Get complete information related to latest Volt Meter Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Volt Meter Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Volt Meter Repair Tenders.
Tender For providing and fitting of essential items and allied material for snow clearance operation at nathatop sanasar road - supply, testing and commissioning of 48v smps float cum boost automotive battery charger with moveable trolley stand for snow operation at nathatop - sanasar roadgeneral technical requirements for battery charger suitable for 48v vrla type battery1.) type -float & float cum boost charger for vrla type, full wave, full controlled type. 2. ) ratings- 15 a float cum boost for 48v, 150 ah vrla type battery 3. ) ac input- i) voltage 415 vac 10%ii) frequency 50hz 5% iii) phase 3 - phase 4.) d.c.output voltage settings -nominal float fc 48/54.5v (adj. by + 20%, - 5% bc 48/66.5v (adj. by + 2%, - 5%) 5.) output current limit 15a 15a 6. ) power conversion ac to dc by means of three phase full wave, half controlled bridge rectifier consisting of thyristors and diodes. 7.) voltage regulation at bridge output. + 1% of set value for + 10% input voltage variations, 0-100% load variation. 8. ripple voltage less than 3% rms without battery connected. 9. efficiency more than 80% at full load 10. protections (a) input side ac input mccb & elbs with input on/off switch and fuses, contactor (b) output side dc output mccb with output on/off switch and fuses. (c) protection current limit protection, soft start feature, surge suppressor. fast semiconductor fuses for rectifier bridge. (d) control circuit fuses (e) capacitor circuit rectifier hrc fuses. (f) over-voltage cut-back (g) charger over load / short circuit (h) blocking diode 11. controls and switches followings controls and switches are provided in the system 1 ac input source mccbs with interlocking 2 dc output mccb 3 auto/manual float/boost mode selector switch. 4 float and boost voltage variable potentiometers. 5 manual voltage adjustment potentiometer 6 test push button 7 reset push button 8 battery current adjustment potentiometers 9 heater s power supply switch 12. features the following features are provided in the systems: 10 soft start on dc side 11 class-f insulation for all magnetic 12 automatic voltage regulation. 13 automatic changeover from float to boost and vice versa based on current, drawn by battery. 14 filter circuit to eliminate ripple. 15 charger current limit 16 separate battery path current limit. 17 built-in auto phase reversal of operation. 13. meters f.c. b.c. (i)input voltmeter (i) common (ii) input ammeter (ii) input ammeter (iii) output voltmeter (iii) output voltmeter (iv) output ammeter (iv) output ammeter. battery voltmeter battery ammeter earth leakage ammeter 14. indications phase on lamps (ii) output on lamp a)phase on lamps (ii) output on lamp. (iii) charger on float led (iv)charger on boost led. 15. annunciation with audiovisual alarms. (i) ac input mains failure (ii) input phase failure (iii) ac under voltage iv) input phase failure v) rectifier fuse failure vi) output fuse failure vii) filter fuse failure viii) dc under voltage ix) dc over voltage x) charger trip xi) capacitor fuse fail xii) output mccb tripped xiii) charger over load xiv) earth leakage xv) dc earth fault xvi) alarm supply fuse failure xvii)battery low condition. v) rectifier fuse failure vi) output fuse failure vii) filter fuse failure viii) dc under voltage ix) dc over voltage x) charger trip xi) capacitor fuse fail xii) output mccb tripped. note : all the alarms shall be provided through electronic display cards. audio alarm through buzzer, visual indication through 10 mm leds & alarm ackn. / reset and led provision is through push buttons. 16. operating ambient temperature surrounding the panel 00 to 500 c 17. surrounding the panel relative humidity. 0-95% non-condensing 18. panel (i) protective grade (ii) cooling (iii)paint ip 42 natural air-cooled smoke grey of iss-692 shade a) average winding temperature rise over ambient temperature b) insulation class c) insulation breakdown voltage. as per relevant iss. f 3 kv for 1 min withstand. 19. cables 1100 v
Tender For digital ammeter with led display, size 96 mm x 96 mm, multiline for measuring current r,y & b, 0-600 amps ac , ctr, 1a / 5 a programmable, with aux. supply 24 / 110 v dc, 4 va, class 1make acce ptable: l & t, ae, socomec, siemens, schneider, yokins, rishabh.the meter shall be supplied along with c alibration certificate traceable to nabl standard. [ warranty period: 12 months after the date of delivery ]
Tender For corrigendum : design, supply, installation, commissioning, training of various type of equipments for esdm (electronic system design and manufacturing) of msme training centers located at greater noida, bengaluru, puducherry and idemi mumbai on turnkey basis - decade resistance box , ct/pt calibration system , multifunction calibrator , decade capacitance box , ct analyzer , standard resistors , standard weights (el class) , pippete calibration system , low temperature bath (-80 to ambient degree temperature) , frequency counter , energy meter test system (3 position) , precision temperature stabilised resistance standard (high) , decade inductor box , precision temperature stabilised resistance standard (low) , sound level calibrator , digital power analyser , decade resistance box (4 nos.) , process calibrator , hv divider , decade mega ohm