Tender For purchase of equipments for materials testing lab for civil department - spring testing machineload & displacement sensing load cell capacity: 0 10 kn accuracy: 1% fs (better if 0.5%fs) displacement sensor lvdt / digital encoder accuracy: 0.5 mmmachine design frame: rigid steel frame with crosshead movement type: mechanical screw with hand wheel (simple & robust) or electromechanical actuator (for smoother, controlled motion) crosshead travel: ~150 200 mm safety guards: transparent shields around moving partsfixtures & accessoriesspring testing compression plates (ground & parallel) tension hooks / eyelets for extension springs set of spacers / adapters for small springs tensile testing standard tensile grips wedge or screw type calibration certificate for load cell standards complianceensure compliance with basic material test standards such as: astm e4 / iso 7500-1 calibration of force measurement astm e8 / iso 6892 tensile performance & accuracy load accuracy: 1% fs displacement accuracy: 0.5% repeatability: 0.5%, rockwell cum brinell hardness testing machine min initial test force :10kgf, total test force range : 60kgf,100kgf,150 kgf, max. height of specimen :215 mmmin distance from indenter center tomachine wall :132 mm accessories : steel ballpreferred indentor 1/16" preferred steel ball: 1/16"and with all standard accessories to run the machine, direct shear machinestandard compliance:the equipment shall confirm to bureau of indian standards is 2720 (part 13) and equivalent astm international astm d3080.technical specifications:shear box size: 60 mm 60 mm 25 mm specimen size (complete with grid plates, porous stones, and specimen cutter).normal load capacity:minimum 5 kn with loading yoke and calibrated loading hanger set.shear load capacity:minimum 2.5 kn or 5 kn with calibrated proving ring (with calibration certificate).rate of strain (shear displacement):variable speed drive with controlled displacement ranging from 0.01 mm/min to 1.25 mm/min (motorised model preferred for uniform rate control).displacement measurement:horizontal displacement dial gauge: 0.01 mm least countvertical displacement dial gauge: 0.002 mm or 0.01 mm least countloading frame:rigid, heavy-duty loading frame with corrosion-resistant finish.drive system:motorised with single phase 220 230 v, 50 hz power supply.accessories (to be supplied complete):shear box assembly, proving ring with calibration chart, two dial gaugesloading weights and hanger, porous stones (2 nos.), specimen cutter, tool kit, flow table test apparatusdimensions and specifications as per is 9103, table top made from flat metal plate, minimm thickness 1.5 mm. table top size: 700 mm 700 mm, with flatness tolerance of 1.5 mm. table top marked with: scribed cross at centre, lines parallel to table edges and central circle of 200 mm diameter underside of table top reinforced to prevent distortion. total mass of table top: 16 1 kg. table top, base frame front and upper stops provided as per is 9103. lower front edge fitted with two rigid stops to transfer load directly to base frame. base frame designed to transfer impact load directly to supporting surface, minimizing bounce. stop watch digital - 2 nos scale 1 mtr 2 nos mounting wooden platform 300 mm height amc for 3 years inclusive.
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to
Tender For supply of bench top meter for measurement , electronic balance , benkelmen beam , centrifuge extractor , radar gun , deval abrasion value , ultra sonic pulse velocity instrument , torsion testing machine , spring material test , core cutting machine with drill bit , beam deflection appratus , strain gauge indicator , weight hanger , wind tunnel , open channel flume , friction loss along a pipe , minor losses in pipe appratus , reynolds apparatus , universal milling machine , mechanical press , resistance spot welding , welding hand shield , welding helmet , welding helmet auto darkening helmet , tool and cutter grinder machine , hydraulic hacksaw machine , gas cylinder filled with argon gas for tig welding , gas cylinder filled , crucibles set , pouring ladles , crucible tongs , slag spoons and skimmers set , indoor ducted chimney with furnace , moulding box , bernoulli theorem demonstration module , energy losses in pipes , fluid friction measurement , orifice and mouthpiece flow apparatus , orifice and venturi meter demonstrator , pitot tube apparatus , determine meta centric height , notch tank apparatus , determine density and viscosity of oil , determine critical reynolds number of tube , free and force vortex flow apparatus , impact of jets on vanes , palton turbine test rig , francis turbine test rig , kaplan turbine test rig , centrifugal pump test rig , reciprocating pump test rig , performance of a two stage reciprocating air compressor , air blower apparatus , heat transfer coefficient of composite wall apparatus , natural convection heat transfer apparatus
