Get complete information related to latest Waterproofing Works Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Waterproofing Works Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Waterproofing Works Tenders.
Tender For corrigendum : annual rate contract for conservation, restoration,reconstruction & redevelopment works (surfacecleaning, site clearance, brick masonary, stonemasonary, lime concrete, lime mortar, structuralstrengthening, dismantling & demolishing, flooring,roofing, finishing, wood works repairs and waterproofingworks and other miscellaneous works)at office of the assistant director of archaeology,northern circle (ahmedabad) of department ofarchaeology, gujarat.
Tender For corrigendum : annual rate contract for conservation, restoration,reconstruction & redevelopment works (surfacecleaning, site clearance, brick masonary, stonemasonary, lime concrete, lime mortar, structuralstrengthening, dismantling & demolishing, flooring,roofing, finishing, wood works repairs and waterproofingworks and other miscellaneous works)at office of the superintending archaeologist, kutchcircle of department of archaeology, gujarat.
Tender For corrigendum : annual rate contract for conservation, restoration,reconstruction & redevelopment works (surfacecleaning, site clearance, brick masonary, stonemasonary, lime concrete, lime mortar, structuralstrengthening, dismantling & demolishing, flooring,roofing, finishing, wood works repairs and waterproofingworks and other miscellaneous works)at office of the assistant director of archaeology,western circle (rajkot) of department ofarchaeology, gujarat.
Tender For corrigendum : supply of providing and laying of painting works , patch works , waterproofingworks , dismantling false ceiling , dismantling bison board , dismantling woden partistion , window closing , dismantling existing washbasin , cleaning , room 3 , providing toilets , toilet renovation works , roofing and false celing works , room 9 , floor patch works , dismantling of toilets , dismantling damaged windows , room 14 15 , dismantling existing doors , repairs to existing ventilator windows , dismantling existing wall and floor tiles , structural repair and opening modification works , dismantling brick structure and floor repair , dismantling and vegetation removal , dismantling existing broken and damaged glass panes , cpvc water supply line , site clearance and general demolition works , anti termite treatment , rodent and pest control treatment , overhead water tank cleaning repair and disinfection , storm water drain and surface drainage , signage and room identification , comprehensive checking of 1 nos 250 kva outdoor type substations including inspection , aluminium paint , servicing of existing 11 kv 400 amps 3 pole gang operated type air break ab switch , supplying and replacing damaged or worn out copper metal , supplying and replacing damaged or defective 11 kv post top insulators , supplying and replacing damaged or defective 11 kv pin type insulators , servicing of earth pits , supply installation testing and commissioning lbs , xlpe insulated aluminium conductor armoured ht cable , providing indoor or outdoor type heat shrinkable , supplying and laying of 3.5 core x 240 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , supplying and making end termination for 3.5 core x 240 sq.mm 1.1 kv grade , joint for existing single run lt power cable of size 3.5 core x 240 sq.mm , comprehensive servicing and preventive maintenance of existing ht transformer , supply, fixing, installation, testing and commissioning of lightning arrester , providing and fixing cable identification tags , supply, installation, testing and commissioning sitc main mv panel , supply, installation, testing and commissioning sitc cubicle pdb panel , supply, installation, testing and commissioning sitc feeder pillar box , providing and installation of maintenance free earthing station , supplying and laying of 3.5 core x 120 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , providing laying and fixing of overhead perforated or slotted ms cable tray , supply installation testing and commissioning 7 segment distribution board , providing fabricating supplying, installing testing and commissioning of electrical socket box
Tender For providing of building materials and execution of the allied works under the work conservation of well area of lahore gate including rampart at red fort - material and work, u. lime katni (in air tight bags), surkhi (free from silt, dust, organic any other foreign material), river course sand (free from silt, dust, organic any other foreign material), gum babool, gur desi, belgiri, jute/sun, lakhori brick (as per site requirements nominal size & specification), brick jeera 6mm (free from clay, organic material), brick aggregate (free from clay, organic material) 20 to 25 mm nominal size, red sand stone thickness 100mm of required size, copper dowel (as per site requirement), red sand stone required (as per site requirement size), red sand stone 50 mm (as per site required size thick for jalie work), red sand stone 40 mm (as per site required size thick undressed for chajja), copper rod 10 mm (as per site requirement), un slaked lime katni (in air tight bags) fine quality, marble dust powder [kg], batasha [kg], araldite [kg], 6 inch dia ballies (6 ft ) [each], ply 12mm thick [m2] water resistant, mud (clay ) [cum] free from impurities, dry uppley [each], planks 50m thick [m2] (well seasoned), jute rope 1 inch [kg], "dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres leaddismantling old lime plaster", demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge.nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix), demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge., painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture, provision of provising and fixing of galvanised mild steel material xpended material (xpm) jali of 4mm thick silver in clour inluding fixing charges etc complete, "float glass panes 9.7.7.1 4 mm thick glass pane (weight not less than 10kg/sqm)", "providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.2 sal wood", "providing and fixing factory made single extruded wpc (wood polymer composite) solid plain flush door shutter of required size comprising of virgin polymer of k value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 n (face) & 900 n (edge), minimum compressive strength 50 n/mm2, modulus of elasticity 850 n/mm2 and resistance to spread of flame of class a category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk s.s screws, all as per direction of engineer-in- charge. (note: stainless steel butt hinges and necessary s.s screws shall be paid separately) 30 mm thick 26.87.1", "providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the rcc structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry :
Tender For providing and laying app water proofing treatment over roofs and resipolyproof treatment walls of building no.6, 7 and other miscellaneous waterproofingworks at custom colony, five garden.subwork/packages:providing and laying app water proofing treatment over roofs and resi polyproof treatment walls of building no.6, 7 and other miscellaneous water proofing works at custom colony, five garden.
Tender For corrigendum : provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate nu
Tender For fire work at esic haryana. - (a) supplying, installation, testing and commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required :(b) horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp squirrel cage induction motor, tefc, synchronous speed 1500 rpm, suitable for operation on 415 volts, 3 phase 50 hz, ac supply with ip 55 protection for enclosure, horizontal foot mounted typewith class-f insulation, conforming to is-325.(d) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plasteredwith anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required:(diesel driven pump)(b) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulatedwith 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event offault with audio indications, painted with post office red colour etc. as required.(d) m.s fabricated, common base plate, coupling, couplingguard, foundation bolts etc. as required.(e)suitable cement concrete foundation duly plasteredand with anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (jockey pump)(b)horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is : 1520.(c) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase 50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class-f insulation, conforming to is : 325.(d) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plastered and with anti vibration pads., 180 lpm @70m head, fabrication, supply, insallation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :, incomings630a, 50ka 4 pole mccb, ics=100% icu rating digital voltmeter 0-500v with selector switch ammeter (0-630 a) with selector swtich & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps set of copper bus bar 800amps outgoings (note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump200 amp, 50ka tpn mccb, ics=100% icu, with f