Web Analytics Made Easy - StatCounter

Wash Basin Drainage Pipe Tenders

Get complete information related to latest Wash Basin Drainage Pipe Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wash Basin Drainage Pipe Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wash Basin Drainage Pipe Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :44965118 Due date: 07 May, 202607 May, 2026 3.28 Lacs
Tender For corrigendum : construction of brick masonary open drain at patel nagar booster in ambala city.

corporations/Associations/Others

CTN :45034145 Due date: 20 May, 202620 May, 2026 43.16 Lacs
Tender For providing of construction of drain for 2x210 mw ash water recirculation system at ptpp, parichha. - engaging jcb on hire bases including hire fuel driver helper etc. complete. , clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. , demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of material within 50 metres lead as per direction of engineer-in-charge in lime mortar , earth work in excavation by mechanical means (hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. , filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. , providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - all work up to plinth level : 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) , providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level :1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) , "centering and shuttering including strutting, propping etc. and removal of form for : suspended floors, roofs, landings, balconies and access platform" , steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.thermo-mechanically treated bars , random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : cement mortar 1:6 (1 cement : 6 coarse sand) , brick work with fly ash (non modular) bricks of class designation 7.5 in foundation and plinth incement mortar 1:6 (1 cement : 6 coarse sand) , 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) , supplying and filling in plinth with jamuna sand under floors, including watering, ramming, consolidating and dressing complete. , "hire charges of pump set of capacity 4000 litres/hour for dewatering which include cost of services of operating staff, cost of lubricating oil, diesel / petrol/ kerosene oil , other consumables for running the plant and machinery. the hire charges of plant machinery on per day basis are for single shift of eight working hours." , providing and laying non pressure np-4 class (heavy duty) r.c.c. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 900 mm dia rcc pipes.

Central Government And Public Sector

CTN :45030114 Due date: 28 Apr, 202628 Apr, 2026 8.23 Lacs
Tender For construction of brick drain and path jinordwar from heera sharma's house to front culvert tak and tarik jee's house to krishna jee's house in ward no-01 under ??nagar parishad, khagaul

CTN :44974559 Due date: 07 May, 202607 May, 2026 12.48 Lacs
Tender For corrigendum : sirohi bahali block nangal choudhary const of rcc drain and brick drain from sc colony to nh drain

CTN :44995862 Due date: 02 May, 202602 May, 2026 3.60 Lacs
Tender For construction of rcc culverts near jenda chettu block no.11 and block no.04 and raising of cc drain innerside wall with brick masonary from block no.11 to block no.1 beside apcpdcl office at rajeev gruhakalpa of mangalagiri tadepalli municipal corporation under municipal general funds

CTN :45030208 Due date: 04 May, 202604 May, 2026 14.97 Lacs
Tender For repairing of brick drain with slab from basuwa chowk to radhe krishn mandir to new dharmsala in ward no 5 and 7 under nagar panchayat mahagama

CTN :45010504 Due date: 07 May, 202607 May, 2026 NA
Tender For supply of drain works at madurai lpg plant : : - excavation less than 1.5 , pcc 1 2 4 , brick work , plastering 12mm , breaking of pcc rcc

Central Government/Public Sector

CTN :44985997 Due date: 15 May, 202615 May, 2026 35.00 Lacs
Tender For repair /replacement of sewage line, manholes, septic tank, brick drain and certain miscellaneous b/r works in domestic area at 20 wing af stn under ge (af) bagdogra.

Central Government/Public Sector

CTN :45002525 Due date: 05 May, 202605 May, 2026 14.14 Lacs
Tender For tender for supply of airconditioners and other items at gwalior airport -supply of 1.5 tr inverter type , 5 star rating as per latest bee norms , hiwall , split airconditioner with rotary compressor operating on refrigerant r-32a/r-410a. the body of indoor unit shall be made of abs/hips/gs condensing unit should be of 100% copper coil & having all safety , air filters , evaporator , condenser , cordless remote , electronic operation control & all accessories supplied with the unit by oem etc as per manufacturer standards suitable for operation on 230 volts , 50 hz , single phase , ac supply , complete as required at site. , supply of 2.0 tr inverter type , 5 star rating as per latest bee norms , hi-wall , split airconditioner with rotary compressor operating on refrigerant r-32a/r-410a. the body of indoor unit shall be made of abs/hips/gs condensing unit should be of 100% copper coil & having all safety , air filters , evaporator , condenser , cordless remote , electronic operation control & all accessories supplied with the unit by oem etc as per manufacturer standards suitable for operation on 230 volts , 50 hz , single phase , ac supply , complete as required at site. , installation , testing , commissioning of 2.0/1.5 ton split inverter a/c i/c supply & fixing of iron angle structure stand suitable for outdoor unit , makeup interconnection , top up refrigerent , painting i/c necessary civil works complete as required , providing suitable size pvc pipe for drawing the gas/drain pipe and wire etc through the concrete/brick wall as required. , supply & fixing of extra copper refrigerant piping for suction and delivery line with all accessories suitable for following capacity acs i/c insulation , gas refiling , power & control cabling etc completed as required.of standard gauge for installation of above units as required at site. , supply & fixing of hard pvc drain piping of proper dia for installation of above units as required at site beyond company provided standard length. , supply , installing , testing and commissioning of 5kva voltage stabilizer suitable for 1.5/2.0 tr split ac units on wall including providing connections etc. as required. (model-v guard vgb 500 or equivalent). , sitc of industrial type ro water purifier having capacity minimum 50 lph capacity with uv & membranes , sediment filter , carbon filter , tds control , water level sensor , 3 prefilter (1 carbon candle and 2 micron filter) , auto flush & output water etc as per manufacturers specifications i/c , making inlet and outlet water connections with water cooler complete. suitable for operation on 230 v , single phase , 50 hz ac supply. , supply of water cooler of fully stainless steel body with thermostate cut- off automatic operation having cooling capacity 40 ltr. per hour and storage capacity 80 ltr per hour , working on 220 v , 50 hz , ac supply including automatically controls with temperature , over load protection , water line connection etc. complete as required . , supply of desert air cooler (duct type) with following minimum specifications as given below. fan size - 18 inch & above. fan speed - 1400rpm/ 3 speed. water tank capacity - 110 litres & above - jointless tank. material of cooler body/sump tank - galvanized steel sheet (isi marked to is 277 latest) cooling media - aspen/wood wool. cooling area - 500sqft & above. cooling pads - on 4 sides. , supply of frp wall support ladder of size 12feet meeting specifications as provided in the technical specifications of the agreement of the work(make - arham/ladderman/sumer/y-access) , supply of frp wall support ladder of size 20feet meeting specifications as provided in the technical specifications of the agreement of the work(make - arham/ladderman/sumer/y-access) , supply of frp tiltable telescopic tower ladder of size 32feet meeting specifications as provided in the technical specifications of the agreement of the work. (make - arham/ladd

State Government

CTN :44997324 Due date: 08 May, 202608 May, 2026 43.24 Crore
Tender For construction of precast and rcc box type drain in place of old brick drain at dichaon road (road id 1229) under sd-2, swr-2, new delhi
 Loading, Please wait...

Connect us via What's Up