Get complete information related to latest Vacuum Bottle Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vacuum Bottle Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vacuum Bottle Tenders.
Tender For repair of vaccum circuit breaker - taking out vacuum interruptor bottle , supply and fixing vacuum interruptor bottel suitable for ht vcb , testing of vcb on load after installation of vcb complete all as specified and directed , taking out battery power pack from vcb at domestic area complete all as specified and directed , material and labour for battery power pack for 11 kv vcb i p 230v ac o p 24vdc complete all as specified and directed
Tender For corrigendum : supply of veterinary instruments and equipments - allis tissue forceps (20 cm.), artery forceps curved (15 cm ), artery forceps straight (15 cm ), forceps s.s. (20 cm), forceps s.s.(15 cm), haemostat straight s.s.(17.5 cm), haemostate curved s.s. (15 cm. ), mayo s scissors curved isi (s.s. 15cm), mayo s scissors straight isi (s.s. 15cm), scissors straight s.s.(12.5 cm), scissors straight s.s.( 17.5 cm), surgical gloves (standard), surgical mask (standard), suturing needle (assorted size) (traumatic/atraumatic cured/st.), suture thread silk/ nylon (10 mt. reel no.100, 0, 1, 2, 3), chromic cat gut (100, 0, 1, 2, 3 no.), needle holder s.s.(15cm), instrument trolly, dressing drum s.s. round 20 gauge (height 30cmx30cm dia.), b.p. blades (no. 22, 23, 24, 11, 12, 13,14, 16, b.p. handle s.s.(no. 3 ), b.p. handle s.s.(no. 4), kidney tray s.s.(15 cm length), tray small ss (250mmx300mm), hypodermic needle (15 x3/4"), hypodermic needle (18 x3/4"), vaccutainer with needle (with vacuum, 10 ml and needle of double bewell 16 no.), electrcally operated needle and syringe destroyer. destruction rate max. 1 minute per needle of 1.6 mm thickness with 80 mm length. min. 350 cutted hubs of syringes with needle burnt residue., bloodless castrator for small animals 9 (made of special high carbon steel coated for protection against rust formation), castrator imported, i/v fluid stand (s.s.), intra venous set (disposable 0 standard) ), scalp vein set (21 no. 0 22 no.), electric dehorner (30 cm length), trocar canula for sheep s.s.(15 cm), teat syphon (ss), drenching bottle (large) (metal 500 m), drenching bottle (small) (metal 200 ml), doctor coat tericot (free size), plastic apron, macentosh sheet (double colour), rubber arm sleeves with latex gloves (no. 9), gum boot, dog muzzle (assorted size), dog nail cutter (standard), measuring cylinders (50 ml graduated borosil glass ), measuring cylinders of (100 ml graduated borsil glass ), medicine carry bag (nylon 600 dpu coated padded, multipocket for medicine and surgical equipments ), jar with lid ss (2 kg. capacity), jug ss (2 ltr. cap.), thermos s.s. double insulated (1 ltr. cap., 30cm length, 7.5cm mouth dia with soulder carrying strap.), bucket ss (12 ltr capacity), california mastitis kit, centrifuge machine (bench top) for general purpose, canopy tent with carrying bag. frame made of steel powder coated pipe (23 gauge) 0 tetron cover (waterproof) with two folding chairs and one folding table, vaccine carrier (1.6 lit capacity with 4 ice packs), microscope binocular, autoclave electric, calf puller ss 316/304., animal catching device, cold boxes vaccine storage capacity 20 ltr. weight fully loaded 43.3 kg. empty weight 17.5 kg. external surface material plastic, internal lining material plastic , insulation material polyurathene, insulation thickness 110 mm,, refrigerator, thermocautery, veterinary urine analyzer with accessories, animal sling for large animals, cold cabinet/ cold room with 25% capacity of racks as deep freezer and 75 % as cold cabinet having 2-8 degree celcius temperature, digital display, alarm system for temp. beyond set point, hematology analyzer with accessories (three parts), semi automatic veterinary serum analyzer with accessories, verticle cold cabinets for vaccine storage, with storage temperature 2-8 degree celcius. temperature holding time atleast 12 hrs, at power failure. adjustable shelves., hot air oven, incubator, ice liner (ice lined refrigerator or freezer) compressor compartment0 hermetically sealed high quality compressor 230 v 50/60 hz. relatively noise less fan to cool down the compressor. all steel tubes protected with special compound against rust formation. 1 thermostate pre-stetted from the factory for 2 c - 8 . control panel situated at the front of the unit. light indicators for different functions, 1 digital thermometer to indicate the internal temperature, latest cooling system. insulation with thick polyurethane foam. foaming agent- cyclo
