Get complete information related to latest Vibrator Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vibrator Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vibrator Scrap Tenders.
Tender For corrigendum : providing of custom bid for services - rpnc242113 rfq line item 00010 sub line item 00010 annual rate contract for expert services of ms ge for trouble shooting and maintenance of vibration monitoring system at pnc complex,custom bid for services - rpnc242113 rfq line item 00010 sub line item 00020 annual rate contract for expert services of ms ge for trouble shooting and maintenance of vibration monitoring system at pnc complex,custom bid for services - rpnc242113 rfq line item 00010 sub line item 00030 annual rate contract for expert services of ms ge for trouble shooting and maintenance of vibration monitoring system at pnc complex,custom bid for services - rpnc242113 rfq line item 00010 sub line item 00040 annual rate contract for expert services of ms ge for trouble shooting and maintenance of vibration monitoring system at pnc complex,custom bid for services - rpnc242113 rfq line item 00010 sub line item 00050 annual rate contract for expert services of ms ge for trouble shooting and maintenance of vibration monitor
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; contract for pulsation and vibration analysis of hp ammonia pump 11p1d system and associated piping its supports in unit 11 of urea plant at rcf thal; bu..
Tender For installation of plant distributed control system (dcs) for complete fgd process control along with interfacing and synchronization with existing plant software, all associated cabling, installation of vibration monitoring system (vms) and erection
Tender For corrigendum : supply and installation of necessary equipment for updating the fire and safety system installed in regional office, chandigarh - diesel engine driven main fire pump supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.(for 1620 lpm at 56 m head) note- the head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest farthest point., control panelfabrication, supply, installation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :incoming250a, 50ka 4 pole mccb, ics=100% icu rating ,digital voltmeter 0-500v with selector switch digital ammeter (0-250 a) with selector switch & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps, set of copper bus bar 300a.outgoing( note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump125 a, 50ka tpn mccb, ics=100% icu, with fully automatic star/delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.jockey pump63 a, 50ka tpn mccb, ics=100% icu, with suitable hp fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.diesel engine controlcontrol for diesel engine comprising -automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low lub. oil pressure, high water temp and engine on indication, battery charger suitable for 12v/24 v dc with boost and trickle selector switch, 0-30 v dc volt meter, and 0- 20 a dc ammeter. all standard relays and accessories for automatic operation of diesel enginesystem controllerdesigning, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in sequence as per specification consisting of relays, timers. sens
Tender For supply of w90418109141 fibre optic generator end winding vibration monitoring system for 16 channels alongwi , (w90418109168) panel & accessories for gen. end winding vibration monit. system including laptop/ se , w90418109176 junction box and accessories for fo end wndg vibration mon. system , (w90418109133) commissioning of fibre optic generator end winding vib. monitoring system , (w90418109192) fibre optic sensor with conditioner& 6 mtr integrated cable for generator ew vibratio , w90418109206 fibre optic sensor with conditioner & 10-meter integrated cable for generator end windi
Tender For bid to ras corrigendum : custom bid for services - rprc244459 rate contract for condition monitoring of rotary equipments at panipat refinery and petrochemical complex-00010 condition monitoring_rotary equip for pr mechanical, 00020 90,000.000 ea- collection and trending of overallvibration, time waveform & fft displacement, velocity & acceleration) at all the bearing locations of equipment train in three directions(horizontal, vertical, axial). collection & trending of bearing condition (shock pulse/ acoustic/peak view/envelop) at all the bearing locations of equipment train in one radial direction. collection & trending of bearing temperature at all the bearing locations of equipment train. collection & trending of amperage data from local panel display of equipment driver (motor). list of equipment not covered/measured in the planned route due to unsafe condition/inaccessible measuring points to be provided daliy. appx. 2000-2500 equipments are to be monitored out of which approx. 1000-1200 equipments will be running at any given time. hence, effectively data is to be collected for the equipments on weekly/fortnightly/monthly route as per instruction of e-i-c based on criticality of the equipment. 00030 30,000.000 ea- detailed analysis of collected data (mentioned in line no. 10 above) or collected data using 4-20 ma buffer output from online protection system using trends, time waveform, fft, spectrum, waterfall etc. & collection of relative/absolute phase for diagnosis confirmation for all bearing locations and accordingly creating vibration report for all equipments which are having abnormal/high vibrations on weekly basis for all critical/semicritical equipments as well as for non-crtical equipments which are having high/abnormal vibrations. preparation of report consisting of equipment condition (marginal/critical) w.r.t. vibration level as per iso 10816, vibration table (velocity & acceleration in h-v-a directions), vibration trends (graph) of at least last 6 readings, velocity spectrum, acceleration spectrum, time waveform, temperature, amperage, observation & recommendations of maintenace activities to be carried out. reports are to be sent within 04 hrs of data collection. also closure report submission after completion of maintenance activity. note: the unit of measurement ea represents each detailed analysis report. billing will be done on per report basis. 00040 10.000 ea online motor current signature analysis and torque signature analysis., 00050 9.000 ea charges for visit of insitu balancing expert on call:- carrying out in-situ dynamic balancing job of id fans, fd fans, overhung fans, pumps, motors etc