Web Analytics Made Easy - StatCounter

Wall Panel Repair Tenders

Get complete information related to latest Wall Panel Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wall Panel Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wall Panel Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39171113 Due date: 27 Feb, 202527 Feb, 2025 1.80 Crore
Tender For replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the energizer without

Central Government/Public Sector

CTN :39230595 Due date: 05 Mar, 202505 Mar, 2025 57.98 Lacs
Tender For provision of concertina coil and related civil works for perimeter wall at ins dweeprakshak under ge (navy) lakshadweep

Central Government/Public Sector

CTN :38557855 Due date: 11 Feb, 202511 Feb, 2025 35.62 Lacs
Tender For corrigendum : special repairs to perimeter security wall of nsb and provision of deficient geysers in sma at ins shivaji lonavla

Central Government/Public Sector

CTN :38861043 Due date: 14 Feb, 202514 Feb, 2025 2.41 Crore
Tender For corrigendum : special repairs of power fencing on existing perimeter wall of naval dockyard, visakhapatnam under ge (i) dm, visakhapatnam

CTN :39199035 Due date: 13 Feb, 202513 Feb, 2025 NA
Tender For repair and panting work of perimeter wall new and old adm block gate cisf quarter guard check post opium factory wall of goaw neemuch.

Central Government/Public Sector

CTN :39199897 Due date: 11 Feb, 202511 Feb, 2025 84.9 Thousand
Tender For provn of additional elevated security posts with guard room for strength of nco or alongwith perimeter wall at parel line samba

Central Government/Public Sector

CTN :38919782 Due date: 20 Feb, 202520 Feb, 2025 3.05 Crore
Tender For corrigendum : provn of perimeter wall at demolition ground at mil stn beas under ge kapurthala

Central Government/Public Sector

CTN :38566336 Due date: 11 Feb, 202511 Feb, 2025 161.49 Crore
Tender For corrigendum : sh- extension and strengthening of runway 05/23 and construction of link taxiway, ptt, apron, isolation bay, perimeter road, operational boundary wall, drainage system, etc., including allied works of civil and electrical at keshod airport

CTN :39150641 Due date: 06 Feb, 202506 Feb, 2025 15.38 Lacs
Tender For interlockin of paver path and repair and construction of perimeter wall at pipli zoo kkr

Central Government/Public Sector

CTN :39139019 Due date: 20 Feb, 202520 Feb, 2025 NA
Tender For spl rps to compound wall of p-133 old naval butchery at nad alwaye, provn of 20 in numbers perimeter lights outside of wed (koc) warehouse at nad alwaye and spl rps for replacement of main lt panel board of laundry plant (p-214) at inhs sanjivan
 Loading, Please wait...

Connect us via What's Up