Web Analytics Made Easy - StatCounter

Water Channel Repair Tenders

Get complete information related to latest Water Channel Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Channel Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Channel Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :43144742 Due date: 01 Jan, 202601 Jan, 2026 74.32 Lacs
Tender For supply of supply of 16 channel nvr , supply of 55 inch display , supply of cat6 utp cable , supply of 10tb hdd , supply of 8 port poe switch , supply of 6u indoor rack , supply of 2 mp dome type ip indoor camera , supply of 5 mp bullet type ip outdoor camera , supply of 2 mp ptz type ip outdoor camera , supply of 25mm dia pvc waterline pipe , supply of 1kva online ups , supply of single-mode 6-core optical fibre cable outdoor type , supply of media converter , supply of rf link , itc of scctv management system , supply of accessories required for 6 core single mode fiber cable , 1st year camc charges , 2nd year camc charges , 3rd year camc charges , sitc of 12 port l3 external netwok switch , supply of cat 6a copper conductor outdoor utp cable , supply of 15ru outdoor equipment rack , supplying and laying of 63mm dia dwc hdpe pipe , cutting with machine in bituminous or cement concrete , supply of full hd optical zoom 33x 2 mp ptz type ip outdoor camera , supply of 2 mp fixed type ip outdoor camera , supplying and fixing of 4 mtr height gi octogonal pole , charges for providing necessary vms application license , supply and laying of cable of size 3 core x 4 sqmm frls copper conductor xlpe , providing and fixing 75mm dia gi pipe b class , itc of above items of scctv management system at nitb entrance

CTN :43033958 Due date: 17 Dec, 202517 Dec, 2025 NA
Tender For corrigendum : the work of shifting of line full deposite scheem at various place under edd-sadabad hathras. - safe carriage of following material from electricty store center hts to pit site of work through the kacha and pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, t&p, etc. which required for proper completion of work.(distance 00-50 kms.), 8.5/9 mtr. long pcc poles., 9/11 mtr. s.t. poles, acsr weasel conductor, earthing complete, shackle insulator, stay set complete, teoff channel, 33/11 kv pin insulator with pin, disc insulator with disc fitting, f bracket, 11 kv x-arm, 50/95/120 sqmm. ab cable, suspension clamp, dead end clamp, distribution box with clamp, pearcing connector, guarding angle with clamp, g.i wire 6/8/10 swg, neutral cum earth wire, cable jointing kit, 11 kv xlpe cable, 25 kva t/f, 63 kva t/f, 100 kva t/f, errection of following poles including cutting of kharanja/mettalic road/concrete portion while digging pit & complete h.t./l.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t&p and carrier etc. required for proper completion of work., pcc poles 8.5/9 mtr., stp 9.0/11 mtr., errection and grouting of stays as per respo norms and as per direction of supervising engineer. grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost., fixing of earthing rod as per respo norms and as per direction of supervising engineer., safe installation of following new/repaired cousted t/f on newly constructed double pole in proper alignment direction & making all ht/lt connection., 25 kva t/f, 63 kva t/f, 100 kva t/f, laying, sagging and stringing and jumpering / binding etc. of new & old acsr weasal conductor / gi in 11 kv / lt lines as per respo manual and as per direction of supervising engineer., acsr weasal conductor, 50/95/120 sqmm. ab cable, xlpe cable, providing & fixing of following clamps, 11 kv x arms clamps for stp/pcc pole, nut,bolt & washer, 11 kv f clamp for stp/pcc pole, earthwire clamps, lt clamp with nut & bolt, cable jointing kit, cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer, guarding/reguarding of 11 kv line by laying, stringing, sagging and binding of 2 nos. parallel gi wire 6 swg after providing, fabrication and fixing of guarding angle and fabrication and fixing of x-guards (tillis) of gi wire at distance of 3 mtr., installation of extra t on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, t&p etc, required for proper completion of work. the "t" pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of material., dismentlling and removal of existing line from the various area, dismentlling of pole stp/pcc, back cartage, acsr weasel conductor scrap, iron scrap

