Tender For tender for supply of soil lab instruments d d - rolling thin film oven , cone drop test apparatus for geosynthetic , soil electrical resistivity meter , electromagnetic sieve shaker for soil , abrasion resistance testing machine for geotextile
Tender For procurement of testingequipment for all power houses at thc sirmour - digital insulation testers (megger)range: 0-100/250/500/1000v, digital insulation testers (megger)range: 0-100/250/500/5000v, digital multimeterfeatures:dc & ac voltage; ac & dc current; continuity & resistance ; capacitance and inductance; checking of diodes/ transistors, single phase variable voltage autotransformers: details of single phase auto transformer 15a rating -input: 220v ac 10%; output: 0 to 270 volts.rating: 15 amps, three phase variable voltage autotransformers: details of three phase auto transformer 15a rating -input: 415v ac 10%; output: 0 to 500 volts, 3 phases.rating: 15 amps., tong tester cum multi meter (digital) (clamp on meter for ac measurements) specification for 0-1000a ac digital tong tester (clamp on meter) - current range: 0 to 1000 a (with settings of 1/10/20/40/100 a/500a/1000a auto ranging); voltage range: 0 to 60/300/600 v ac; accuracy: 0.3% or better, tong tester cum multi meter (digital) (clamp on meter for dc measurements) specification for 0-300a dc digital tong tester (clamp on meter) - current range: 0 to 300a (with settings of 1/10/20/50/100 a/300a auto ranging) ; voltage range: 0 to 60/120/300 v dc.accuracy: 0.3% or better., tong tester cum multi meter (digital) (clamp on meter for ac/dc measurements) specification for 0-100a ac digital tong tester (clamp on meter) - current range: 0 to 100 a (with settings of 00-20ma/100ma/500ma/1a/10a/50a/100a auto ranging); voltage range: 0 to 60/300/600 v ac; accuracy: 0.3% or better, digital phase sequence indicator: dial size: 96x96mm (minimum) ; working voltage: 50 to 500v ac; frequency: 25 to 60 cycles., digital earth resistance clamp meter with leakage current measurement
Tender For corrigendum : supply, installation and commissioning of machinery / testingequipment/apparatus to establish workshop in jdvvnl’s premises for repair of failed distribution transformers
Tender For corrigendum : supply installation and commissioning of machinery testingequipment_apparatus to establish workshop in jdvvnls premises for repair of failed distribution transformers - supply, installation and commissioning of machinery / testingequipment/apparatus to establish workshop in jdvvnl s premises for repair of failed distribution transformers against tn-2067, cost of annual maintenance charges to charged annuallly for next five (5) years after expiry of guarantee period
Tender For tender for supply of lab eqipment d d - cbr value digital automatic cbr testing machine with accessaries as per is 2720 part 16 , marshal stability automatic analogue marshal stability apparatus 100 kn for 4 inch and 6 inch , moisture content of material infrared moisture meter , digital thermometer minus 50 degree celsius to 280 degree celsius , digital screw gauge , 50 kg capacity electronic balance type accuracy 2 gm , digital electronic balance 5 kg capacity 0 point 50 gm accuracy specification as per uploadedpdf document , laboratory concrete mixer consists of a steel vessel of 30 litres mounted on a frame specification as per uploaded pdf document , vibrating table vibrating tables of table top size 100cm x 100cm plus or mius 10mm specification as per uploaded pdf document , aggregate impact tester , crushing value apparatus , sample tray gi , slump test apparatus , loss angeles abrasion testiing machine with counter , sieve shaker motorised for 20 cm dia sieve with built in digital timer , digital compression testing machine capacity 3000kn conform to is14858 specification as per uploaded pdf document 2000 and calibrated with an accuracy of plus or minus 1% as per the requirement of 1828 class1 capacity 3000kn resolution point 1kn clearance between upper and lower platens maximum 400mm distance between side plates maximum 400mm platen dia min272.0 mm dia remaining specification as per uploaded pdf document , standard test sieves gi frame a set of 26 different size , standard test sieves brass a set of 35 differencet size , ennore standard sand 50 kgs bag , specific gravity apparatus , speedy moisture meter , bitumen extrator motorized with vaualble speed with digital rpm inidicator , chemical balance 100 gm capacity accuracy 0 point 001 gm , stop watch 1 by 5 sec accuracy , measuring cylinder 100 ml make borosilicate glass , measuring cylinder 500 ml make borosilicate glass , measuring cylinder 1000 ml make borosilicate glass , rain guage automatic recording type with chartconforming to is 5235 , flakiness index thickness gauge is 2386 , digital thermometer power source battery specifiction as per uploaded pdf document , cube mould 150 mm made of cast iron specification as per uploaded pdf documents , cube mould 70 point 6mm made of cast iron specification as per uploaded pdf document , le chatelier apparatus for soundness complete set onforming to is 6932 part x , engine core cutting machine , stanone stmh1 type n rebound concrete test hammer , curing tank specification as per uploaded pdf document , sand pouring cylinder apparatus ref standard is2720 part 28 ref standard is 2720 part 28
