Get complete information related to latest Water Line Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Line Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Line Repair Tenders.
Tender For mc ew d rob to up-gradation and maintenance of drainage system including sewer and waste water pits soil pipes csu manholes and fixtures for toilet etc at pt dduia greater noida
Tender For construction of model registry office (i/c water supply ,septic tank ,rain water harvesting ,borewell and internal electrifictaion with computer networking i/c ups system ) for sub registrar office balod, distt.-balod (c.g.)
Tender For providing of customized amc/cmc for pre-owned products - comprehensive annual maintenance contract of 01 no of water purification system; make ion exchange india ltd with model indion labq ultra type i 10 lph and sl no nu00921906180001 make ion exchange india lt..
Tender For repairing of chimney and arrangement made for protection of one number multi-circuit tower and three number dd0 tower along with construction of drainage system to drain the water premises under jurisdiction of 132/33 kv gss, jadugoda
Tender For construction of new borewell system for ground water recharge at different villages of bagasara taluka of amreli district during year 2025-26 (mla jal sanchay grant)
Tender For turnkey assignment of design, engineering, manufacturing, supply, erection, installation and commis - "asme section-viii, div-1 applicable, 500l(as per sl no. 1 of annexure i)", "asme sec. viii div. i edition 2021 & gep norms applicable, 500l ss316l(as per sl no. 2 of annexure i)", "asme sec. viii div. i edition 2021 & gep norms applicable, 250l ss316l(as per sl no. 3 of annexure i)", "asme sec. viii div. i edition 2021 & gep norms applicable, 250l ss316l, (high vacuum distillation system)(as per sl no. 4 of annexure i)", "asme sec. viii div. i edition 2021 & gep norms., 500l ss316l(as per sl no. 5 of annexure i)", "asme section-viii, div-1 applicable, 250l msgl(as per sl no. 6 of annexure i)", "asme section-viii, div-1 applicable, 100l msgl(as per sl no. 7 of annexure i)", "glass distillation assembly(as per sl no. 8 of annexure i)", "centrifuge, 24"" with halar, 100l ml tank with aodd pump- 5 m3/hr and 20 m head.(as per sl no. 9 of annexure i)", "asme sec. viii div.i, edition 2021 applicable(as per sl no. 10 of annexure i)", "asme sec. viii div.i, edition 2021 applicable(as per sl no. 11 of annexure i)", "asme sec. viii div.i, edition 2021 applicable(as per sl no. 12 of annexure i)", "asme sec. viii div.i, edition 2021 applicable(as per sl no. 13 of annexure i)", "sparkler filter with skid and pump with zero holdup 14 inch (as per sl no. 14 of annexure i)", "pressure nutsch filter- 100 liters(as per sl no. 15 of annexure i)", "vibro shifter 24”(as per sl no. 16 of annexure i)", "vibro shifter 24”(as per sl no. 17 of annexure i)", "multi mill 1 hp motor gmp model(as per sl no. 18 of annexure i)", "multi mill 1 hp motor gmp model(as per sl no. 19 of annexure i)", "msgl receiver 500l for all reactor common addition(as per sl no. 20 of annexure i)", "msgl receiver 500l for all reactor common addition(as per sl no. 21 of annexure i)", "blender with multi-product basket- octagonal blender 200 ltrs, gross capacity (gmp) model, all powder contact parts ss316l(as per sl no. 22 of annexure i)", "tcu (-35 to 250 deg c) suitable for 50l or 100l glass reactors(as per sl no. 23 of annexure i)", "heating circulator(as per sl no. 24 of annexure i)", "thermic oil (-) 45 deg c to 250 deg c , material silicon oil .(as per sl no. 25 of annexure i)", "thermic oil rt to 300 deg c. material silicon oil (as per sl no. 26 of annexure i)", "cooling tower frp, frp moulded counter flow , total capacity 160 tr, total water flow 97 cmh. (as per sl no. 27 of annexure i)", "electrically heated boiler(as per sl no. 28 of annexure i)", "brine chiller cooling(as per sl no. 29 of annexure i)", "nitrogen gas generator(as per sl no. 30 of annexure i)", "reputed make air compressor(as per sl no. 31 of annexure i)", "vacuum pumps dry (as per sl no. 32 of annexure i)", "two stage water ring vacuum pump(as per sl no. 33 of annexure i)", "vent -scrubbing system(as per sl no. 34 of annexure i)", "purified water plant –ro tds, 50 ppm inlet, tds below 1 ppm outlet, 500 lph with 2 kl storage tank with scada and pc(as per sl no. 35 of annexure i)", "process pumps- magnetic 2m3/hr , 20 meter head- 3 nos. (flp) pvdf(as per sl no. 36 of annexure i)", "process pumps- magnetic 2m3/hr , 20 meter head- 3 nos. (flp) ss316l(as per sl no. 37 of annexure i)", "centrifugal pump- cs-32 cum/hr (q), 35 m head- 2nos. ( reputed make)(as per sl no. 38 of annexure i)", "centrifugal pump- cs-65 cum/hr (q), 20 m head- 2nos. ( reputed make)(as per sl no. 39 of annexure i)", "centrifugal pump- cs-24 cum/hr (q), 35 m head- 2nos. ( reputed make)(as per sl no. 40 of annexure i)", "centrifugal pump- cs-10 cum/hr (q), 20 m head- 2nos. ( reputed make)(as per sl no. 41 of annexure i)", "centrifugal pump- cs-10 cum/hr (q), 35 m head- 2nos. ( reputed make)(as per sl no. 42 of annexure i)", "dump tank connected to all reactors ss316l 1000l – 1no.(as per sl no. 43 of annexure i)", lighting (as per sl no. 44 of annexure i), "fire fighting system(as per sl no. 45 of annexure i)", "data logge