Get complete information related to latest Water Gutter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Gutter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Gutter Tenders.
Tender For removal of blockage of sewage line including necessary repair and dewatering sludge removal from septic tank and disposal of officers jcos and ors md accn under age br ii under ge w mathura
Tender For cleaning, sanitation, up keeping, maintenance and removal of garbages, beehives of upper kolab power house and its area, switchyard control room & its area, all stores, garage & its area, power house canteen, valve house & its area, surge tank area, workshop, penstock area, sewage system of ukhep, residential & nonresidential buildings of ukhep, bariniput & power house colony on job contract basis for a period of 12 calendar months
Tender For lwlrrm shell kit (a) lwlrrm - roof, sidewall and end wall one coach set of roof, 2 mm side wall and end wall for lwlrrm coaches with noise reduction feature 1) roof c omplete to drg. no. 53816018, alt 'c' - 1 no 2) final roof element to drg. no. 83416016, alt ' a'-1 no 3) roof end part complete to drg. no.83416017, alt 'a' -1 no 4) end roof assy to drg no. 58116066, alt 'g' - 1 no, 5) ss trough arrangement to drg no. 53816023 alt 'a'- 1 no 6) side wall right complete to drg. no. lp14110, alt a anx. 6 -1 no 7) side wall left complete to drg.n o. lp14111, alt a anx.6 -1 no 8) sidewall npp-end right complete to drg.no.1.10113.0.20.110. 004, alt b anx.3 -1 no 9) side wall coach end complete to drg.no. 1.10113.0.20.110.003, alt b anx.4 -1 no 10) side wall pp end left cpl to drg.no. 1.10113.0.20.110.005, alt nil anx.3 -1 n o 11) side wall pp end right cpl to drg .no. 1.11012.0.20.110.003, alt nil anx.3 -1 no 12) end wall complete for lhb power car to drg. no. 1.11012.0.20.120.003, alt a anx.9 - 1 no with l atest detail drgs 1.11012.0.20.120.004-alt b anx-4 and mi007721_a_anx-2 13)end wall compl ete for lhb power car to drg. no. lp15103, alt nil anx-2 -1no 14) door cut out to drawin g no. lr10295-1 no & lr10296, alt a-1 no, 72914089, alt c- 1 no, 729 14 091, alt c- 1 no, 15) car l ine nos 1.11012.0.20.110.007, alt r - 1 no and 1.11012.0.20.110.008, alt r - 1 no. the end wall sha ll be assembled with cover sheet and shutter complete to item no.1 & 2 of drg.no.3.1011 3.0.20.120.183, br and item 6,7,8,10,12 of drg.no.2.10113.0.76.300.002, alt c and tail lamp br acket to drg no.2.10113.0.10.300.001. the firm shall fulfill the requirement as per.icf/md/ specn.200, issue status-01, rev-04 with amendment no-01. for end wall the firm shall fulf il the requirement as per icf/md/spec-315,issue status-01, rev.00. firm has to supply roof and sidewall without applying etch primer and the firm has to apply etch primer on roof and sidewall in icf after shell assembly. (b) body shell items & partitions for lwlrrm shell kit supply and insta llation of body shell items and partition frames for lwlrrm coaches to drg. no. 1) aaa1 0488, alt. c- 2 nos (rain watergutter) 2) 2 11012.0.20.110.100, alt.nil-2 nos.(rain watergutter) 3) lp 10107, alt. nil - 2 nos,(sheeting) 4) lp10136, alt d anx-4 -1no. (welding parts car body) 5) lp10125 alt b anx-10, item-33 - 14 nos.(ledge) 6) lp10108, alt a anx-1- 8 nos.(duct assy) 7) aaa10278, alt . nil-4 nos.(hand hold arrangement) 8) 1.11012.0.03.095.001 alt a -1 no (w/p in u/f incl. 53810070 & 53810035) 9) lp10139, anx-5 - 1 no (partition frames) the above items to be supplied as set and install the same at the body shell assembly stage to assembly drg.no. lp10125, alt b anx -10 (c) under frame arrangement -613-lp11103 alt 'd' anx-7 the manufacturing facility as pe r icf/md/spec-147, issue status-01 rev.02 with amendment no.01 special condition : a) -packin g as per icf/j&t/misc-2201, alt 'e', safety instruction as per icf/j&t/sk-1867, alt. 'nil' -packin g as per icf/j&t/sk-1809, alt 'a'. b) - packing condition as per icf/j&t/sk-1865, alt "a". installa tion required as per assy.drg.& annexure-a, dtd 13-09-2023 to be followed. supply rates a nd installation rates to be quoted separately. c)packing condition as per drg.no.icf/j&t /misc-2487, alt 'b' the underframe should be supplied as normal side up and side bearer s ide down. [safety item ]
Tender For operation of electrical and mechanical equipment including removal and disposal of chocking materials garbage etc. at 09 mld allahpur sewage pumping station, prayagraj
Tender For operation of electrical and mechanical equipment removal and disposal of choking materials garbage etc. at 80 mld alopibagh sewage pumping station, prayagraj.
Tender For corrigendum : providing of custom bid for services - outsourcing of service for mechanised desludging and cleaning of man holes septic tanks including sewage and blockage removal at cfa
Tender For corrigendum : development of chikkabelandur lake by enhancing storage capacity of lake through desilting and removal of slush, construction of wetland, sewage diversion drain, installation of sluice gate, water body protection and other allied works
Tender For development of chikkabegur lake by constructing wetland areas, increasing storage capacity of lake through desilting and removal of slush, sewage diversion drain, water body protection and other allied works