CTN :42685896 Due date: 12 Dec, 202512 Dec, 2025 NA
Tender For bid to ras supply of proc of misc items for maint of op wks assets at mh d d--steel roofing trough 6 feet srt , steel roofing trough 8 feet srt , indian standard medium beam 250mm x 125mm x 5701mm long , indian standard medium beam 250mm x 125mm x 5120mm long , 12mm dia tmt bar , 8mm dia tmt bar , ldpe film , nonskid virified ceramic tiles , chequered cement concrete tiles , hdpe sand bags , cement of 43 grade , crushed stone aggregate 20mm , crushed stone aggregate 40mm , fine aggregate sand coarse , cement concrete solid bricks , hardcore 40 to 63mm broken boulder stone , cement base paint , obd , primer interior , primer exterior , synthetic enamel paint , red oxide , water proofing compound , precast pcc block , precast manhole cover 750mmx400mmx65mm , water storage tank 1000ltr , ventilator 600mm x 450mm , aluminium door two leaf 1200mm wide , mild steel cast iron 25mm floor channel , float valve brass 20mm , upvc 15 mm pipe , upvc 20 mm pipe , upvc coupler 15 mm , upvc coupler 20 mm , upvc elbow 90 degree 15 mm , upvc elbow 90 degree 20 mm , upvc reducing elbow 90 degree , upvc equal tee 15 mm , upvc equal tee 20 mm , upvc reducing tee , upvc end cap 15 mm , upvc end cap 20 mm , upvc union 15 mm , upvc union 20 mm , upvc male threaded adopter 15 mm , upvc male threaded adopter 20 mm , upvc female threaded adopter 15 mm , upvc female threaded adopter 20 mm , upvc female threaded tee 15 mm , upvc female threaded tee 20 mm , upvc female threaded elbow brass , upvc female threaded elbow 20 mm , upvc male threaded adapter 15 mm , upvc male threaded adapter 20 mm , upvc female threaded adapter 15 mm , upvc female threaded adapter 20 mm , upvc pipe clip plastic 15 mm , upvc pipe clip plastic 20 mm , upvc tank connector 20 mm , teflon tape , upvc solvent , eco drain pipe , pvc swr coupler 160 mm dia , pvc swr single tee , pvc swr grating 110mm , pvc swr 110mm nahani trap , pvc swr bend with inspection door , pvc swr bend 110mm diameter , pvc swr 110mm socket or connector , pvc swr pipe 110mm dia , pvc swr pipe 75mm dia , pvc swr cowl 75mm dia , rubber lubricant for swr pipe , pvc swr 75 mm bend , pvc swr tee 75 mm , pvc swr clamp for holding of 75 mm dia pipe , pvc swr clamps for holding of 110 mm dia pipe , frp septic tank , frp soakage pit , stop valve fancy type , ss sink , ss sink with drainage board //bid details2 / 65

State Government

CTN :43136142 Due date: 20 Jan, 202620 Jan, 2026 1.55 Lacs
Tender For construction of concrete channel from dipak jana hause to tapan samai at chhennyagar gram sansad no haur viii place j l no 150 plot no 797

State Government

CTN :43117149 Due date: 23 Dec, 202523 Dec, 2025 3.00 Lacs
Tender For r and r work for providing drainage channel and cement concrete flooring at tower no. 75 of 400kv dehar-panchkula transmission line.

Central Government/Public Sector

CTN :43111326 Due date: 30 Dec, 202530 Dec, 2025 NA
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim

State Government

CTN :43128103 Due date: 16 Dec, 202516 Dec, 2025 1.45 Lacs
Tender For protection of spillway channel towards basati nallah rd 123 to 130 m by providing wire crate wall and cement concrete work which was damaged due to heavy rainfall during monsoon 2025

CTN :43037356 Due date: 11 Dec, 202511 Dec, 2025 NA
Tender For the work of construction of line and other associate work under full deposite scheme at various place under eudd-hathras. - safe carriage of following material from electricty store center hts to pit site of work through the kacha and pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, t&p, etc. which required for proper completion of work.(distance 00-50 kms.), 8.5/9 mtr. long pcc poles., 9/11 mtr. s.t. poles, acsr weasel conductor, earthing complete, shackle insulator, stay set complete, teoff channel, 33/11 kv pin insulator with pin, disc insulator with disc fitting, f bracket, 11 kv x-arm, 50/95/120 sqmm. ab cable, suspension clamp, dead end clamp, distribution box with clamp, pearcing connector, guarding angle with clamp, g.i wire 6/8/10 swg, metering cubicle, ct-pt, 11 kv xlpe cable, 25 kva t/f, 63 kva t/f, 100 kva t/f, errection of following poles including cutting of kharanja/mettalic road/concrete portion while digging pit & complete h.t./l.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t&p and carrier etc. required for proper completion of work., pcc poles 8.5/9 mtr., stp 9.0/11 mtr., errection and grouting of stays as per respo norms and as per direction of supervising engineer. grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost., fixing of earthing rod as per respo norms and as per direction of supervising engineer., safe installation of following new/repaired cousted t/f on newly constructed double pole in proper alignment direction & making all ht/lt connection., 25 kva t/f, 63 kva t/f, 100 kva t/f, fixing/ errection of following item, cost of labor, material and t&p which required for completion of work, teoff channel, 33/11 kv pin insulator with pin, disc insulator with disc fitting, f bracket, 11 kv x-arm, suspension clamp, dead end clamp, distribution box with clamp, pearcing connector, metering cubicle, ct-pt, laying, sagging and stringing and jumpering / binding etc. of new & old acsr weasal conductor / gi in 11 kv / lt lines as per respo manual and as per direction of supervising engineer., acsr weasal conductor, 50/95/120 sqmm. ab cable, xlpe cable, providing & fixing of following clamps, 11 kv x arms clamps for stp/pcc pole, nut,bolt & washer, 11 kv f clamp for stp/pcc pole, earthwire clamps, lt clamp with nut & bolt, cable jointing kit, cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer, guarding/reguarding of 11 kv line by laying, stringing, sagging and binding of 2 nos. parallel gi wire 6 swg after providing, fabrication and fixing of guarding angle and fabrication and fixing of x-guards (tillis) of gi wire at distance of 3 mtr., installation of extra t on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, t&p etc, required for proper completion of work. the "t" pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of material., dismentlling and removal of existing line from the various area, dismentlling of pole stp/pcc, back cartage, acsr weasel conductor scrap, iron scrap

