Tender For purchase of biomechanical equipments - nord board, it should be portable and should have 2 load cell sensors per unit with easy to attach hooks pivoting 360 degrees joint improving sensor accuracy it should have knee position indicator for replication of test position in each time. should have sample rate per sensor: upto 400hz, capacity per sensor: 100 kg/980-1000n safe over load per sensor: 150kg/1500n, max over load per sensor: 200kg/ 2000n, resolution: 1n and sensitivity: 22.0+/-mv/v. should have rechargeable battery & battery life should be100 active hours approx. should have working temperature range 5-40 c. (all weather proof) latest upgradable software should have both wired & wireless connectivity connectivity through usb (wired) bluetooth low energy (ble) for ipad & iphone i.e. (wireless connectivity) should provide 4 years warranty on hardware,should be provided with latest upgradable software and free software updates. should have software available in mobile & laptop (desktop) application with cloud analytics platform applications. should have ability to collect data both local i.e. laptop and on ios devices. local software:- for data collection & data analysis locally. cloud software:- for athlete data management and analysis. local (desktop /laptop) software should be compatible with windows 10 desktop applicationios 13 or later application (ipad & iphone). should have ability to collect data of over 10000 athletes or more to choose with simple name search / grouping them. cloud analytics platform for analysis. software (application) must give real time feedback of testing. license must be valid for 4years. cloud software: - should automatically sync all data collected on local mobile and laptop application when connected to internet.o should have a dashboard to see overview of organization s athletes data and different tiles(data indicators) to see athletes within and outside threshold zones. report section:- should have port section to able to compare different groups/athletes on longitudinal data. should have ability to compare same athlete s data over the period. athletes profile:- should have functionality to enter anthropometry (i.e. upper body & lower body measurement). athletes profile should be auto sync to local application and flexibility to move across different groups or teams with in organization and functionality to pick any athlete from large pool (1000 or more athlete). should be able to setup different access to different people i.e. to physiotherapist, sports scientist and s&c trainer within the organization to secure data access.api integration:- should have open-source api code for integration into athlete management system to integrate in ams system. should have software license valid for 4years. wi-fi tablet 64gb, space grey-1year warranty (as provided by oem) - service by customer service of oem only.hsn:8471.training for installation and demonstration shall be provided at olympian balbir singh senior international hockey stadium, sector- 63, mohali, punjab., electromyography (open), the system should be supplied with minimum 16 high speed wireless emg channel with built in imu sensor. should have analog+ digital base station should have analogy output option to facilitate integration with third party hardware and software sensor should have fixed inter sensor delay of 0.5 milliseconds or less sensors should have fixed spacing between electrodes preferably less than 15 mm to avoid motion artifacts and cross-talk sensor contacts should be made up of a metal for better contact and better-quality signal should be supplied with a charging/transmitting station that communicates with sensors to get information on their charging, recording and signal strength sensors, sensor skin interface, cable, power adapter and accessories sensors facilitate emg and imu measurements emg data analysis software for stand-alone usage with live recording of at least 32 channels an
