Web Analytics Made Easy - StatCounter

Workshop Building Repair Tenders

Get complete information related to latest Workshop Building Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Workshop Building Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Workshop Building Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :38825986 Due date: 25 Feb, 202525 Feb, 2025 1.57 Crore
Tender For corrigendum : construction, testing and commissioning of steel fabricated structure 15 nos. of 10 kl capacity staging 9 mtr. including construction of suitable r.c.c. valve chamber in village . providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia hdpe class 10 kg/sqcm of 1350 mtr. valve specials and all fittings including all allied civil works, supplying & installation of energy efficiant five star bee rating isi marked required capacity three/single phase, 50 hz, 415v, deep well submersible pump stainless steel body, suitable for 4"/6" tube well with control panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc 15 nos. as required as per specifications but excluding pipe, ss/nylonwire rope and connection cable including verification of tube well yield. & electric connection from cseb, construction of brick masonry switch room of size 1.50*1.50*3.00 mtr (15 nos), providing 0 no functional household tap connection (f.h.t.c) (pe-al-pe pipe 0 mtr) in individual households and government instiution etc.drilling of 150 mm dia 130 m deep ordinary tube well 15 nos. complete with trial run operation & maintanance for 03 months under single village piped water supply scheme under jal jeevan mission for village bhadu, bahora, marangi, samarbar, sanna & gurmhakona in block bagicha district jashpur.

CTN :38904079 Due date: 31 Jan, 202531 Jan, 2025 NA
Tender For supply of watch tower , sitc of prefab security post of size 10x12x10ft with control panel and including wpn storage safe for pers wpn , sitc of all-weather proof 24x7 operated vehicle inspection area of size 50 x 50 x25ft having infra red cameras for capturing number plate and video recording of inspection procedure. , sitc of boom barrier self operated remote controlled with span up to 25 ft , sitc of motorised ms gate heavy duty of size 29 ft x 14 ft , full height turnstile single lane , sitc of spike busters 50 tons approved capacity , day and night ptz camera vision sensor base motion detection camera with 180 tilt and span and 50 meter hd zoom alongwith nvr and cables amplifiers, and supporting software , anprc night and day hd camera with software connected through data cable trenches in m20 grade to conceal them ug with ik 10 test load casing , two way camera with storage having 180 degree tilt and span with zoom , visitor management system with software and work station , application supporting software for security related equipment , infra structure for control room , cabling conduits, boosters, amplifier, ups and other security related accessories each , sitc of fire fighting water storage 70 percentage bff and 30 percentage aff for fire fighting with high pressure water gun , plc based controlled ip 65 fixture with range of 200 meters , allied civil work and electric works for installation of security related equipment bid number/ & ( * ) : gem/2025/b/5780778 dated/ + : 10-01-2025 bid document/ 2 2 1 / 20

Central Government/Public Sector

CTN :39010829 Due date: 04 Feb, 202504 Feb, 2025 42.53 Lacs
Tender For tender for supply of operation and daily basis maintenance/servicing of split acs/window acs/tower type acs/water coolers/ros and all related parts/accessories of regarding installations by engaging following minimum man power ac mechanic- skilled - 02 nos. helper- un skilled - 02 nos. (reliever shall be provided on weekly off/holiday) 1. contractor has to depute the above required staffs on all days including weekly offs & holidays.) 2. contractor has to provide reliever on weekly offs / holidays of above required staffs) , all inclusive comprehensive repair & maintenance contract of 1.5tr/2tr capacity wall mounted split type air conditioner unit (inverter type) working on refrigerant r-32/r-410a , including repair/replacement of compressor , pcb card , copper refrigerant piping , drain piping , control cabling , providing & top up refrigerant , providing & refixing of insulation etc(complete as required on the site for proper operation of air conditioner & all materials for replacement/rewinding to be arranged by contractor) - rates shall be quoted for 02 years for each unit , all inclusive comprehensive repair & maintenance contract of 3tr/4tr capacity tower type air conditioner unit working on refrigerant r-32/r-410a , including repair/replacement of compressor , pcb card , copper refrigerant piping , drain piping , control cabling , providing & top up refrigerant , providing & refixing of insulation etc(complete as required on the site for proper operation of air conditioner & all materials for replacement/rewinding to be arranged by contractor) - rates shall be quoted for 02 years for each unit , all inclusive comprehensive repair & maintenance contract of existing water cooler of cooling capacity 40 lph to 60 lph , storage capacity upto 120 ltrs , (including existing ro+uv (ro capacity upto 60 lph) along with water cooler) including repair/replacement of compressor , all filters , membrane , pipes/taps/sockets , cabling etc , providing & top up refrigerant , including plumbing works (complete as required on the site for proper operation of water cooler and ro+uv & all materials for replacement/rewinding to be arranged by contractor) - rates shall be quoted for 02 years for each unit , supply of required size copper pipe for suction and delivery line with all accessories suitable for 1.5tr/2tr capacity split type acs i/c control cabling etc complete as per site requirement. (make-bearing isi mark)- as and when required , supply of condensate water drain pipe bearing isi mark made of pvc having suitable size for 1.5tr/2tr split type ac units i/c necessary clamps , screws , supports , etc complete as per requirement - as and when required , shifting of existing 1.5 ton/ 2 ton split air conditioners inverter type ( including dismantling & re-installation , testing and commissioning) i/c dismantling & refixing of metal structure stand suitable for outdoor/indoor unit , refrigerant piping , power cabling , control cabling , providing sufficient insulation on refrigerant piping and all other accessories required for re- installation of air conditioner , makeup interconnection , providing & top up refrigerant , painting i/c all necessary civil works for re-installation of indoor , outddor , drain piping , cabling etc. (complete as required on the site for proper operation of air conditioner) - as and when required , installation , testing and commissioning of new 1.5 ton / 2 ton split inverter type air conditioner i/c fixing of metal structure stand suitable for outdoor/indoor unit , refrigerant piping , power cabling , control cabling , providing sufficient insulation on refrigerant piping and all other accessories required for installation of air conditioner , makeup interconnection , providing & top up refrigerent , painting i/c all necessary civil works for installations of indoor , outddor , refrigerant piping , drain piping , cabling etc. (complete as require

