Get complete information related to latest Visual Inspection Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Visual Inspection Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Visual Inspection Tenders.
Tender For non-destruction test on concrete members visualinspectionvisualinspection and photography performing a visual survey of the shed steel structure as per specified in specification of documents , site testing charges concrete upv test ultra sonic pulse velocity test upv test in accordance with as per specified in specification of documents , rebound hammer test schmidt rebound hammer test for determining the concrete compressive test , half cell potential accordance in with astm c876 half cell potential to assess the probability of corrosion of reinforcement sac code 98346 , carbonation in accordance with bs 1881 201 1986 clause 2 22 carbonation test to measure extent of carbonation from the concrete surface sac code 998346 , profometer scan test on rcc members to assesss covers spacing of bars including approximate diameter bar , core test core cutting and compression test for rcc structure in accordance as per specified in specification of documents , preparing detail report as per specified in specification of documents
Tender For bid to ras custom bid for services - otr case for habitability maintenancerepair works onboard ins shakti--degutting of crca paneling of wc's and shower areas in js bathroom, ss bathroom and officer's bathroom along with securing arrangement at 1 dk, 2 dk, 01 dk and 02 dk water leakage observed from bathroom to passageway. renewal of crca paneling forming partition between passageway and bathroom to be undertaken. (no. of bathrooms - 10 nos approx. area - 300sqmt) sqmt renewal of foundation and securing brackets of paneling in js bathroom, ss bathroom and officer's bathroom at 1dk, 2dk, 01 dk and 02 dk view heavily corroded/ damaged/ broken. (no of bathroom - 10 nos, mat-ms, thickness- 5mm) rmt 1. . fitment of securing arrangement of wc's in js bathroom and ss bathroom view securing arrangement damaged. (no of wc's - 20 nos) nos inspection window along with frames and locking mechanism of wc's in js bathroom, ss bathroom and officer's bathroom heavily corroded/ thinned/ broken at 1 dk, 2dk, 02 dk, inspection window and locking mechanism of doors to be repaired/ renewed as per existing dimension. qty - 20nos nos repair/ renewal of bath fittings (shower head assembly/ hand bar) in js bathroom, ss bathroom and officer's bathroom as per marine standard, view defective. qty - 40 nos, material- ss nos 2. undertake repair/ renewal of wash basin taps in js bathroom, ss bathroom and officer's bathroom as per marine standard, view defective. qty- 50 nos nos 3. undertake repair/ renewal of ceramic wash basin in officer's bathroom, view defective/ cracked/ damaged. qty- 20 nos nos doors and associated fittings 4. undertake fitment of nwt doors along with door coaming and frames at various locations as per existing dimension, view door deformed/ defective (nwt door will be provided by ss. qty- 30 nos) nos 5. repair/ renewal of hydraulic door closer of nwt door in main passageway, offices and officers cabin, view door closer not working/ defective. qty - 50 nos nos main alleyway and passageway 6. renewal of aluminum strip for securing of crca panel in main rmt page 36 of 74 alleyway at various location to be undertaken as per existing dimension. qty- 200 rmt 7. undertake repair/ renewal of hand rails along with bracket in main passageway at 2 dk, 1 dk, 01 dk, 02 dk, 03 dk,& 04 dk. material - ai, qty- 200 rmt rmt messes and office spaces 8. renewal of locking arrangement of lockers/ drawers in following spaces view broken/ damaged (including hinges and associated fittings). qty -400 nos :- (a) chart table drawer in bridge and flag bridge (b) mess lockers, elsa lockers and shoe locker in all messes (c) drawers of office spaced and stores (d) pharmacy compartment, sickbay and pmo office nos 9. undertake repair/ renewal of foundation and securing bracket of locker in messes, view corroded/ damaged. material - ms & ai. qty50 nos nos 10. undertaken repair/ renewal of securing arrangement of book shelves in messes, view defective. material - wood. spares to be proved by refitting s agency. qty - 80 nos. nos 11. undertake repair of ss wash basin along with drainage arrangement in machinery workshop, electrical workshop, mechanical workshop and hull workshop. qty- 12 nos. nos 12. undertake repair of metallic furniture/ cupboard (opening door fitted with glass) in pharmacy compartment size- (184x122 & 184x 78) cm. spares to be provided by refitting agency. qty- 02 nos nos galley and dining hall 13. repair/ renewal of wash basin drain line in jsdh, ssdh, ss scullery, js scullery, officer's pantry, co's pantry & admiral pantry view blocked. choked. qty - 20 nos nos 14. undertake repair/ renewal of panel along with securing bracket in ship's galley (at deck head and bulkhead), view defective. mat- ss, qty- 50 sqmt sqmt 15. undertake repair/ renewal of ss metallic locker along with locking mechanism in ship's galley. qty- 10 nos. spares to be provided by refitting agency. nos 16. repair/ renewal of water tap in ship's galley and officer's
