Get complete information related to latest Control Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Control Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Control Panel Tenders.
Tender For maintenance & operations of subway, substation, horticulture pumps, flyover underdecks, underpass, fob & related electrical installation, lt panel board, dg set & dewatering pumps under pwd emd south east.(sh:-upgradation of pumping capacity i/c replacement of discharge line, panels, cables at south ex. u turn.)
Tender For maintenance and operation of subways, storm water pumps, fobs and related electrical installation, lt panel board, diesel generator set dewatering pumps under pwd south east, new delhi
Tender For auction sale of 33 kv control pannal,11kv tpmo old damaged,33 kv tpmo,33 kv tpmo kg,copper scrap,guater pole scrap,guater pole scrap no,ocb scrap,11 kv ocb scrap,11kv pilfer unit,st pole scrap rail pole, joist pole,rs joist off size,st pole off size,rail pole scrap off size,rail pole scrap,rail pole scrap kg,steel pole scrap no,steel pole scrap,tank scrap,unload tape changer panel
Tender For corrigendum : repair/maint of external lt supply lt panel board lt switchgear overhead line and allied works at various sub stn of chcc bh sho soi pda cmdc echs and college of nursing under age e/m (hosp) under ge e/m lucknow
Tender For corrigendum : special repair replacement of vintage lt panels xlpe cable meter board and dbs meter panel board and allied wks at building no p8 of annual maintenance contract c and c under ge east lucknow
Tender For corrigendum : removing, shifting and re-erection the electrical substation equipments from 6th berth s s to proposed location thereof inside cargo jetty area - removing & shifting of the following equipments as per tech spec. no:-1, 500 kva distributions transformer., rmu of 12 kv, 630 amps 21 ka outdoor mounted rmu unit., lt panel ( way-15), re-erection, testing & commissioning of the following equipments as per tech. spec. no. 2, 500 kva distributions transformer., rmu of 12 kv, 630 amps 21 ka outdoor mounted rmu unit, supply at site 3 core armoured ht aluminium conductor xlpe cable of 11 kv grade, following rating of the as per technical specification no. 3 a). 3c x 150. sq. mm., supply at site 4 core armoured lt aluminium conductor xlpe cable of 1.1 kv grade, following rating of the as per technical specification no. 4 a) 3.5c x 300 sq. mm., supply, installation testing & commissioning at site of following 11-way lt load point panel (as per proven design) as per technical specification no. 511 ways {2 i/c, i changeover (bus coupler), 8 o/g}., laying ht/lt armoured aluminium conductor cable 3.5/4 core up to 35 sq. mm. to 150 sq. mm. as per technical specification no. 6, through hdd, with hdpe heavy duty pipe., in existing rcc trench, hard & soft soil, supply at site following way lt distribution panel (as per proven design) as per technical specification no. 715 ways (2 i/c, 1 bus coupler, 12 o/g)., installation, testing & commissioning of lt distribution panel as per technical specification no. 8, providing & connecting following type of earth wire from earth station to equipment as per requirement as per tech. spec. no. 9, 25 x 3 mm. copper strip, 25 x 3 mm. hot dip gi strip., 8 swg gi earthing wire, supply & preparation of earthing station, tfc, chemical treated back filled compound earthing system as per technical specification no. 10a) pipe-in-pipe 50-60 mm. dia. gi type 3 mtr. depth, for transformer body earth, maintenance free, supply of 3 phase 500 kva 11/0.433 kv indoor type distribution transformer as per technical specification no. 11, installation, testing & commissioning of 500 kva 11/0.433 kv indoor type distribution transformer as per technical specification no. 12, supply of tpn double door ip 42 db 4 ways distribution board as per technical specification no. 13, fixing of tpn double door ip 42 db 4 ways distribution board as per technical specification no. 14, supply of following type of mcb as per technical specification no. 15, 40a tpn mcb with 10ka breaking capacity, 32a sp mcb with 10ka breaking capacity, fixing of tpn/sp mcbs with 10 ka breaking capacity as per technical specification no. 16, providing & fixing of surface wiring with 2 x 2.5 sq. mm. copper conductor with pvc insulated (single phase and neutral) for single phase sub-circuit from the db/mcbs to the switch board as per technical specification no. 17, providing and fixing surface wiring with 1.5 sq. mm. copper conductor for light /tube point with pvc insulated single core standard copper conductor wire as per technical specification no. 17, providing and fixing surface wiring for 20a & 10a, 240 volt, 50hz power point as per technical specification no. 19, supply & installation of surface mounted 20 watt led tube light luminary complete with batten as per technical specification no. 20, supply at site 300mm sweep exhaust fan as per technical specification no. 21, fixing of 300mm sweep exhaust fan as per technical specification no. 22, supply of heat shrink straight through joint kit for 11kv, 3c x 150 sq.mm h.t xlpe cable as per technical specification no. 23, fixing the heat shrink straight through joint kit for 11kv 3c x 150 sq.mm h.t xlpe cable as per technical specification no.24, supply of heat shrink long sleeve & boat, suitable for rmu end termination kit (indoor type) for 11kv 3c x 150 sq.mm h.t xlpe cable as per technical specification no. 25, fixing of heat shrink long sleeve & b
Tender For installation , testing and commissioning of 02 nos 3.3 kv automatic power factor correction (apfcr) panel at different substation of chhal ocm, secl raigarh area .
Tender For corrigendum : ge/khu-97/2024-25 repair/ replacement of lt panel board, switch gears, bus bar, earthing, lt cable and other allied wks at khaltsi, lamayuru, hanuthang, achinathang, biamah and batalik in the aor of age b/r-ii khaltsi under ge khumbathang
Tender For corrigendum : repair replacement of damaged cable including lt panel board and connected items and repairs servicing of dg sets amf panels including repairs to swimming pool installation at wellington station under ge wellington