Get complete information related to latest Water Testing Kit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Testing Kit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Testing Kit Tenders.
Tender For 250 kva diesel generator set with amf control panel, power generator installation configuration as defined in cpwd general specifications for electrical works-part-vii (dg set) -fixed (power generators are permanently installed), nominal rated capacity (kva)-250, rated engine power(kwa)- 110% of the required powered at stp (standard temperature pressure) i.e equal ? to (nominal rated capacity (kva) of power generator any auxiliary power consumption by the power generator) x power factor (0.8)/alternator efficiency , type of governor-electronic, rated rpm of engine(rpm)-1500, fuel-high speed diesel (hsd),control panel-amf control panel , installation- with installation-inclusive in the scope of supply, warranty on complete power generator/dg set-24 months , no . of phase- 3, number of cylinders-6,starting voltage-24, type of alternator-brushless, fuel tank capacity- 600 liter, battery capacity(ah)-100,no. of battery2, testing report available for (test/approval)-type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb,cop certificate for engine type test report and endurance test report for engine as per is :10001 latest/ls:10002 latest,type test report for alternator as per is : 13364 (part-1) latest/is: 13364 (part-2) latest to prove conformity to the specification , make-cummins power, greaves, kirloskar or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : 250 kva diesel generator set with amf control panel, power generator installation configuration as defined in cpwd general specifications for electrical works-part-vii (dg set) -fixed (power generators are permanently installed), nominal rated capacity (kva)-250, rated engine power(kwa)- 110% of the required powered at stp (standard temperature pressure) i.e equal ? to (nominal rated capacity (kva) of power generator any auxiliary power consumption by the power generator) x power factor (0.8)/alternator efficiency , type of governor-electronic, rated rpm of engine(rpm)-1500, fuel-high speed diesel (hsd),control panel-amf control panel , installation- with installation-inclusive in the scope of supply, warranty on complete power generator/dg set-24 months , no . of phase- 3, number of cylinders-6,starting voltage-24, type of alternator-brushless, fuel tank capacity- 600 liter, battery capacity(ah)-100,no. of battery2, testing report available for (test/approval)-type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb,cop certificate for engine type test report and endurance test report for engine as per is :10001 latest/ls:10002 latest,type test report for alternator as per is : 13364 (part-1) latest/is: 13364 (part-2) latest to prove conformity to the specification , make-cummins power, greaves, kirloskar or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of pn or zener diode or led characteristics apparatus , verification of kcl and kvl , resistance in series and parallel apparatus , ohms law apparatus without power supply , ohms law apparatus with aluminum panel 2 digital panel meters and power supply , transistor characteristics apparatus , fet characteristics apparatus , half wave full wave and bridge rectifier apparatus , ripple factor apparatus , digital logic trainer , verification of truth table of logic gates using universal gates , flip flops using nand gates and ttl ics , four bit counters synchronous and asynchronous , four bit shift registers , encoder or multiplexer eight to one line , decoder or demultiplexer one to eight line , four bit analog to digital convertor , four bit digital to analog convertor , light intensity or phase control using scr or triac , scr commutation techniques , switching action of a bjt , single phase half wave full wave and fully controlled bridge rectifier or convertor using scrs , three phase half controlled bridge converter with r and rl load , three phase fully controlled bridge converter with r and rl load , single phase cycloconverter , instrumentation trainer using transducers , burdon tube pressure gauge trainer kit , strain gauge trainer kit with cantilever beam , lvdt trainer kit , speed measurement using photo electric and magnetic sensors , temperature sensors kit , measurement of water level using strain gauge , measurement of water level using capacitance transducer , ac servo speed torque characteristic trainer , dc servo motor speed torque characteristics trainer , stepper motor controller trainer , analog lab trainer bread board model , digital lab trainer bread board model , plc trainer , transmission line trainer abcd t and pi parameters ferranti effect load test , idmt over current relay testingkit electromechanical type , buchholz relay testingkit with compressor and oil , over voltage relay testingkit electromechanical type , over current and earth fault relay testingkit three phase static type , over current relay testingkit static type , measurement of power and power factor single phase and three phase , to study a typical bhk house wiring , four to one multiplexer and one to four demultiplexer , vapour compression refrigeration vcr test rig , water cooler setup , air conditioning test rig , domestic refrigerator , window air conditioner , split air conditioner , air cooler evaporative , tube cutter , pipe bender , flaring and swaging tool kit , reamer , brazing torch , manifold gauge set , vacuum pump , refrigerant recovery unit , refrigerant charging cylinder or electronic charging scale , refrigerant leak detector , digital clamp meter , digital thermometer , anemometer , tachometer , insulation material , refrigerants , recovery cylinders , weighing machine , electrical control panel , work benches , safety equipment
Tender For 62.5 kva diesel generator set with amf control panel, power generator installation configuration as defined in cpwd general specifications for electrical works-part-vii (dg set) -fixed (power generators are permanently installed), nominal rated capacity (kva)-62.5, rated engine power(kwa)- 110% of the required powered at stp (standard temperature pressure) i.e equal ? to (nominal rated capacity (kva) of power generator any auxiliary power consumption by the power generator) x power factor (0.8)/alternator efficiency , type of governor-electronic, rated rpm of engine(rpm)-1500, fuel-high speed diesel (hsd),control panel-amf control panel , installation- with installation-inclusive in the scope of supply, warranty on complete power generator/dg set-24 months , no . of phase- 3, number of cylinders-4,starting voltage-12, type of alternator-brushless, fuel tank capacity- 165 liter, battery capacity(ah)-100,no. of battery-1, testing report available for (test/approval)-type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb,cop certificate for engine type test report and endurance test report for engine as per is :10001 latest/ls:10002 latest,type test report for alternator as per is : 13364 (part-1) latest/is: 13364 (part-2) latest to prove conformity to the specification , make-cummins power, greaves, kirloskar or similar [ warranty period: 30 months after the date of delivery ] ]
Tender For 125 kva diesel generator set with amf control panel, power generator installation configuration as defined in cpwd general specifications for electrical works-part-vii (dg set) -fixed (power generators are permanently installed), nominal rated capacity (kva)-125, rated engine power(kwa)- 110% of the required powered at stp (standard temperature pressure) i.e equal ? to (nominal rated capacity (kva) of power generator any auxiliary power consumption by the power generator) x power factor (0.8)/alternator efficiency , type of governor-electronic, rated rpm of engine(rpm)-1500, fuel-high speed diesel (hsd),control panel-amf control panel , installation- with installation-inclusive in the scope of supply, warranty on complete power generator/dg set-24 months , no . of phase- 3, number of cylinders-6,starting voltage-24, type of alternator-brushless, fuel tank capacity- 275 liter, battery capacity(ah)-100,no. of battery- 2, testing report available for(test/approval)-type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb,cop certificate for engine type test report and endurance test report for engine as per is :10001 latest/ls:10002 latest,type test report for alternator as per is : 13364 (part-1) latest/is: 13364 (part-2) latest to prove conformity to the specification , make-cummins power, greaves, kirloskar or similar [ warranty period: 30 months after the date of delivery ] ]