Tender For purchase of recovery and rejuvenation lab equipment - whole-body pneumatic lymphatic drainage machine (pac), key features- multi-chamber design: multiple chambers that inflate and deflate in sequence to mimic manual lymphatic drainage- adjustable pressure: adjustable pressure settings to accommodate different patient needs and comfort levels- programmable treatment: programmable treatment protocols for customized therapy sessions- user-friendly interface: intuitive interface for easy operation and programming- input voltage: ac110v/220v- power consumption: less than 400w- screen: 8-inch wide color touch screen- air pressure: 20-360 mmhg (max pressure 37.5kpa)- cooling device output temperature: 5 to -16 c- output vacuum pressure: 0-110kpa- default time: 0-60 minutes- fuse size: f3al250v- ambient temperature: 5 c to 42 c- number of air bags: 24 bags or 16 pairs atleast- treatment modes: 4 modes atleast- intensity levels: 3 levels- package size: 62x42x31cm approx- gross weight: 15 kg approxsafety features- automatic pressure adjustment: automatic pressure adjustment to prevent excessive pressure and ensure patient comfort- emergency stop: emergency stop feature to quickly deflate chambers in case of discomfort or distress- patient monitoring: optional patient monitoring capabilities to track vital signs and treatment responseadditional features- multiple treatment modes: multiple treatment modes for different conditions, such as lymphedema, edema, and post-surgical swelling- data logging: optional data logging capabilities to track treatment parameters and patient progress- portability: optional portable design for increased flexibility and convenience.certifications: ce or fda clearance
Tender For purchase of recovery and rejuvenation lab equipment - portable cold compression therapy (pac), temperature control- cold therapy range: 35 f to 50 f (1 c to 10 c)- adjustable set-point cold: provides consistent temperature across the wrap, improving patient comfort and safetycompression settings- compression levels: high (5-75 mmhg), medium (5- 50 mmhg), low (5-15 mmhg), and none- compression cycles: adjustable inflation and deflation times, such as 2-3 minutes of inflation and 1 minute of deflationtreatment options- preset programs: multiple programs withcustomizable treatment times, temperatures, and compression settings- digital timer: set treatment times up to 90 minutes or use preset programs with alternating treatment and rest cyclesdevice specifications- dimensions: 7.5" w x 16" l x 7.75" h or 190mm w x 410mm l x 200mm h- weight: approximately 7.3 lbs or 3.3 kgs- power input: 100-240v, 50/60hz or ac110-120v, 60hz, ac220-240v, 50hz- noise level: less than 50 dbadditional features- portable design: allows for easy transport and use at home, in the office, or during athletic training- intermittent compression: mimics natural muscle contractions to pump away edema and stimulate oxygenated blood flow- circumferential coverage: anatomically designedwraps provide enhanced coverage and surface contact for therapeutic treatment.
Tender For purchase of recovery and rejuvenation lab equipments - percussion massager (gun massager), key features- percussive action: a percussive action that provides rapid and repetitive strokes to muscles and tissues- adjustable speed: adjustable speed settings to customize the massage experience- multiple attachment heads: multiple attachment heads for targeting different muscle groups and areas of tension- ergonomic design: ergonomic design for comfortable grip and reduced fatigue- blue tooth integration- powerful motor with 37 pounds of stall forceperformance specifications- speed range: with at-least 3 speed variation with lcd screen display- build in led light therapy- built in biometric sensor- guided breath workbattery life usb - c chargingattachments- standard ball- dampener- thumb- micro point- wedge-to emit heat- for cold treatmentsafety features- overheat protection: overheat protection to prevent damage to the motor and ensure safe use- automatic shut-off: automatic shut-off feature to prevent prolonged use and reduce risk of injury- soft start: soft start features to prevent sudden jolts or shocksadditional features- portability: compact and lightweight design for easy transport and storage- quiet operation: quiet operation for discreet use in various settings- customizable settings: customizable settings for personalized massage experiencecertifications: ce , fda clearance, vibration platform, adjustable frequency- 15hzs to 40 hzamplitude setting- 80 watt, pmdc motor supports upto 150kgremote control operatedatleast 3 preprogrammed modes non slip platform, steam room, steam generator- power output: generator should match a steam room of appox. 