Tender For providing of repair and overhauling service - dimensioning and weighing systems (volumetric weighingmachine); repair of digital weighingmachine; yes; buyer premises
Tender For supply of laboratory items for govt college, jayal, nagaur-341023 - chemistry, hot air oven triple walled in construction with inner made of stainless steel & exterior of steel with powder coat finish. food grade silicon rubber gasket which acts as a perfect sealant. high density compressed 100 mm glass wool insulation between the walls to prevent heat dissipation. a fully insulated rigid door fitted with heavy duty hinges and ball catch locking system. temperature controlled by dual led display microprocessor based temperature controller & pt 100 sensors. heating elements are made of high grade nichrome wire and provided on the side walls of the chamber. air circulation by motorized blower placed on top of the oven. exhaust/ventilation provided on either sides. left & right sides of the inner chamber are duly perforated for proper air circulation & to maintain uniform temperature within the chamber. available with removable ss rod shelves 3 nos. temperature range: 5 c above ambient to 250 c. temperature accuracy: 0.5 c or better. working space 18 x 18 x 18 inch or capacity 95 liter. operates on 230 volts ac single phase 50 hz. safety feature: capillary type thermostat provided to take care of temperature overshoots, working space (wxdxh)inch: 14x14x14 capacity: 45 ltrs. watts: 1500 shelves: 2 nos., digital melting point apparatusmelting point apparatus with 4 digit, 7-segment led display is designed for accurate measurement of melting points and for checking the melting range of the solid samples. the apparatus consists of a silicon bath of about 200 ml capacity, covered with teflon cover with 3 holes fitted, with a special type of oil immersion heater having three holes for holding the capillaries, one for boiling point tube and one for the thermometer. the apparatus consists of in-built magnetic stirrer, an electronic controller with indicator for precisely adjusting the rate of heating of silicon oil-bath, an on/off switch, a pilot lamp, with magnifier, a glare free background illuminator, a high/low range temperature selector switch and digital temperature indicator with sensor extremely useful for pharmaceutical industry 4 digit 7-segment led display display 4 digit, 7-segment led display temperature 0 300 c resolution 0.1 c, sample amount fine powder properly dried at a temperature considerably below its melting point 4 6 mm high oil-bath silicon oil-bath beaker 200 ml capacity with teflon cover fitted with oil immersion heater. it has three holes for holding the capillaries, boiling point tube and thermometer stirrer speed controllable with front knob power 230 v 10%, 50 hz. ac dimensions 315 x 290 x 290 mm (l x b x h), analytical balanceinternal calibration (weigh sensor) to match the highest international standards. internal calibration fully automatic motorized internal built in weights calibration. perfect self auto calibration (psac) when the ambient temperature changes by a specific value or once a defined time interval has elapsed, it performs internal calibration. overload protection capacity tracker built into display for easily monitoring possible overloads. excellent readability high-contrast, backlit display 15mm digits size is exceptionally easy to read under any room lighting conditions. below weighing hook hook for weighing below the balance. automatic shut off for power saving mode, maximum capacity 220 gm minimum load 10mg readability 0.1 mg repeatability (sd) 0.1 mg linearity ( ) 0.2 mg, tare range (subtractive) 220 gm usp minimum weight 160 mg pan size (mm) 90 response time 2 - 3 sec. display alpha numeric backlite lcd display calibration motorised internal calibration units of measure gm, mg, ct, gn, mo, oz, dwt, t1t, t1h, t1s, mom, bat, ms operating temp. 18 to 30 c sensitivity drift. 2ppm (2 x 10 / c) -6 optional usb (windows direct communication). application modes pcs, % weighing, animal / dynamic weighing, check weighing, automatic density determination, formulation automatic st
