Tender For auction sale of depot ferrous scrap - scrap and condemned lhb draft gear arrangement complete of sorts & sizes, with or w/o polymer attachments ,us & ur,as it is. loc:-lying at bin no.c-42 in scrap yard judw. remarks:- (1)loading by purchaser. (2) private road crane allowed for loading purpose only.
Tender For providing of handling and transport on lumpsum basis - handling & transport service, tender no 038 cluster 01 polymer and pta road transportation ex. panipat to various destinations across the country,handling and transport on lumpsum basis - handling & transport service, tender no 038 cluster 01 polymer and pta road transportation ex. panipat to various destinations across the country,handling and transport on lumpsum basis - handling & transport service, tender no 038 cluster 01 polymer and pta road transportation ex. panipat to various destinations across the country,handling and transport on lumpsum basis - handling & transport service, tender no 038 cluster 01 polymer and pta road transportation ex. panipat to various destinations across the country,handling and transport on lumpsum basis - handling & transport service, tender no 038 cluster 01 polymer and pta road transportation ex. panipat to various destinations across the country,handling and transport on lumpsum basis - handling & transport service, tender no 03
Tender For supply of polypropylene-co- polymer(pp-cp) based container lead acid secondary cell 2volt 200 ah capacity at 10 hrs rate of discharge confirming to rdso specification no. irs: s-88/2004 with latest amendments assembled with tubular positive and pasted negative plate in polypropylene-co-polymer(ppcp) container with micro porous vent plug floats, lead coated inter cell connector nut bolts washer in dry uncharged condition. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of (i) pyrolysis test solution no:1 (rubber polymer identification) (packing 500ml pack):1 litre (ii) pyrolysis test solution no:2 (rubber polymer identification) (packing 500ml pack) 1 litre (iii) test tube (5 ml capacity) 100 pcs -02 packet (iv) bunsen burner (spirit use) cast iron base & brass pipe fitting 02 nos [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of primary belt scraper, spring-loaded, segmented polyurethane tip, ss fasteners, 1200mm belt , spare blade for primary belt scraper, polyurethane tip, ss fasteners, 1200mm belt , secondary belt scraper, sprung elastomount, tungsten carbide tip, polymer deflector plates, ss fasteners, 1200mm belt , spare blade for secondary belt scraper, tungsten carbide tip, polymer deflector plates, ss fasteners, 1200mm belt , primary belt scraper, spring-loaded, segmented polyurethane tip, ss fasteners, 1400mm belt , spare blade for primary belt scraper, polyurethane tip, ss fasteners, 1400mm belt , secondary belt scraper, sprung elastomount, tungsten carbide tip, polymer deflector plates, ss fasteners, 1400mm belt , spare blade for secondary belt scraper, tungsten carbide tip, polymer deflector plates, ss fasteners, 1400mm belt , self-adjustable internal scraper v- plough, polymer block, 1200mm belt , spare polymer blocks for internal scraper v-plough, 1200mm belt * /bid number : gem/2026/b/7563860 + /dated: 04-06-2026 ' ' / bid document 1 / 13
Tender For corrigendum : supply of 4500 sets of stay set complete - supply of silicagel blue, 0.6kva ups, stay set complete( quote price for single unit only), silicagel blue 10 to 12mm, pole pit for 9.0m and 9.14 m psc/rcc / all metal poles (each pit) 1.25 x 0.6 x 1.83 mtr, ordinary soil, semi rocky soil, heavy rocky soil where blasting/ cheseling required [specific approval should be obtained from concerned ee], stay pit, in ordinary soil [0.95 x 0.6 x 1.2m], semi rocky soil, stay pit in heavy rocky soil where blasting/ cheseling reqiured [specific approval should be obtained from concerned ee], erection of poles & stays (including refilling of excavated earth), erection of 7.5m / 8.0m poles [rcc / psc], erection of 9.00m / 9.14m rcc / psc/rail pole, tubular pole and all metal poles, stay set, erection stay set complete, stay erection without rod and pit, replacement of stay rod only. (including stay pit excavation & refilling & erection), replacement of guy shackle only in existing stay, erection of line materials, fixing of lt 1 ph "x" arm, fixing of lt/ht ti fitting, fixing of lt 3 ph "x" arm, fixing of 3[1/2] v ` x arm, fixing of 4[1/2] v ` x arm, fixing of 5 v x arm, fixing of tapping channel / guarding "x" arm, providing of line spacers in lt lines 1 phase, providing of line spacers in lt lines 3 phase, erection of ab switch with pt insulator & jumpering complete, erection of centre rotating switch ab switch complete, fixing of ht pin