Tender For bid to ras supply of collagen wound dressing consist of collagen coma having a porous structure with highly pronounced capillary activity coma enabling , activated charcoal with silver in an antimicrobial coma flexible coma soft coma non adherent rope which contains an activated charcoal fabric impregnated with silver , super absorbent dressing coma sterile coma consists of a wound pad of rectangular shape the clothing protection coma the absorption core , phmb antimicrobial hydrobalance wound dressings act against a large spectrum of pathogens additionally coma depending on the wound condition , monofilamentous pad which absorbs exudate coma cellular debris and keratosis during debridement coma gentle on intact tissue. , antimicrobial calcium alginate wound dressing are soft and conformable wound covers with high mannuronic acid , with nano crystalline silcryst technology coma sustained release of silver for 3 days should allow fewer dressing changes polyester mesh , total hip joint replacement hip implant hybrid system consisting of cemented collarless polished triple tapered stem with 12 obliq 14 taper neck , cemented dual mobility system containing cemented stainless acetabular cup coma poly liner for 22 obliq 28 mm femoral head coma stainless steel femoral head 22 obliq 28 , uncemented dual mobility system containing uncemented ha coated acetabular cup with pags for fixation in acetabulum coma poly liner for 22 obliq 28 mm fermoral head , juncemented total hip replecement prostheses ceramic on xlpe with metaphyseal filting sleeve consisting of 1 uncemented acetabular cup optaion of small ddh cup 2 , total hip joint replacement hip implants uncemented metal on polyethylene articulation ha coated collarless femoral stem ) /bid number : gem/2025/b/6781813 * /dated: 09-11-2025 & & / bid document 1 / 17
Tender For supply of cylinder liner with joint ring,valve cap,valve tappet,push rod,banjo bolt,bush for injector,washer for sump screw,injector yoke,cup for valve spring,screw with stainer,o ring for injector,primary element,secondary element,sealing ring fuel filter,v belt cogged,cylinder head bolt,valve exhhaust,v belt cogged,piston assembly,inlet valve 4r1040,rubber hose,set bolt,set screw expansion bellow,sump screw,bolt for ex manifold,banjo bolt,washer plain,copper washer,worm drive hose clip 29 mm,worm drive hose clip,nut for adjusting screw,gasket cylinder head,cylinder head assembly,hose for water pipe,lub oil drain pipe,set of joints,set of o ring,fuel pipe fuel filter to fuel pump,leak off pipe,set of washer,washer,air cleaner element koel 6r 1080ta
Tender For supply of reverse shoulder arthoplasty implant set . specification of the item: 1 reverse shoulder arthroplasty implants system reverse modular glenoid system consisting of: 1) humeral stem 2) suture cup 3) humeral insert 4) modular baseplate 5) central screw - 1 no., peripheral screw - 4 nos. 6) glenosphere specification: 1. stem sizes 5 mm to 13 mm 2. calcium phosphate coated proximal stem. 3. 135 & 155 degree inclination angle options in one universal stem body 4. glenoid plate should be circular in shape and of diameter 24 mm 5. glenosphere should have three offset options with 5 different size options 6. posterior humeral cup offset options 7. system should support metal spacer for better ligament balancing when required. 8. humeral cup should have chamfered eyelets for better reattachment of soft tissues. 9. glenoid plate should provide multiple lateralization options (standard, +2 mm & +4 mm) 10. glenoid baseplate should have option of monoblock baseplate and modular glenoid baseplate. 11. constrained and non-constrained liner options. 12. modular central screw gets attached to the baseplates via taper connection.
