Get complete information related to latest Wire Bundle Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wire Bundle Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wire Bundle Tenders.
Tender For corrigendum : supply of 415v, utilization category ac23a, 630a local isolator cabinet in sheet steel enclosure complete with 630a, 3 pole load break switch. 2. shall be with side operated handle, padlocking facility, prebreak micro switch having 1no+1nc contact. 3. micro switch contacts shall be wired to 4 sq mm tb for external termination. 4. provision of padlock system having sufficient space to lock the isolator at off position by minimum two agencies at a time. 5. complete with both power & control circuit wiring with all insulators, bus bars and control terminal blocks. 6. detachable bottom gland plate for entry of cables from bottom. 7. front door shall be hinged and inter-locked with the isolator in 'on' position. the front door should have a minimum 3 mm thickness perspex/triplex window for observation of position of contacts. 8. isolator should confirm to iec 60364 standard. 9. the dimensional drawing of the local isolator cabinet or product catalogue showing mounting arrangement of the components should be enclosed along with the offer. 10. isolator cabinet should be provided with rain canopy. 11. any isolator parts should not be made of aluminium/aluminium alloy. 12. isolator cabinet shall be metal enclosed suitable for wall fixing using 4 welded fixations, dust and vermin proof and shall be provided with degree of protection as ip-55. 13. provision for three distinct parallel busbar per phase for termination of three nos of 240 sqmm aluminum cables for incoming and two distinct busbar per phase for termination of 120 sqmm copper cable. 14. all hardware used in isolator cabinet shall be corrosion resistant. 15. minimum clearance between the live parts and detachable bottom cable gland plate shall be 400mm. 16. cabinet should be painted with alkaline resistant epoxy paint. 17. isolator cabinet shall have provision for earthing at two separate and distinct points. 18. each isolator cabinet should be supplied with panel keys., push button station specification: 1. pbs made of 2mm sheet steel enclosure with rain canopy, protection: ip-65. 2. 01 no. of green colour start pb with 1no+1nc contacts, 01 no. of red colour stop pb with 1no+1nc contacts, 01 no.of increase pb with 1no+1nc contacts <(>&<)> 01 no.of decrease pb with 1no+1nc contacts. one emergency stop push button with 1no+1nc contacts (push to lock type) shall be provided. size of each push button is of 22.5mm diameter. inscription plate for all push buttons. 3. pb shall be wired with 2.5 sq.mm. copper wire to 40 nos. serially numbered terminal blocks (tb) of elmex make having tb-5-6, 7-8, 11-12, 13-14 <(>&<)> 17-18 shorting link. 4. two nos. of cut out of size 72x72 mm for ammeter and rpm meter shall be provided. 5. 'on','off' <(>&<)> 'trip' indication led lamps in red, green <(>&<)> amber colour respectively with inscription plate to be provided. 6. all push buttons, elements, led lamps <(>&<)> cutout for ammeter <(>&<)> rpm meter shall be on the hinged door of the pb station. 7. pb station shall be weather proof, neoprene rubber gasket suitable for outdoor application. 8. 2nos. of earthing studs to be provided. 9. left side hinged door shall be provided with flexible braided copper earthing. 10. pbs shall have 04 nos. of corrosion free bracket suitable to fix on vertical surface. 11. detachable gland plate to be provided. 12. the push button shall be painted with one coat of red oxide primer <(>&<)> two coats of zinc chromate primer and finally finished with stoving enamel grey paint. 13. the push button station shall be generally in line of enclosed drawing (fig-2). 14. party to submit the drawing along with the offer for technical scrutiny.
Tender For bid to ras corrigendum : supply of hydraulic hoses and end fittings applicable to hemm models - hose wire braided r4 fire or heat resistance 0.5 inch 6000 psi , hose wire braided r4 fire or heat resistance 1.25 inch 6000 psi , hose wire braided r4 fire or heat resistance 1.5 inch 6000 psi , hose wire braided r4 fire or heat resistance 2 inch 6000 psi , socket for crimping hose r4 id 0.5 inch with end fitting , socket for crimping hose r4 id 0.625 inch with end fitting , socket for crimping hose r4 id 0.75 inch with end fitting , socket for crimping hose r4 id 1 inch with end fitting , socket for crimping hose r4 id 1.25 inch with end fitting , socket for crimping hose r4 id 1.5 inch with end fitting , socket for crimping hose r4 id 2 inch with end fitting , hose wire braided r2 fire or heat resistance 0.5 inch 3000 psi , hose wire braided r2 fire or heat resistance 1.25 inch 3000 psi , hose wire braided r2 fire or heat resistance 1.5 inch 3000 psi , hose wire braided r2 fire or heat resistance 2 inch 3000 psi , socket for crimping hose r2 id 0.5 inch with end fitting , socket for crimping hose r2 id 0.625 inch with end fitting , socket for crimping hose r2 id 0.75 inch with end fitting , socket for crimping hose r2 id1 inch with end fitting , socket for crimping hose r2 id 1.25 inch with end fitting , socket for crimping hose r2 id 1.5 inch with end fitting , socket for crimping hose r2 id 2 inch with end fitting
Tender For tender for supply of attending ea set located upto 25km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 25km to 50km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 50km to 100km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 100km to 200km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , carry out b check servicing of 7.5kva to 15kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 15kva to 32.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 32.5kva to 62.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool n tackle etc as reqd , carry out b check servicing of above 62.5kva to 125kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 160 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 200 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 250 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , providing and fixing of 12mm dia wire braided pvc pipe for diesel supply and return lines in existing ea set incl. testing , commissioning etc as reqd , providing and fixing of benjo and benjo bolt with washer and scew on pipe clamps at both ends for existing ea set incl. testing , commissioning etc as reqd , providing and topping up of corrosion inhibitor coolant in radiator of existing ea set incl. testing , commissioning etc. as reqd. , providing and topping up of 15w40 grade lubricating oil of recommended make in existing ea set incl. testing , commissioning etc. as reqd. , providing and fixing of 2 no. 50 sqmm copper conductor flexible cable leads each of 1 mtr length incl. lugs and battery terminals at both ends for starting battery of existing ea set as reqd. , providing and fixing of battery terminal socket set for dg starting battery incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve suitable for 7.5 kva to 32.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve with solenoid switch suitable for 45 kva to 125 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 7.5 kva to 62.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 75 kva to 250 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of ignition switch or push button for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of engine start key switch incl. testing , commissioning etc. as reqd. , providing and fixing of oil pressure guage for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of water temperature guage for ea set incl. testin