Tender For supply of vacuum interrupter bottle, type wl-34370 series used for current interruption, fault protection, o ver current and short circuit protection. wl-34370 series suitable for electrotecknica make indore type 11 kv v acuum circuit breaker. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : two year rate contract for supplying of disposable laboratory items - disposable plastic test tube for cross matching without label; size 13 x 75 mm; capacity 5 ml; pack size :-1 x 100, sample tube for auto analyzer; size 13 x 75 mm; pack size :-1 x 100, sample cup for auto analyzer for i lab; pack size :-1 x 100, disposable micro titer pipette tips up to 200 l; color white; pack size :-1 x 1000, disposable micro titer pipette tips up to 1000 l; color blue; pack size :-1 x 1000, disposable micro titer pipette tips 0.5 to 20 l; color any color; pack size :-1 x 1000, disposable micro titer pipette tips 30 to 300 l; clear graduated; pack size :-1 x 1000 (yellow), transparent plastic sample tube for processing for urine with label and without cap; size 13 x 100 mm; capacity 7 to 8 ml, capillary glass tube for c.t. 75 mm in length, uniform base without anticoagulation; pack size 1x100, micro cover slip for urine for no. 1; square size 18x18 mm smooth edges transparent without any spot; pack size 1 pack = 20 x 10 gms, haemocytometer cover slip no. 1; (size 20 mm x 26 mm x 0.4 mm), new improved neubaur counting chamber having silver coated 9 mm 2 ruled area (for counting wbcs & rbcs), glass marking pencil (red, white, green, blue), glass slide: size length 75 mm, width 25 mm +/- 1.0 mm, thickness 1.35 +/- 0.1mm clean and transparent with ground edges & lint free packing; pack size 1 x 50 iso/ce certified, container for urine, sputum, stool sample collection, leak proof with wide mouth, conical wide bottom & screw cap, 50 ml capacity with label for patient name, ward/opd and registration number, pack size 1 x 100 (urine container), esr disposable pipette with tube, tube 12 x 75 mm clean transparent with graduation at 0.4 ml and 2 ml should allow to fill by air pressure through the rubber piston blood lift up up to zero level. pipette should be made with transparent polystyrene with graduate d scale 0 to 180-200. it should be fine finished; pack size 1 x 100, evacuated blood collection tube with spray dried k2edta with lavender safety closure. it should be made of clear latex free polyethylene terphthalate. size 13 x 75 mm with 4.0 ml, volume capacity. batch wise sterility/pyrrogenicity/toxicity certificate should be given. it should be us-fda/ce certified. firm should provide training to technicians/nurses regularly for blood collection. clinical services should be documented by company. pack size 1 x 100 ( edta vials), sodium citrate evacuated tubes for coagulation test with vacuum (with na. citrate 0.109 m/3.2% plastic tube made of clear latex free polyethylene terphthalaste with light blue safety closure, 13 mm x 75mm vol. 2.7 ml. batch wise sterility/pyrogenicity/toxicity certificate should be given. it should be us fda/ce certified, firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size 1 x 100 ( pt vials), evacuated tubes for silica-clot activator/silicon coated made of clear latex polyethylene terphthalate with safety closure 13 x 75 mm vol. 4.0 ml. it should be us fda/ce certified. batch wise sterility/pyrrogenicity/toxicity certificate should be given. firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size 1 x 100 ((plain vials), blood collection needle 21 or 22 gauge with cap for evacuated tube. it should be us fda/ce certified, sterility certificate firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size 1 x 100 (blood collection needles 21 or 22 gauge), evacuated tube needle holder; pack size 1 x 5, test tube stand 96 holes, 13 mm diameter in two shelves fully autoclavable multi colored; pack size 1 x 1, wash bottle with delivery snore poly ethylene flexible with screw cap 500 ml; pack size 1 x 1, variable volume pipette 10 l to 100 l. fully autoclavable and ivd approve iso/ce certified
Tender For supply of vacuum circuit breaker (single bottle) along with matching accessories suitable for co nventional electric locomotives as per clw specification no. clw/es/c-47 alt.-g or latest. each set c onsists of: (1). vcb assembled: 01 no. (2). air dryer: 01 no. (3). rc damping panel assembly: 02 no s. (4). male (inbuilt in vcb): 01 no. (5). female connector - 35p:01 no. (6). accessories: 01 set (6.1) male stud coupling g3/8 : 01 no. (6.2) male adaptor g3/8 edxg1/2%u201d: 03 nos. (6.3) hose pipe 3/8 (f)-700mm: 01 no. (6.4) hose pipe 3/8 (f)-250mm: 01 no. (6.5) copper washer : 04 nos. [ warr anty period: 30 months after the date of delivery ]