box , standard weights (e2 class) , 6 and half dmm , temperature indicator , time interval meter , temperature indicator with compensation , standard weights (f1 class) , semi-micro balance (upto 200 gms) , tachometer calibrator , standard thermocouple (type s) without compensation , sound level analyzer , standard platinum resistance temperature (prt) detector , precision balance (upto 6.1 kg) , thermo-couple calibartion furnace (300 to 1100 degree temperature) , lcr bridge , humidity measurement probe , dry block calibrator (ambient to 600 degree temperature) , anechoic chamber with radiated susceptbility and radiated emission test system , alltitude test chamber , compact emc tester , environmental chamber , digital pressure controller (dead weight pressure tester) , line impedance stablizing network , harmonics/flicker measurement test system , impulse generator , rf shielded chamber , vibration plus environmental chamber , three phase regulated variable power source , humidity generator, relative humidity , bump/shock test system , heat deflection temperature test set , vibration test system , electronic load , conducted rf immunity simulator , rohs testing lab - inductively coupled plasma optical emission spectrometer (icp-oes) , thermal shock chamber , ac dc current source , ultra precision capacitance bridge , esd simulator , horizontaland verticlal flame chamber , rohs testing lab - energy dispersive x-ray fluorescence spectrometer (edxrf) , single phase regulated variable power source , precision energy standard , rohs testing lab - gas chromatograph mass spectrometer (gc-ms) , ingress of water test system - i set , rohs testing lab - ion- chromatograph (ic) , needle flametest chamber , salt spray chamber , dust chamber , digital storage oscilloscope , defibrillator proof test set , thermostat endurance test set , flexing test apparatus , electrical safety tester , winding resistance meter , temperature recorder , radiation meter , tracking test apparatus , gas detector , cord anchorage test set , digital multimeter (handheld/desktop) , glow wire test apparatus
Tender For supply of digital earth clampmeter for earth/ground resistance & leakage current measurement[ suitable for up , milliamp process clamp meter (4- 20ma) , digital light/lux meter , true rms wireless leakage current clamp meter 3ma- 60a
Tender For bid to ras supply of handheld digital multimeter , dry cabinet with rh controller , lcr meter smart tweezers , soldering station with soldering tips , ac slash dc high sensitivity current probe , insulation tester , handheld lcr meter with accessories , usb to rs 422 converter uport 1450i-g2 , usb to rs 422 converter uport 1250i-g2
Tender For corrigendum : camc of qty twenty four machineries and ndt equipments at component repair shop - upstroke hydraulic press with hyd tank and motor pt no indimech hydraulic press sl no 7193 , extruder with machine pt no indimech extruder sl no nayg crs ewm 01 , rubber mixing machine pt no indexpell rubber mixer sl no nayg crs rmm 02 , stand for test acceptance of air system unit pt no c 3757 ue 82 sl no 01 , stand for test gen purpose hydraulic rig pt no c 3390ue 82 sl no 02 , stand for test fuel rig pt no c 3869mue 82 sl no 03 , hydraulic callibration set pt no 63b 0001na sl no 512 , pneumatic calibration set pt no 63b 0001na sl no 513 , climatic chamber minus 40 degree to 20 degree pt no climatic chember minus 40 deg sl no nayg crs cc 03 , charging unit of fire extinguisher system pt no zssp sl no 1 , sonic bond master 1000 multimode with accessories pt no 9020342 reve sl no 1000c12465079107 , ultrasonic plant pt no uzu 2 kor u sl no 169 , ultrasonic filter cleaning rig pt no uc 500w sl no 10541 , magnetic particle flaw detector pt no ferro test gwh 15 sl no 1548752 , bond testing flaw detector pt no bond master 600 sl no 60002161046 , ultrasonic flaw detector pt no epoch 650 sl no 160164102 , eddy current flaw detector pt no nortech 600 sl no 60002161072 , ultrasonic thickness meter pt no 38 dl plus sl no 161265703 , high pressure compressor pt no revell tc3 1 by 2 mk 7 compressor sl no nayg crs hpc 04 , electronic weighing machine capacity 300 kgs pt no ds 415 sl no g415028098 , oven rane 0 degree celceius to minus 300 degree celceius pt no oven 330 deg sl no nayg crs oven 05 , tu hydraulic trolley tu0014 sl no 001 , installation set for checking and pressing hp vessels pt no upos 1 sl no 28 1018107 1 , halon gas filling system pt no jj 2023 point 02 sl no lf 57
Tender For corrigendum : supply of soldering and de-soldering station , digital multimeter , digital earth clamp tester , lan cable tester , cable length measurement meter , cable route tracer , professional tool kit with case , digital earth tester , rf adopter connector kit , digital multimeter clamp type , audio output power meter , battery analyzer , ac dc clamp meter , digital clamp current meter , connector with cables n-type
Tender For corrigendum : supply of tester , rodo meter , dec tester , dmw meter , insulation tester , megger , analog earth tester , four terminal tester , current meter , multimeter , digital clamp meter , true rms , handheld digital multimeter , digital multimere , clamp meter
Tender For supply of digital leakage clamp meter current up to 400 ma/4/100a ac.min. resolution : 0.1 ma, jaw size, 28 mm with auto power function, frequancy sel ector switch. make: kyuritsu,/koico/meggar. [ warranty period: 30 months after the date of delivery ]