corporations/Associations/Others

CTN :43110510 Due date: 16 Dec, 202516 Dec, 2025 NA
Tender For work no 2 kmc pr kr 35 yadavnagar antargat kaleghar te sontakke ghar rcc channel tasech drenege line va pinyache pipe line takane va passage concrete karne

corporations/Associations/Others

CTN :43082810 Due date: 20 Dec, 202520 Dec, 2025 NA
Tender For supply of 4500nos of stay set complete - supply of silicagel blue, 0.6kva ups, stay set complete( quote price for single unit only), silicagel blue 10 to 12mm, pole pit for 9.0m and 9.14 m psc/rcc / all metal poles (each pit) 1.25 x 0.6 x 1.83 mtr, ordinary soil, semi rocky soil, heavy rocky soil where blasting/ cheseling required [specific approval should be obtained from concerned ee], stay pit, in ordinary soil [0.95 x 0.6 x 1.2m], semi rocky soil, stay pit in heavy rocky soil where blasting/ cheseling reqiured [specific approval should be obtained from concerned ee], erection of poles & stays (including refilling of excavated earth), erection of 7.5m / 8.0m poles [rcc / psc], erection of 9.00m / 9.14m rcc / psc/rail pole, tubular pole and all metal poles, stay set, erection stay set complete, stay erection without rod and pit, replacement of stay rod only. (including stay pit excavation & refilling & erection), replacement of guy shackle only in existing stay, erection of line materials, fixing of lt 1 ph "x" arm, fixing of lt/ht ti fitting, fixing of lt 3 ph "x" arm, fixing of 3[1/2] v ` x arm, fixing of 4[1/2] v ` x arm, fixing of 5 v x arm, fixing of tapping channel / guarding "x" arm, providing of line spacers in lt lines 1 phase, providing of line spacers in lt lines 3 phase, erection of ab switch with pt insulator & jumpering complete, erection of centre rotating switch ab switch complete, fixing of ht pin insulator / strain disc, 11 kv pin insulator with pin, 11 kv strain disc / polymer disc with hardware, 22 kv pin insulator with pin, 22 kv strain disc / polymer disc with hardware, 33 kv pin insulator with pin, 33 kv pin strain disc/polymer disc with hardware, fixing of lt pin insulator with pin, lt shakle with hardware, fixing of aluminium knob, paving stringing and sagging of conductor including binding of pin and proper tight [including transport of condutor from road side to work spot] per run, upto 7/2.59 mm acsr, 7/2.50 aaac including pvc cable upto 25 sqmm, acsr 7/3.35mm & 7/ 3.15 aaac including pvc cable above 25 sqmm, acsr 7/4.09 mm, above 7/4.09 mm acsr & dog conductor, earthing wiring and connection including transporting of earth pipe and excavation of pit], transformer structure earthing 10ft depth - 3 nos of pipe through tubes, dp earthing including all works [double side earthing], erection of 4th earth pipe including earthing, earthing of poles, earth pit masonary work 3 nos earth pits or using 3 nos concrete tub., replacement of detoriated earth pipe per location, concreting with mixture 1:3:6 [including all materials]., mass concreting for centre support for 2 feet including all materials, mass concreting for pole0.6x0.6x1.25m.with coping, sleeve concreting for pole 0.6 m x 0.6m x 0.3 m with coping, sleeve concreting for stay set 0.3 m & 0.75 long, erection of distribution transformer structure complete, excavation of structure pole pits 0.9 x 0.9 x 1.83 mtr, transporting of pole to pit location 2 nos., erection of poles 2 nos, excavation of stay pit 4 nos, erection of stay set (4 sets), mass concreting (cement:sand:jelly supplied by the contractor) 2 nos., erection of 22 kv ab switch, ttransformer structure earthing 10ft depth - 3 nos of pipe through earth tubes, erection of top channel, bed channel [2 nos channel] erection, cross with stud for bed channel erection, erection of belting angle / hg fuse angle, erection of hg fuse set, erection of ht las with jumpering and earthing, erection of lt las with jumbering and earthing, erection of jumpering [ht side], transformer wiring in lt side including jumpering bus bar etc., erection lt open type fuse unit arrangement single, erection lt open type fuse unit arrangement double, painting of stru. complete excluding dt [two coat of red oxide] all metal parts(excluding cost of paint)., painting of stru. complete excluding dt [one coat alu paint, excluding cost of paint), colour washing of 2 numbers structure pole [excluding c
 Loading, Please wait...

Connect us via What's Up