Get complete information related to latest Engine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Engine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Engine Tenders.
Tender For purchase of items for daikin vrf ducting ac and hitachi ducting ac and annual maintenance contract of these item .-, engine fan, , pcb card, , remote, , blower, , section discharge, , air filter, , cooling koyal copper 12 ton, , pully, , motor stand, , sensor, , belt 34 number, , pcb card, , of motor, , compressor, , low pressure, , high pressure wall, , high pressure trip wall, , condenser 24/36, out door compressor, , 05 ton, , out door conpressor 11 ton, , of motor, , damn leaves, , fan capisitor, , condenser, , gas charging, , drayer fillter, , 3 phase contector, , out door pcb, , outdoor wall, ,
Tender For providing light points, fan points, fittings, fans, power plugs, power mains and distribution boards for the construction of additional class room in second floor at division of structural engineering building, anna university, chennai-25.
Tender For bolero or equivalent vehicle (model 2024 or after) for use of assistant engineer for nodal officer simhastha-2028 project monitoring unit pwd zone ujjain. (first call)
Tender For pwd roads subdivision puthiyara,kozhikode-office building of assistant executive engineer roads subdivision kozhikode-repair work -roof, drainage modification and covering,vehicle shed etc-general electrical work
Tender For hiring -providing of vehicle one number mahindra scorpio - toyota innova -tata safari for official use of superintending engineer jal shakti hydraulic circle udhampur
Tender For r.r. damages near district industry office building at tarna distt. mandi (h.p. - providing and fixing 110mm (one hundred ten millimetre) diametre single socketed unplasticised rigid pvc rain water pipes on wall face conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm (ten millimetre) gap for thermal expansion complete within all leads, lifts carriage of material and other incidental complete in all respect as per direction and satisfaction of engineer-in-charge., providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion complete within all leads, lifts carriage of material and other incidental complete in all respect as per direction and satisfaction of engineer-in-charge., bend 87.5 (eighty seven point five degree)110mm (one hundred ten millimetre) bend, providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion complete within all leads, lifts carriage of material and other incidental complete in all respect as per direction and satisfaction of engineer-in-charge., socket 110mm (one hundred ten millimetre), constructing brick masonry manhole in cement mortar 1:4 (one cement : four coarse sand ) with r.c.c. top slab with 1:1.5:3 mix (one cement : one and half coarse sand : three graded, crushed stone aggregate 20 mm (twenty millimetre) nominal size), foundation concrete 1:4:8 mix (one cement : four coarse sand : eight graded, crushed stone aggregate 40 mm (forty millimetre) nominal size), inside plastering 12 mm (twelve millimetre) thick with cement mortar 1:3 (one cement : three coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (one cement : two coarse sand : four graded, crushed stone aggregate 20 mm (twenty millimetre) nominal size) finished with a floating coat of neat cement complete as per standard design. inside size 90x80 cm (ninety into eighty centimetre) and 45 cm (forty five centimetre) deep including c.i. cover with frame (light duty) 455x610 mm (four hundred fifty five into six hundred ten millimetre) internal dimensions, total weight of cover and frame to be not less than 38 kg (thirty eight kilogram) (weight of cover 23 kg (twenty three kilogram) and weight of frame 15 kg (fifteent kilogram) with sewer bricks conforming to is:4885 complete in all respect including carriage of materials within all leads and lifts as per direction and satisfaction of engineer-in-charge.
Tender For corrigendum : epc project for design, engineering, supply, testing, installation , erection, commissioning & capacity up gradation of pa fan and id fan motors in 210 mw unit unit-4,5,6 stage-ii, at wanakbori tps.
Tender For provision of 1 no. diesel driven force traveller/force crusier/tempo traveller or equivalent vehicle for the use of assistant executive engineer / special maintenance / theni in theni edc
Tender For provision of 1 no. diesel driven tata sedan/tata sumo/sumo gold or equivalent vehicle for the use of assistant executive engineer / distribution / bodi in theni edc