50 to 200 cubic footage (6-7.5 kw)- installation location: should be installed upto 60feet away from the steam room, ideally in a closet or heated attic/basement- features: automatic flushing, aromatherapy, and energy efficiencyroom design and materials- waterproofing: apply a waterproof membrane to walls, floor, and ceiling to prevent moisture damage- tiling: use non-porous tiles like porcelain or glass, and ensure a slight slope for water drainage- flooring: choose textured or anti-skid tiles to prevent slipping- insulation: insulate walls and ceiling to preserve heat and increase energy efficiencyventilation and safety- ventilation system: install an exhaust fan, sloped ceiling, and floor drain to remove excess water and maintain air quality- door and seals: ensure a properly sealed door with tempered glass, tight seals, and corrosion-resistant materials- lighting: use waterproof, sealed light fixtures like harvia fiber optic lightscontrol panel and accessories- control panel: install a touchscreen panel to control temperature, lighting, music, and aromatherapy- seating: choose water-resistant materials for benches, and consider fold-down seats or heated seats for luxury- aromatherapy: use essential oils to enhance thesteam room experience., sauna room, sauna heater with thermostat- type: electric, wood-burning, or infrared heater.power output: heater should match sauna room with 50-200 cubic footage (5-8 kw)room design and materials- insulation: high-quality insulation materials like mineral wool or fiberglass to maintain heat and energy efficiency- wood: durable, heat-resistant woods like cedar, aspen, or hemlock for interior lining- flooring: non-slip flooring materials like ceramic tiles or wood with a textured finish- ventilation: proper ventilation with adjustable vents to control airflow and humiditysafety features- temperature limiter: install a temperature limiter to prevent overheating and ensure safety- guardrail: install a guardrail around the heater to prevent accidental contactlighting: use heat-resistant lighting fixtures and ensure proper wiring and electrical safety control unit to regulate heat, foam rollers, material and density- eva (ethylene-vinyl acetate) foam: a popular choice for foam rollers due to its durability and comfort.- high-density foam: provide
Tender For purchase of recovery and rejuvenation lab equipment - cryotherapy chamber (pac), whole body cryo therapy chamber that runs completely on electricity without need of liquid nitrogen low temperatures within the range: -130 to -140 degree celsius. multiple treatment options electric mechanical lift system ensures user s head is outside the chamber to preventexposure to cryogenic temperatures. real-time skin temperature monitoring using ir tech sensors ensuring safe and controlledcooling. smart software that manages the treatment processesthroughout each session.simple quick plug-and-play set up without requiring specialized ventilation. large uhd touchscreen for easy operation andcontrol. at least 3 media monitors for displaying mediacontent. hifi speakers for audio entertainment and ambientaudio.work on normal indian 220v at 16a or less
Tender For purchase of sports physiotherapy lab equipments - focused shockwave therapy, the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high power laser thera, it should have class iv laser solid-state it should have inbuilt protocol for different indications laser wavelength should be 808nm & 980nm for 18w it should provide laser power up to 0.500mw to 18w pick power 18w (808 nm wavelength for 8w & 980 nm for 10w) the unit should have 7 touch screen facility for use the unit should operating mode should be cw (continuous) or pulsed the unit supply with attachments: scanning laser applicator 500-550mw (class 3b) the unit supply with small and large attachments 1cm and 5cm should be provided to cover different areas the unit supply with dila (deep intratissue laser adapter) supply 2 pairs of laser protective goggles to be supplied warranty 2-year class iv laser therapy is a recent modality that is used to treat pain and promote healing of muscular tissue. the class iv deep intratissue laser therapy machine is european ce approved and is clinically proven to reduce inflammation, reduce pain and increase overall range of motion in a short therapy cycle. it is being used widely all musculoskeletal pain conditions, soft tissue injuries and a wide range of other clinical indication cdsceo device registration certificate unit supply with original trolley, combination therapy machine with vaccum, the unit should be 7 colour display with touch panel