Tender For medical equipment and other equipments repairs and paint in hospitals in shimoga district - basen stand for repair , horizontal auto clave repair, refrigerator, pharmacy rack repair, stoll steel/iron paint , stoll steel/iron repair, table fan repair, ceiling fan repair, head light ent, fumigator repair, stoll steel/iron repair , digital weighingmachinerepair, manual b p appratus repair, oxygen cylinders repair, ecg machinerepair, nebuliser repair, manual sucker repair, electrical sucker repair, silent generator repair, drip stand for paint, oxygen concentrator repair, faging machine for repair, baby warmer repair, fetal doppler, electrical suction operator repair, operation table hydraulic for repair, drip stand for repair, operation theatre lamp for repair, autoclave for repair (small), autoclave for repair (big), emergency o.t. light for repair, revolving stool for repair, three seaters visitors chairs for paint, three seaters visitors chairs for repair, wooden chair for polish, wooden chair for repair, structure trolly for paint, wooden/ steel bench for polish, wooden/ steel bench for repair, folding chairs for paint, folding chairs for repair, wooden almirah big and small polish, dust bin stand for paint, structure trolly for repair (small), dust bin stand for repair, office steel chair for paint, office steel chair for repair, bed side locker for paint, bed side locker for repair, oxygen cylinder stand for paint, oxygen cylinder stand for repair, basen stand for paint , structure trolly for repair (big)
Tender For rate contract for the procurement of consumables/non-consumables for the department of physiology - battery rechargeable 3000mah - aa 1.5v, battery rechargeable 900mah- aaa 1.5v, blotting paper - regular (filter paper) 60 x 60 cm, clamp electrodes for mortara eli 250 - one set should consist of 4 colors - black, red, yellow and green, corrugated tube antistatic :105 cm x 22 mm ( spares for student‘s spirometer), crocodile clip with plastic shield, ecg patient cable for mortara eli 250 - one piece cable with non replaceable banana end connectors and 15 pin d- sub connector, heparinized capillary tubes (100mm length, 0.5mm internal diameter) - pack size - 100 nos/pack, ishihara chart book for testing colour blindness with interpretation, jager‘s chart for near vision, "kymograph drum paper -measurements: length - 21 inches or more, width - 6 inches", lancets (sterile disposable) (pack of 200 nos), "micro capillary tube for clotting time 15cm in length& 0.1 mm in diameter without anti-coagulant - pack size - 100 nos/pack", microscopic oil (pack of 500 ml), mouthpiece disposable for vitellometer samples neded, near vision test type book sample needed, neubauer chamber with improved neubauer ruling (sample should be provided, if not will be subjected to rejection), pen torch light (runs with 2 aa batteries), perimetry charts, plastic dropper (diameter - 3 mm, total length - 8 cm, tube length - 6 cm), plastic tailor's measuring tape - 60 inches or 152 cms, power cord for monocular microscopes, pre gel electrods, "rbc pipette (german make)make: rohem'/riviera'/bioplus'/sunbeem (sample to be submitted, if not will be subjected to rejection)", sahli's heamoglobin pipette, sahli's heamoglobin stirrer, sahli's heamoglobin tube, silicon tubing - inner diameter - 10 mm, outer diameter - 6 mm for use in sthethography, snellen‘s chart for visual acuity with english alphabets, tissue paper roll - 100grm, wbc pipette (german make) make: rohem'/riviera'/bioplus'/sunbeem (sample to be submitted, if not will be subjected to rejection), whatman filter paper no. 1- pack size - 100 nos/pack, equipments / small instruments, "adjustable height scale (wall mountable: 30-200 cm, resolution: 0.1 cm, graduations in mm) (sample to be demonstrated. otherwise subject to rejection).warranty 1 year", "algometer1. cylindrical metal body with one end consisting of a sliding metal slab with graduations marked 0, 1, 2, 3, 4 kgs2. one end is hand held and other is pressed on the body3. sample to be demonstrated", aneroid sphygmomanometer, artery forceps 5 â½" curved, artery forceps 5 â½" straight, "automated blood pressure monitor with arm cuffs of 3 sizes:1. upper arm cuff - i) pediatric sizeii) adult sizeiii) extralarge adult sizeto be validated by world hypertension league.warranty 1 year", "centrifuge apparatus:1. maximum rotational speed: 6000 rpm or above,2. maximum relative centrifugal force: 5070 g or above,3. angle head'/swing out heads for holding test tubes4. max capacity: 24 x 15 ml, safety lid interlock to prevent coveropening during centrifuge. warranty 2 years", "centrifuge• digital speed indicator• number of slots 8• rotator capacity 8x15ml• speed 5000rpm• warranty 1 year• step less speed regulator.• safety lid interlock during centrifugation.• digital speed meter and digital countdown timer. (sample to be demonstrated). warranty 1 year", "compass aesthesiometer-1. metal body with length 8 – 12 cm2. two arms with adjustable screw to increase or decrease the distance between the two tips from 0 to 7cm.3. sample to be demonstrated.", "detachable ink writing apparatus with ink well for writing on kymograph paper (to be used with marey's tambour for stethography):1. writing ink – blue (4 nos)2. writing to be demonstrated.", digital chemical weighing balance scale ( 0.01gm- 500 gms) with wind shield and spatula. warranty 1 year, digital weighing scale ( measuring max weight of 180 kg), "ecg machine (brand: rms / bpl )1. sing