Tender For corrigendum : tender for rate contract of orthopedic arthroplasty implants - arthroplasty implants, basic high flex total knee replacement system: total condylar posterior stabilized (ps)/ cruciate retaining (cr) design anatomic femoral component of various sizes and having design to accommodate high flexion, can accept different sizes and thickness of fixed bearing inserts. fixed bearing cemented tibial tray in various sizes, can accept different sizes of fixed bearing inserts of various sizes & thickness. fixed bearing ps/cr polyethylene insert in different sizes & thickness compatible with various sizes of fixed bearing tibial tray. high viscosity antibiotic loaded bone cement 40 gm. with one pulse lavage system. disposable items consist of the items mentioned below: pulsatile lavage. iodinated surgical adhesive drape ( largesize ) skin stapler. cling tape. gowns (6 nos) stockinet. leg o drape, water impermeable along with screen. surgical oscillating saw blade.orthopaedic gloves with roughened palmer surface., high flex total knee replacement system with attachment of one tibal wedge and one tibial intramedullary extension rod assembly * total knee replacement system, posterior stabilized (ps), design femoral component of various sizes and having design to accommodate high flexion, can accept different sizes and thickness of fixed bearing inserts. fixed bearing cemented tibial tray in various sizes with attachment of one tibial wedge and one tibial intramedullary extension rod assembly, can accept different sizes and thickness of fixed bearing inserts. fixed bearing ps/cr polyethylene insert in different sizes & thickness compatible with various sizes of fixed bearing tibial tray. patella with pegs made of polyethylene available in various sizes. high viscosity antibiotic loaded bone cement 40 gm. disposable items consist of the items mentioned below: pulsatile lavage. iodinated surgical adhesive drape (large size) skin stapler., modular bipolar hemiarthroplasty system. modular bipolar shell containing hdpe inbuilt of different sizes (39-53mm outer diameter and 22/28 mm inner diameter in three different neck lengths). cemented tapered femoral stem (different sizes: extra small, small, medium, and large). cement restrictor centralizer 1 packet of bone cement 40 g. disposable items consist of the items mentioned below: iodinated surgical adhesive drape ( largesize ) skin stapler. cling tape. gowns (6 nos ) stockinet. leg u drape, water impermeable along with screen. ethibond5 : 1 pack with 4 threads.orthopaedic gloves with roughened surface 6 pairs., non-cemented total hip system (metal head on poly) non-cemented ha/porous coated stem having various sizes, can accept multiple offsets of metal heads (small/medium/large/extra-large) with diameter of 28/32/34/36. non cemented porous coated acetabular cup made of titanium alloy available in various sizes, with locking mechanism to accept polyethylene liner of various sizes & diameter (28/32/34/36) must have holes in dome area for screw fixation. the polyethylene liner should be highly cross-linked with various diameters & sizes compatible with acetabular cup & can accept various heads. 3 cancellous screws made of titanium to fix the cup into the acetabulum. disposable items consist of the items mentioned below: iodinated surgical adhesive drape ( largesize ) skin stapler. cling tape. gowns (6 nos ) stockinet. leg u drape, water impermeable along with screen. ethibond 5: 1 pack with 4 threads.orthopaedic gloves with roughened surface 6 pairs., non cemented total hip system (ceramic head on poly ) * non cemented ha/porous coated stem having various sizes, can accept multiple offsets of metal heads (small/medium/large/extra large) with diameter of 28/32/36. ceramic heads (made of delta ceramic) having variable offset (small/medium/large/extra large) with diameter of 28/32/36 mm compatible with the stem. non cemented porous coated acetabular cup made of titan
Tender For providing orthopedic implants at guru gobindsingh government hospital, jamnagar (part-4) - austin-moores prosthesis-37 to 53mm; stem size shall be small to large along with increase in size of the head, each, 711, uncemented femoral stem titanium, molybdenum, zirconium composite with 40 neck various sizes (gamma sterile); 127* neck shaft angel; with triflanged cenraliser, tapered-flat wedge design, ha coating with plasma spray technology. minimum 10 years clinical experience., each, 715, modular bipolar head for above stem with 12/14 taper sizes 22 and 28 mm with possibility of size adjustment of minimum +12mm, each, 719, cemented long stem for total hip replacement/ modular bipolar with v40 neck angle, double taper stem with triflanged centraliser size 240 & 260 mm, each, 723, modular bipolar cemented 12/14 taper highly polished high nitrogen (wrought nitrogen strengthened) ss femoral stem with dual taper and non winged centraliser of various diametres, various sizes. must be compatible with high nitrogen head., each, 727, modular bipolar cup for above head with anti varus dynamics and intergretad liner design, uhmwpe, pre sterile, with minimum 5mm liner thickness anywhere, allowing head 22 and 28mm, large size range from minimum 39 to 53mm, per op assembly with head prior to insertion. system should allow trial at broach and stem level both. polyethylene liner in the cup should be designed as an integral single piece construct, securely encased in its outer metal shell. the cup should be self centering ability., each, 731, uncemented total hip system modular type-cancellous titanium screw 6.5mm-20 to 50mm (gamma sterile), each, 735, modular uncemented thr acetabular shell of titanium with asymmetric titanium coating, with minimum 3 screw holes allowing liner with 28/32/36 mm head with oxidized zirconium, various sizes (large range 46 to 64mm diameter), each, 739, modular uncemented thr, oxidized zirconium femoral head for 12/14 neck, various diametres of 28,32,36mm; allowing size adjustment from -3 to +11mm or more., each, 743, screw for uncmented cup(us fda approved),hexagonal head,size 6.5mm, various length.minimum 15 years of clinical experience., each, 747, dual mobility uncmented cup titanium alloy ,with 5 hole,ha coated with plasma spray various sizes, each, 751, dual mobility joint cup screw with hexagonal head 6.5mm various sizes, each, 755, cemented total hip replacement system with proven record of more than 10 years modular femoral head v40 neck, 28 mm diametre, various sizes and bone cement, each