Tender For purchase of equipments for ece department - function generator frequency range: 0.1 hz to 5 mhz display: 4 to 6 digit led display output waveforms: sine, triangle, square, pulse, ramp . amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v, strain gauge trainer kit ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual., temperature measurement kit sensors: rtd (pt-100), thermocouple (fe-k/j-type), and/or thermistor (ntc). display: 3 digit led/lcd digital display (typically 200 mv fsd). temperature source: portable water kettle or heater block. signal conditioning: on-board circuitry for amplification, linearization, and cold junction compensation. test points: multiple 2 mm / 4 mm banana sockets for monitoring input/output signals. power supply: 230 v ac, 50 hz, single-phase. accessories: glass thermometer, 10 k ntc thermistor probe, k-type thermocouple probe, patch cords and user manual., cathode ray oscilloscope bandwidth: dc to 30 mhz (-3 db) - sensitivity: 1 mv/div to 5 v/div - display modes: ch1, ch2, dual (chop/alt), add, sub - timebase: 0.2 s/div to 0.5 s/div (essential for slow bio-signals) - magnification: x 10 sweep magnifier - triggering: alt triggering, auto, norm, - tv-v/h with source selection (ch1, ch2, line, ext). - input impedance: 1 mohm || 25pf - included accessories: two 60 mhz passive probes, power cord, and user manual
Tender For provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) watertemperaturegauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti
Tender For supply of replacement damped vacuum tank door spring part no 32752 , upgrade kit for damped vacuum tank front door spring assembly part no 32753 , upgrade kit for damped vacuum tank back door spring assembly part no 32754 , load unit water distibutor manifold part no 31622 , load unit air and water manifold part no 31604 , active pirani rough vacuum gauge part no gauge101 , active magnetron high vacuum gauge part no gauge102 , active pirani gauge replacement tube part no gauge101a , supernut assembly part no hn100 , 3 by 4 inch 10 x 8 inch hhb grade 9 bolt part no 33929 , 3by 4 inch flat l9 washer part no hn030 , jack screw for mcu supernut assembly part no hn101a , superbolt lubricant part no hn101b , flat hot grips inch stainless 5mm spring pin 3 point 0mm to 4 point 25mm set of 4 pcs part no 9016 030 , round grips inch full contact stainless steel 10mm set of 4 pcs part no 9065 100 , round grips inch full contact stainless steel 6 mm set of 4 pcs part no 9065 060 , round grips inch partial contact stainless 6mm set of 4 pcs part no 9060 060 , round grips inch partial contact stainless 10mm set of 4 pcs part no 9060 100 , round grips inch full contact cu alloy 6 mm set of 4 pcs part no 9000 060 , graphite foil punch 3 by 4 inch diameter part no tool012 , punch pad for foil punch part no tool011 , automatic specimen loading tool part no 32782 , specimen loading clip for plane strain specimens 10mm x 15mm x 20mm part no 33780 , specimen loading clip for flow stress specimens 10mm diameter x 9mm length minimum part no 33782 , specimen loading clip for flow stress specimens 8mm diameter x 10mm length minimum part no 33795 , specimen loading clip for flow stress specimens 6mm diameter x 9mm length minimum part no 33796 , iso t uniaxial compression anvil cap high temperature part no 9220 069 , low force wedge jaw assembly part no 9510 101 , replacement transducer assembly for 39050 and 39052 jaw to jaw l strain assembly 1 by 2 inch travel part no ga000192 , hydrawedge ii l strain system part no 39057 , cct dilatometer assembly with lvdt transducer part no 9655 001 , universal extensometer mount part no 9655 100 , fine wire thermocouple welder rebuild kit part no 35202 , cct dilatometer tygon tubing 1 by 16 in id x 3 by 16 in od part no tu314 , thermocouple single hole ceramic insulating tubes set of 5 part no tc007 , double hole round ceramic thermocouple insulator part no tc026 , clear teflon tc insulator tubing part no tu010 , black teflon tc insulator tubing part no tu011 , thermocouple red push post part no g176b , thermocouple black push post part no g176c , replacement 110 silicon o ring part no ors110 , normally open dump valve c10 2 cavity part no vlv104 , normally close dump valve c10 2 cavity part no vlv105 , load cell calibrator spherical washer set 0 point 75 inid x 1 point 630 inod x 0 point 38 in thk blk part no wa0750 01