Get complete information related to latest Wall Panel Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wall Panel Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wall Panel Repair Tenders.
Tender For construction of guide wall to protect erosion of canal in minors and earth work on bank malkakhedi and nirkhi minors of raigarh distributary.
Tender For maintenance of road agartala-simna near manipuri chowmuhani to kailori, mohanpur, west tripura(l-0.15km) during the year 2025-26/sh rcc retaining wall, box culvert (1.00 x1.00)m, earth filling, bamboo palasiding with allied works.
Tender For supply of provision of lighting arrangement for the watch tower along with solar system at kushinagar airport : : - design and sitc of off grid solar system of 1 kwp capacity along with suitable capacity inverter and 2 nos. of 150 ah solar tubular battery along with necessary module mounting structure & civil works like foundation etc. as required at site for upssf watch tower in operational area of airport., supply of 4c x 6 sq. mm xlpe insulated & pvc sheathed, armored aluminium conductor cable of 1.1kv grade as per is 7098 (part i) 1988 with up to date amendments etc. complete as required., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required.upto 35 sq. mm (clamped with 1mm thick saddle), laying of hdpe pipe upto size 50 mm complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required., laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/hume/metal pipe as required.upto 35 sq. mm, supplying and fixing of following way single pole and neutral, sheet steel, mcb distribution board 240 v, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 6 way, double door, supplying and fixing 6 amps to 32 amps rating, single pole, 240 volts, 10 ka, c curve, miniature circuit breaker suitable for inductive loads in the existing mcb db complete with connections, testing and commissioning etc. as required., supplying and fixing dp mcb 32 amps, double pole, rating, 240 volts, 10 ka, c curve, miniature circuit breaker in the existing mcb db complete with connections, testing and commissioning etc. as required., wiring for light point/fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit, with modulat switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper stranded conductor single core cable etc. as required.(group c), wiring for circuit/ sub-main wiring along with earth wire with 2x2.5 sq.mm+ 1x 2.5 sq.mm earth wire.sizes of frls pvc insulated copper conductor, single core stranded cable in surface/ recessed steel conduit as required., supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required., supply of 20 watt led batten surface mounted suitable for operation on 230 volt,50hz ac supply, complete etc as required., supply of 400 mm, 2100 rpm wall mounting swinging fan suitable for single phase 230 volt, 50 hz ac supply complete with motor, capacitor, mounting clamps etc. with all accessories as required complete., installation, testing and commissioning of pre-wired led fitting luminaries etc. of all types (surface/recessed) & street lights complete with all accessories. directly on ceiling/ wall , including connection with 1.5 sq.mm frls pvc insulated, stranded, copper conductor single core cable with flexible conduits and coupler and earthing etc. as required., installation of wall mount fan in the existing opening including making good the damage, connections, testing and commissioning etc. as required.upto 450mm sweep., supply of led street light of minimum lumen output of 3600 lumen made up of pressure die cast aluminum housing with membrane filter and have ip66 optical as well as electrical compartment with wide operating voltage range of 230+/- 10 percentage complete with all accessories as required., providing & fixing 32/40 mm dia b class gi
Tender For providing and fixing of vitrified floor tile providing and fixing of wallpaneling repair of toilet and repair work at ground floor room museum building g b pant social science institute prayagraj
Tender For construction of boundary wall around material recovery facility and waste to compost plant, earth filling in dump site, for construction of material recovery facility and waste to compost plant, construction of retaining wall around material recovery
Tender For raising of boundary wall including concertina wire work, earth work in filling, water proofing and repair of r.c.c ugt and repair of civil structure (i.e pump chamber, boundary wall etc)
Tender For raising of boundary wall including concertina wire work, earth work in filling, water proofing and repair of r.c.c ugt and repair of civil structure (i.e pump chamber, boundary wall etc)
Tender For providing laying of di k9 rising main including removal of slush, const of retaining wall, after achieving the omc mdd of good earth filling, gsb cc 1 2 4, elevated shaft, rcc hatch boxes, const of culverts coming in the alignment at kotkapura
Tender For construction of boundary wall in front of plot no1200 p sector 9a gurugram earth work,brick work cement concrete in sector 9a gurugram and all other works contingent thereto
Tender For construction of retaining wall and breast wall to support the exposed foundation of earth retaining structure at chainage 1015/03-08 between rnan-mozn section under cgm/umb