Tender For supply of lab eqpts d d--atm universal testing machine (q3) , motorized core cutting machine (q3) , infrared moisture meter , core cutter apparatus , auger outlift post hole type with 50mm dia auger head , auger outlift post hole type with 100mm dia auger head , electronic balance 20kg, 1gm readability , electronic balance 600gm, 0 point 01gm readability , thickness gauge , benzene , hos ennore sand grade1 , hos ennore sand grade2 , hos ennore sand grade3 , marshal test apparatus with digital display , centrifuge extractor motorised , liquid limit test apparatus manual , shrinkage limit test equipment , plate bearing test apparatus , apparatus for determination of specific gravity of fine and coarse aggregate , pan concrete mixture , vibrating table , rebar locator and corrosion analyser , benkelman beam apparatus , bitumen viscosity test apparatus , maximum theoretical specific gravity test apparatus , cement mortar cube vibrating machine , rain guage ) /bid number : gem/2025/b/6865330 * /dated: 07-11-2025 & & / bid document 1 / 30
Tender For supply of various lab equipments items for govt. pg college guna district guna (m.p.) 2nd call - supply of various lab equipments items for govt. p g college guna district guna (m.p.), waterand soil testing analysis kit (digital) : range ph 0 to 14.00 resolution ph 0.01 accuracy ph 0.01 1 digit temp. comp. 0 to 100 deg. c., water bath (06holes) : 6 hole8 ltrs., waterbath(12holes) :12 hole 20 ltrs., water distillation apparatus(single distillation unit 2 litre/hour) : single distillation 5 litres, analytical balance : least cosunt 0.0002g, analytical weight box : 1-100g, fractional weight box : 1-500mg, physical balance : 250gm accuracy 0.1g, digital balance : least count 1mg, single pandigital balance : 0.1mg 200g, digital photoelectric colorimeter : 8 filter,1 ml, digital potentiometer : with hot plate and electrodes, digital conductometer : with cell 1cc and 0.1cc, d.o. meter : polarographic do range: typically 0 to 90 mg/l (milligrams per liter) or 0 to 600% saturation.rdo (optical) do range: usually 0 to 50 mg/l or 0 to 500% saturation., digital naphelo/turbidity meter : digital turbidity cum nephelometer range:-, 200,1000 ntu/jtu resolution:- 0.01 ntu/jtu accuracy:- 3% fs, 1digit display:- 3 digit 7-segment led light source:- ir led detector:- photodiode sample system:- 60 x 25mm clear glass test tubes power:- 230 v 10% ac, 50 hz accessories:- test tube set of 2, operation manual, dust cover, polarimeter half shade : the specific rotation ( ) is a physical property defined as the optical rotation at a path length of 1 dm, a concentration of 10 g/l, a temperature (usually 20 c), and a light wavelength (usually sodium d line at 589.3 nm), melting point apparatus :melting-point measurement range: room temperature - 400 c setting rate of the starting temp. : 50 c~400 c 5 min; 400 c~50 c 7 min minimum digital display: 0.1 c size of the capillary: 1.4mm (outside diameter) 1.0mm (inside diameter), 90mm equipped with color camera and color monitor to observe melting point with ease validation program for standard samples 8 operator names can be storedgraphic lcd display to display all test parameters & test instructions, digital melting point apparatus :melting point measurement range : ambient to 300 deg c starting melting point temperature : settable from 50 to 300 deg c heating time : 3 minutes (up to 300deg c) cooling time : 5 minutes (from 300 deg c) accuracy : +/ 0.5 deg up to 200 +/ 0.8 deg from 200 to 300 temperature display resolution : 0.1 deg c rate of heating (deg c per minute), abbe refractometer : safety bs en 60950-1:11/2006 emc en 55024 : 10/2003 en 55020 : 11/2005, tlc kit : outstanding standardization and quality control exceptional adherence, hardness and surface homogeneity. analyzing samples with high matrix- load without sample preparation. multiple samples analyzed in parallel.highly cost-efficient, fast and economical, centrifuge : 6000rpm, corkboring machine :adjustable guide that permits holes to be bored in any part of a stopper, the knurled chuck - 9/16" (14mm) shank of the eight, plated-steel borers included with the unit. the steel borers range from 3/16" to 5/8" (4.8mm to 15.9mm) in 1/16" (1.6mm) increments,, distillation apparatus : single distillation 5 litres, oven hot air : 14" 14" 14 , voltage stabilizer : 2kv, vertex shaker : 6 tube capacity, mixer small : moter capacity 900 watt, water bath(cu) : 4 , heating mantle with energy regulator : 500 w,2litre, single crucible heater : helical wire coil moldatherm insulation platinel ii thermocouple with 10tm compensated lead wire and polarized plug ceramic fiber hearthplate programmable heat-up to setpoint temperature indicates setpoint and process temperatures temperature: 1200 c (2192 f) maximum crucible sizes: 5 (top vestibule id) x 8 (heated depth), water bath rectangularsingle walled : 6 hole 8 ltrs., water bath rectangular :2 hole, kjeldahl distillation unit : unit of 3 tests, microwave oven : 30 ltr convection compatible, soleextractionuni