CTN :38863758 Due date: 29 Jan, 202529 Jan, 2025 NA
Tender For provision of 04 x fd ops room- work for 01 x fd ops room. the work consists of manufacture and supply of prefabricated mob ops room (veh mounted) of size 5.4.m x 4.80 m upto height of 2.44m and the shelter will consist of the fwg :- 2. 3. (a) the shelter would be of size 18 ft x 8 ft x 8 ft mounted on als extendable & extractable to provide hall of size 16 ft x 18 ft x 8 ft covered on three side with on end open (ref drawing no. 6) 4. 5. (b) the shelter should be mounted on flat bed als of size 16 ft x 8 ft (c) the shelter should be prefabricated and should have foldable wings for roof, floor and walls to provide a hall of size 5.4m x 4.80m x 2.44m i.e (18 ft x 16 ft x 8 ft) when all wings panel completely opened and on side of the same not enclosed. (d) opening and closing of wings should be operated through winches system manually. the base panel wings should be supported by adjustable manual jack system. (e) mechanism of opening or closing of wings will be based on operation of winches supported with manual jack system, to be functioned as under:- (i) opening the wings. the operator turns the winches handle, engaging the system to lift the top & bottom wings smoothly which are connected by steel wire rope. as the wing panels lifts, the adjustable manual jack at the base panel, are extended to provide additional support ensuring stability of the telescope structure. (ii) closing the wings. the operator when turns the winches handle in the opposite direction lowers the wing panels to closed position (see drg no 6). the adjustable manual jack can be gradually retracted to lower the base panel, ensuring controlled and smooth movement. (iii) the jack to be welded/bolted with base plate of size 300mm x 300mm x 10mm thick steel plate and the height of jack should be max of 6 openable. (iv) advantages: - (a) manual control - the winches system allow for precise manual control over the shutter movement. (ab) mechanical advantage - gears reduce the effort needed to lift or lower the wings. (ac) stable support - manual jacks provide strong and stable support for the base panel, ensuring safe and efficient operation. this mechanism of manual jack and winches system to ensure efficient, controlled, and fail safe operation of the wings. (f) tech staff of contractor to be present during assembling of shelter till its final taking over on charge by the insp team. (g) assembling and mounting of shelter on flat bed als to be provided by contractor as a onetime measure/initial demonstration till its final taking over on charge by the insp team. design criteria. (a) seismic co-efficient as per seismic zone iii. (b) wind load - equivalent to wind speed of 55 mtrs/sec as per is-875-2015 (reaff 2020). (c) roof slope -1:1.2. (d) external temperature (-) 10 0c to + 500c. (e) water absorption/penetration since, the shelter is removable and joints are not of permanent nature, flexibility in adoption of mechanism for sealing the joinery through appropriate means like silicon gel etc has been kept reserved for a later stage for optimum outcome during execution. however, the fwg mechanism would be adopted for sealing the joints. (i) rubber or silicon gaskets - rubber or silicon gaskets to be applied around the edges of the shelter panels and doors. it will be compressed to form a watertight and airtight seal when the shelter is assembled. (f) termite proofing all components of woods & puf to be treated for termite proofing. (g) ease of construction shelter should be modular in design. (h) design load as per is-875-2015 (reaff 2020)
 Loading, Please wait...

Connect us via What's Up