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer- the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks.warranty must be one year., electronic balance- the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. warranty must be one year., vaccum pump - the pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted withvacuum and filter cartridge., hot air oven- the inner chamber should be made of stainlesssteel and the outer chamber should be m.s powdercoated. the maximum capacity of the oven shouldbe 100 ml or more. the operational temperatureshould be between ambient to 250oc or more witha temperature accuracy of 1o c. pid based digitaltemperature control., double distillation unit- the unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil bath- the oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240oc (0.1oc increment) with a temperature stability of 1oc, water bath- the water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars., ph/ condutivity meter - operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range shouldbe in between 0.00 to 29.99 s/cm, uv cabinet- operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometer- application: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca 2+ :0-99.9 ppmli 2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required
Tender For supply of equipment and instruments under support for diagnostic infrastructure under 15th fc - items, hemoglobinometer electronic, semi automated bio chemistry analyzer, supply of reagents for semi auto bio chemistry analyzer considering 6 tests per day for 6 months for 1 units, fully automated bio chemistry analyzer, supply of reagents for fully auto bio chemistry analyzer considering 6 tests per day for 6 months for 1 units, 3-part hematology analyser, supply of reagents for 3- part hematology analyser considering 6 tests per day for 6 months for 1 units, spirometer, rotor/shaker, esr analyser, supply of reagents for esr analyser considering 6 tests per day for 6 months for 1 unit, turbidometer/nephelometer, autoclave vertical - 100 lts, steriliser drum medium, nebuliser - adult, tuning fork 512 hz, handheld xray, incubator, hot air oven, ishihara chart, urine strip analyzer, digital weighingmachine adult, cetrifuge 6 tubes, oxygen hood mask for infants, laryngoscope with all accessories, hub cutter, otoscope led, ecg machine-digital with all accessories, mucus extractor, bp instrument , digital with charger, refrigerator thermometer, room thermometer, steriliser drum small, screen 4 fold, foot operated dustbin for bmw colour coded set, iv stand, almirah large, bed side table, mattress, pillow, blankets, mosquito nets, bar code with printer, 3 kva ups with battery for lab, auto clave 23 ltrs, nebulizer - pediatric, foot operated dustbin for bmw colour coded set, nasal prongs, nasal specullum, mouth mirror, needle holder, ear specullum, tongue depressor, cheatles forceps, toothed forceps, artery forcep, snellen chart, near vision chart, dental explorer, alligator forcep/foreign body removal forcep, led head lamp, sponge holding forcep, oxygen flow meter set, scissors straight, umbilical cord scissors/ cord cutting scissors, digital thermometer, tileys nasal dressing forcep, sethoscope, foetoscope, test tube stand 8-10 tubes, test tube 5 ml borosil, examination lamp with stand, dressing drums medium, kidney tray medium, sims retractor, digital scope, stadiometer, adult weighing scale digital, infant weighing scale digital, radiant warmer, peak flow meter, centrifuge 4 tubes, centrifuge tubes 5 ml, dental chair with x-ray, pendodontic forceps (upper), pendodontic forceps (lower), spoon excavator, mouth mirror, probe & explorer, tweezers, cow horn forceps upper (right and left), cow horn forceps lower (right and left), root forceps, apex elevator 4mm, warwick james elevator, coupland, contra-angle handpeice, uv chamber, ballburnisher, b class autoclave, scaler tips (6/7), sutures & needles, laptop for rvg x-ray, balance paraled bar for addult, balance paralle bar for peaditrics, physiotherapy beds, tens machine, ift machine, ultrasound machine, laser machine, shoulder wheel exercise machine, padeitrics floor carpet, continuous passive movement machine upper limb, continuous passive movement machine lower limb, 1 kva ups with battery, 5 kva ups with battery, earthing and minor electrical connection works required for installation of machines/ equipments at phcs, shcs & uphcs (payment will be done as per actual)