analytics Made Easy - StatCounter

Ups Wiring Tenders

Get complete information related to latest Ups Wiring Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ups Wiring Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ups Wiring Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :39889103 Due date: 10 Apr, 202510 Apr, 2025 18.71 Lacs
Tender For tender for supply of equipment / material , design, erection, testing commissioning for sop to jsv for sewerage treatment plant by prov. 11/.4 kv 100 kva s/stn. at gosan a/w 11 kv ht/lt line , in section bharmour-1 under esd bharmour ed chamba - supply part 11/.4 kv 100 kva distribution sub station, 11/.4 kv 100kva dtr (rec sep. ord 11/1976, prov. st pole pole 9 mtr. long w/l 200 kgs, muff for steel tubular pole with concrete filling, x-arm: [channel iron (100x50x5 mm), length : 2800 mm x 2 nos] for incomer line, ms a.i.(50x50x6 mm), length: 2800 mm x(1 nos for las ), x-arm: [channel iron (75x40x5 mm), length : 2800 mm x 4 nos] for supporting do fuse unit & go switch, x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos] for transformer bed, x-arm [channel iron (100x50x6 mm), length : 460 mm x 2 nos for supporting main channel of transformer], ms a.i.(50x50x6 mm), length: (2800 mm) x 2 no., ms angle iron (35x35x5 mm), length : 460 mm x 2 nos, ms a.i.(50x50x6 mm), length: (950 mm) x 2 nos. of bed knee bracing, ms angle iron (50x50x6 mm), length : (2800 mm) x2 nos for transformer lt distribution box and g.o switch fixing assembly, ms angle iron (50x50x6 mm), length : (450 mm)x1 nos for transformer lt distribution box and g.o switch fixing assembly, g.o. switch handle supporting: [c.i. (75x40x6mm), length: 460mm for transformer lt distribution box and g.o switch fixing assembly, g.o ab switch unit (11kv,400,663ka) tripple pole o/d type, d.o fuse unit, surge arrester, 9 kv station class, discs insulator sets (comp. 1 no. disc: ^^(porcelain, bs, 12 kv, 90 kn) i/c dead end clamps etc.), stay set complete, stay wire (7/3.15mm)( 10 kg per stay set), pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 100kva trf. as per specification, half clamp (m.s. flat 50x6), full clamps (m.s. flat 50x6), m. s. nuts & bolts off sizes (galvanised coated) [prefarably 16mm or more (with flat and spring washer), aluminium thimbles, copper thimble, danger plate, barbed wire (rec sp f 3/1981), lt cable 3-1/2 core-95mm sq., energy meter (3-phase, 4-wire) dlms compliant 1000/5a ct type for 63 kva transformer, alluminium paint, prov.acsr, 6/1/3.35 mm, prov. hp make aiq desktop model hp 200 g4 with intell core 3-10110u-10 gen.processor, 8gb ddr4 ram expenditure upto 16 gb, itb, hdo (t2qorpm)2st antiglare led desplay withfhd (1920x1060) integrated hd graphics & webcam, 2xusb, 3.0 2xusb, 2.0 cardreacer. audio part vgnhdmi/dp port, 10x100, 1000mcomdliant lan usb key board & mouse internalspl. connectivity bo2 11 b/g/n/ac pl windows etc. with three years on site warranty. (ii) 650va offline ups system with12vx7ahx2nos: 158vah/smf batteryto povide20 min. battery back upwith three year warrantyon ups &battery from delivery with printer, hp monocrom laser printer (a4) hp laser 108a with prints upto 20 ppm,64 mb ram 600x600 dpl print resolution 150 sheets paper tray capacity usb 2.0 port- one year waranty, beetal m88 plan phone (one set contains 2 nos phone), beetal m71n land line phone, 11 fin oil filled room heater make havel, prov. transformer plinth protection for 100kva s/stn structure a/w chain link fencing, angle iron gate etc. for dtr fencing., erection part 11/.4 kv 100 kva distribution sub station, 11/.4 kv 100kva dtr (rec sep. ord 11/1976, prov. st pole pole 9 mtr. long w/l 200 kgs, muff for steel tubular pole with concrete filling, x-arm: [channel iron (100x50x5 mm), length : 2800 mm x 2 nos] for incomer line, ms a.i.(50x50x6 mm), length: 2800 mm x(1 nos for las ), x-arm: [channel iron (75x40x5 mm), length : 2800 mm x 4 nos] for supporting do fuse unit & go switch, x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos] for transformer bed, x-arm [channel iron (100x50x6 mm), length : 460 mm x 2 nos for supporting main channel of transformer], ms a.i.(50x50x6 mm), length: (2800 mm) x 2 no., ms angle iron (35x35x5 mm), length : 4