Tender For supply of structural audit of building - visualinspection and photography , rebound hammer test , ultrasonic pulse velocity test upv test , cover meter test , half cell potential test , carbonation test , core test , chemical test , vetting of report from approved govt engg college report , report preparing detailed report with stating the
Tender For tender for supply of non-destruction test on concrete members visualinspectionvisualinspection and photography performing a visual survey of the shed steel structure as per specified in specification of documents , site testing charges concrete upv test ultra sonic pulse velocity test upv test in accordance with is1331 i part i 1992 by portable ultrasonicas per specified in specification of documents , rebound hammer test schmidt s rebound hammer test for determining the concrete compressive test ref is 133 ii part 2 , core test core cutting and compression test for rcc structure in accordance with js 516 on rcc membeers as per specified in specification of documents , profometer scan test on rcc members to assesss covers spacing of bars including approximate diameter bar , half cell potential in accordance with astm c876 half cell potential to assess the probability of corrosion of reinforcement , carbonation in accordance with bs 1881 2011986 clause 2 22 carbonation test to measure extent of carbonation from the concrete surface sac code 998346 , preparing detail report visualinspection and photographs not test results analysis of not data results preparing of drawings strucrural ananysis conclusion and recommendations
Tender For third-party inspection/project managementagency for the services of project management,construction, supervision and design reviewinsite/offsite inspection & testing of materials,machinery, equipments, review of qap forproviding irrigation water for filling ofvarious ponds/reservoir/cds (41 villages) ofrajkot, jasadan and kotada sangani taluka ofrajkot district. thrue pipeline by lifting waterfrom link-3 package-4 (near link-3 package-5pumping station) including supplying and layingm.s, d.i. and h.d.p.e. pipeline of different dia withall allied works etc complete.
Tender For third-party inspection/project managementagency for the services of projectmanagement, construction, supervision anddesign review insite/offsite inspection &testing of materials, machinery, equipments,review of qap for providing irrigation waterfor filling of various ponds (38+6 village) ofmuli, sayla and wadhwan taluka, districtsurendranagarthrough pipeline by liftingwater from botad branch canal escape nearlimbdi bhogavo-ii reservoir includingsupplying and laying m.s., d.i. and hdpepipeline of different dia with all alliedworks etc
Tender For supply of polyster staple fibre pillow to size 45x30x10 cms. and weight 400 gms.+/-5% with pr otective cover cloth of 100% cotton mill made superior quality for 2ac & 3ac coaches. constr uction details: material polyster staple fibre, fibre content 100% virgin hollow fibre non comp ressed in the form of sheets. identification of fibre hollowness will be as per is:667/81 (reaffir med 2008) each pillow should be stamped with indian railway logo, manufacturer name, trade m ark, month & year of manufacture in such a fashion that it will not be washed away while repe ated washing. tolerance limit for product size: plus or minus 2% and with following sampling and testing method : 1. sampling plan for visualinspection-is 2500:2000 part 1, gil ii, aql 2.5 2. sa mpling plan for laboratory testing- as per is 745:2003 for sampling purpose only. 3.test requirement and its methods- i) identification of fibre and % composition of filling material as per is:667/1981. ii) identification of fibre and % composition of protective cloth as per is:667/198 1. iii) hollowness of fibre (microscopic examination). . " [ warranty period: 30 months after the date of delivery ]