insulator / strain disc, 11 kv pin insulator with pin, 11 kv strain disc / polymer disc with hardware, 22 kv pin insulator with pin, 22 kv strain disc / polymer disc with hardware, 33 kv pin insulator with pin, 33 kv pin strain disc/polymer disc with hardware, fixing of lt pin insulator with pin, lt shakle with hardware, fixing of aluminium knob, paving stringing and sagging of conductor including binding of pin and proper tight [including transport of condutor from road side to work spot] per run, upto 7/2.59 mm acsr, 7/2.50 aaac including pvc cable upto 25 sqmm, acsr 7/3.35mm & 7/ 3.15 aaac including pvc cable above 25 sqmm, acsr 7/4.09 mm, above 7/4.09 mm acsr & dog conductor, earthing wiring and connection including transporting of earth pipe and excavation of pit], transformer structure earthing 10ft depth - 3 nos of pipe through tubes, dp earthing including all works [double side earthing], erection of 4th earth pipe including earthing, earthing of poles, earth pit masonary work 3 nos earth pits or using 3 nos concrete tub., replacement of detoriated earth pipe per location, concreting with mixture 1:3:6 [including all materials]., mass concreting for centre support for 2 feet including all materials, mass concreting for pole0.6x0.6x1.25m.with coping, sleeve concreting for pole 0.6 m x 0.6m x 0.3 m with coping, sleeve concreting for stay set 0.3 m & 0.75 long, erection of distribution transformer structure complete, excavation of structure pole pits 0.9 x 0.9 x 1.83 mtr, transporting of pole to pit location 2 nos., erection of poles 2 nos, excavation of stay pit 4 nos, erection of stay set (4 sets), mass concreting (cement:sand:jelly supplied by the contractor) 2 nos., erection of 22 kv ab switch, ttransformer structure earthing 10ft depth - 3 nos of pipe through earth tubes, erection of top channel, bed channel [2 nos channel] erection, cross with stud for bed channel erection, erection of belting angle / hg fuse angle, erection of hg fuse set, erection of ht las with jumpering and earthing, erection of lt las with jumbering and earthing, erection of jumpering [ht side], transformer wiring in lt side including jumpering bus bar etc., erection lt open type fuse unit arrangement single, erection lt open type fuse unit arrangement double, painting of stru. complete excluding dt [two coat of red oxide] all metal parts(excluding cost of paint)., painting of stru. complete excluding dt [one coat alu paint, excluding cost of paint), colour washing of 2 numbers structure p
Tender For supply, testing of 11 kv aaac triple extruded covered conductor mvcc 1c 70 sqmm xlpe cable, aaac / al-7/ al -59 shielding with semi conducting cross-linked polymer, inner covering with low-density track resistance cross-linked polyethylene (without carbon black), outer covering with high-density uv & track resistance cross-linked polyethylene, extruded semi conductive layer 0.3 mm, with inner insulation of xlpe without carbon black 1.2 mm, outer insulaton with uv & track resistant xlpe 1.1 mm as periec: 61089, is: 398-2iec: 61089, bs en: 50182/50397.make : rr/havells/finolex/kei [ warrantyperiod: 12 months after the date of delivery ] ]
Tender For supply, testing of 11 kv aaac triple extruded covered conductor mvcc 1c 120 sqmm xlpe cable, aaac / al-7/ al -59 shielding with semi conducting cross-linked polymer, inner covering with low-density track resistance cross-linked polyethylene (without carbon black), outer covering with high-density uv & track resistance cross-linked polyethylene, extruded semi conductive layer 0.3 mm, with inner insulation of xlpe without carbon black 1.2 mm, outer insulaton with uv & track resistant xlpe 1.1 mm as per iec: 61089, is: 398-2iec: 61089, bs en: 50182/50397. make : rr/havells/finolex/kei [ warranty period: 12 months after the date of delivery ] ]
Tender For supply of set of spares for transformer oil filtration plant. set consists of 04 items as follows: 1)nitrile polymer rubber o ring compound as per group c of 3.2.4.1 to irs.r 48/88 or astm d2000 / is 3400 dimensions :od-26mm,id-16mm,thickness -5mm; qty: 100 nos. 2) nitrile polymer rubber cord dia 4mm compound as per group c of 3.2.4.1 to irs.r 48/88, or astm d2000 / is 3400; qty: 10 meters. 3) nitrile polymer rubber cord dia 8mm compound as per group c of 3.2.4.1 to irs.r 48/88,or astm d2000 / is 3400; qty: 10 meters. 4) teflon washer made of virgin ptfe,conforming to astm d4894 / astm d4895 is 13708,suitable for transformer oil,temperature range -200 degree centigrade to +260 degree centigrade, excellent electrical insulation and chemical resistance. as per dimensions :inner dia-7mm,outer dia -14mm,thickness -3mm; qty:200 nos. [ warranty period: 24 months after the date of delivery ] ]