State Government

CTN :39889104 Due date: 10 Apr, 202510 Apr, 2025 16.49 Lacs
Tender For tender for supply of equipment / material , design, erection, testing commissioning for sop to jsv for lis kakdolu by prov. 11/.4 kv 100 kva s/stn. a/w 11 kv ht/lt line , in section maredi under esd chamba-ii ed chamba - supply part 11/.4 kv 100 kva distribution sub station, 11/.4 kv 100kva dtr (rec sep. ord 11/1976, prov. st pole pole 9 mtr. long w/l 200 kgs, muff for steel tubular pole with concrete filling, x-arm: [channel iron (100x50x5 mm), length : 2800 mm x 2 nos] for incomer line, ms a.i.(50x50x6 mm), length: 2800 mm x(1 nos for las ), x-arm: [channel iron (75x40x5 mm), length : 2800 mm x 4 nos] for supporting do fuse unit & go switch, x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos] for transformer bed, x-arm [channel iron (100x50x6 mm), length : 460 mm x 2 nos for supporting main channel of transformer], ms a.i.(50x50x6 mm), length: (2800 mm) x 2 no., ms angle iron (35x35x5 mm), length : 460 mm x 2 nos, ms a.i.(50x50x6 mm), length: (950 mm) x 2 nos. of bed knee bracing, ms angle iron (50x50x6 mm), length : (2800 mm) x2 nos for transformer lt distribution box and g.o switch fixing assembly, ms angle iron (50x50x6 mm), length : (450 mm)x1 nos for transformer lt distribution box and g.o switch fixing assembly, g.o. switch handle supporting: [c.i. (75x40x6mm), length: 460mm for transformer lt distribution box and g.o switch fixing assembly, g.o ab switch unit (11kv,400,663ka) tripple pole o/d type, d.o fuse unit, surge arrester, 9 kv station class, discs insulator sets (comp. 1 no. disc: ^^(porcelain, bs, 12 kv, 90 kn) i/c dead end clamps etc.), stay set complete, stay wire (7/3.15mm)( 10 kg per stay set), pipe earthing with gi,charcoal & salt, prov. lt distribution panel with mccb (160 a, 10 ka, 4p,1 no.) & sfu (32 a 5 no. rewireble) for 100kva trf. as per specification, half clamp (m.s. flat 50x6), full clamps (m.s. flat 50x6), m. s. nuts & bolts off sizes (galvanised coated) [prefarably 16mm or more (with flat and spring washer), aluminium thimbles, copper thimble, danger plate, barbed wire (rec sp f 3/1981), lt cable 3-1/2 core-95mm sq., energy meter (3-phase, 4-wire) dlms compliant 1000/5a ct type for 63 kva transformer, alluminium paint, prov.acsr, 6/1/3.35 mm, prov. hp make aiq desktop model hp 200 g4 with intell core 3-10110u-10 gen.processor, 8gb ddr4 ram expenditure upto 16 gb, itb, hdo (t2qorpm)2st antiglare led desplay withfhd (1920x1060) integrated hd graphics & webcam, 2xusb, 3.0 2xusb, 2.0 cardreacer. audio part vgnhdmi/dp port, 10x100, 1000mcomdliant lan usb key board & mouse internalspl. connectivity bo2 11 b/g/n/ac pl windows etc. with three years on site warranty. (ii) 650va offline ups system with12vx7ahx2nos: 158vah/smf batteryto povide20 min. battery back upwith three year warrantyon ups &battery from delivery with printer, hp monocrom laser printer (a4) hp laser 108a with prints upto 20 ppm,64 mb ram 600x600 dpl print resolution 150 sheets paper tray capacity usb 2.0 port- one year waranty, prov. transformer plinth protection for 100kva s/stn structure a/w chain link fencing, angle iron gate etc. for dtr fencing., erection part 11/.4 kv 100 kva distribution sub station, 11/.4 kv 100kva dtr (rec sep. ord 11/1976, prov. st pole pole 9 mtr. long w/l 200 kgs, muff for steel tubular pole with concrete filling, x-arm: [channel iron (100x50x5 mm), length : 2800 mm x 2 nos] for incomer line, ms a.i.(50x50x6 mm), length: 2800 mm x(1 nos for las ), x-arm: [channel iron (75x40x5 mm), length : 2800 mm x 4 nos] for supporting do fuse unit & go switch, x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos] for transformer bed, x-arm [channel iron (100x50x6 mm), length : 460 mm x 2 nos for supporting main channel of transformer], ms a.i.(50x50x6 mm), length: (2800 mm) x 2 no., ms angle iron (35x35x5 mm), length : 460 mm x 2 nos, ms a.i.(50x50x6 mm), length: (950 mm) x 2 nos. of bed knee bracing, ms angle iron (50x50x6 mm), length : (2800 mm) x2 nos for transform

State Government

CTN :39892154 Due date: 09 Apr, 202509 Apr, 2025 NA
Tender For quotation for 5 kva ups - wiring works at m. sc. computational biology lab palayad", thalassery.

State Government

CTN :39872433 Due date: 08 Apr, 202508 Apr, 2025 NA
Tender For general-lsgd - formation of office of the district joint director wayanad- arrangements of infrastructure - providing additional electrical installations in a block of civil station, kalpetta.-ups wiring-general electrical work

corporations/Associations/Others

CTN :39853496 Due date: 19 Apr, 202519 Apr, 2025 NA
Tender For supply installation testing commissioning and maintenance of hybrid lan and ups wiring in various th dh gh across kerala

corporations/Associations/Others

CTN :39843401 Due date: 19 Apr, 202519 Apr, 2025 NA
Tender For supply installation testing commissioning and maintenance of hybrid lan and ups wiring in various th dh gh across kerala under ehealth project

State Government

CTN :39839932 Due date: 09 Apr, 202509 Apr, 2025 NA
Tender For quotation for 5 kva ups wiring for computer lab department of environmental studies, mangattuparamba campus

State Government

CTN :39798135 Due date: 25 Mar, 202525 Mar, 2025 4.45 Crore
Tender For corrigendum : rewiring and fixtures works for msedcl cabin, ups wiring for msedcl network switches and miscellaneous works at prakashgad, bandra (e).

CTN :39145983 Due date: 28 Mar, 202528 Mar, 2025 NA
Tender For corrigendum : providing of custom bid for services - procurement and installation of ups wiring

State Government

CTN :39784797 Due date: 26 Mar, 202526 Mar, 2025 2.32 Lacs
Tender For deposit-male icu facilities shifting to the fourth floor of taluk head quarters hospital thiruvalla- installation of 3 kva ups and ups wiring-general electrical work
 Loading, Please wait...

Connect us via What's Up