treatment encyclopaedia electrodiagnostic i/t curve number of built-in programmes 204 number of user programs 150 number of compatible 2 ultrasound heads electrotherapy parmenter 2 channel electrotherapies max constant current inpatients circuit cc mode- 10. galvanic current 40 ma diadynamic, pules, current 60 ma interferential, kotz, current, unipolar sing surge -100ma tens and sp-tens current 140 ma tonolysis 100 ma microcurrents 1000 a max. voltage in patients circuite (cv mode)-140 v treatment timer 30s 60 min. the unit ultrasound head amplitude- max. 8w for 4cm head working in continuous mode the unit ultrasound head max 12w for cm working in pules mode ultrasound therapy parameter operation frequency- ultrasound head with acoustic working frequency of 1mhz & 3.5mhz with the effective radiation area 4cm effective radiating area- 4cm max ultrasound intensity -continuous /pulse mode 2/3w/cm frequency in pules mode- 16 hz/48 hz/100 hz 24. duty factor in pulse mode 5-75%, step 5% thermal effect 2-year warranty ce european or fda usa certified with iso medical device certifications cdsceo device registration certificate unit supply with original trolley and gel bottle stand and vacuum cup stand with electrode, low frequency electro magnetic therapy, 7 colour touchscreen peration mode: program/manual a sensory indicator of the magnetic field activity- magnetic stripes treatments in dual mode setting the frequency range of the magnetic field with an accuracy of 0,01 hz using the on- screen keyboard illustrated encyclopaedia with a de
Tender For purchase of gym for strength and conditioning equipment - seal row bench pac, length minimum 1320 mm width minimum 685 mm height minimum 939 mmweight minimum 45 kg or more.frame construction 100 mm x 50 mm tubes with 11 gauge thickness.the bench height is adjustable to various positions measuring from the floor to top of the bench. the j-cups and bench underside include a plastic liner to protect the bench and the barbell for long-lasting performance.lifters can choose their optimal position. an easy to operate pop-pin adjusts the bench height in 30 mm increments offering 10 settings, starting from minimum 600 mm above the floor. lifters can choose to start with the barbell on the ground or from generous bar hooks placed 265 mm above the floor. integrated wheels for portability and easy transport.warranty minimum 10 years on structural frame, minimum 2 years on wear and tear parts and minimum 1 year on upholstery for stitches and fixing, as applicable.the quoted brand and model must have all three valid regulatory certificates: en 957-6:2010+a1:2014, bs en iso 20957-2: 2021, and astm f1749.note: the bidder/oem must possess all four valid certifications: iso 9001:2015, iso 14001:2015, iso 45001:2018, and iso 10002:2018.the vendor must provide detailed information about these certifications along with appropriate justification
Tender For procurement of electrical items under adp head 2025-26 - electrical items :, 11kv v cross arm (75x40x6 mm), [galvanized] (14.6 kgs.), 11kv top channel ( 75x40x6 mm) [galvanized] (41.3 kgs.) (1set contains 2 nos), 11kv hg fuse channel ( 75x40x6 mm) [galvanized] (41.3 kgs.) (1set contains 2 nos), support clamp for top channel 50x6 mm flat for 9 mtr 400kg psc pole[galvanized] (3 kgs.) (1pair contains 2 nos), support clamp for transformer base channel 50x6 mm flat for 9 mtr 400kg psc pole[galvanized] (3 kgs.) (1set contains 2 nos), support clamp for ab switch base channel (50x6 mm) for 9 mtr 400kg psc pole[ galvanized] (1pair contains 2 nos), support clamp & channel for ab switch handle (1 set contains 2 nos), transformer belting (50x50x6 mm) & belting support (40x40x6 mm)[galvanized] (52.3 kgs.) (1 set contains 2 nos), clamp (50 x 6 mm) for transformer base channel [galvanized] (3.2 kgs.) (1 pair contains 2 nos), earthing g.i.strip (65x6)mm2, back clamp (50x6mm) for tubular pole (gal.) 2 kgs
Tender For procurement of electrical items under adp head 2025-26 - electrical items :, gi stay set complete for d/s/s (1900x 20mm) with staywire 7/10 swg and guy insulator, gi wire no. 8 for earthing, spike earthing made of 20mm gi solid rod, gi wire no. 10 for earthing, rod type earthing (25 mm dia ms rod 3 mtr long), 11 kv stay set complete (1800x16 mm) with stay wire 7/10 swg and guy insulator, stay set complete (1800x20mm) with stay wire 7/10 swg & guy insulator (galvanised), gi pipe 6" medium duty (b class), nuts & bolt (galvanized)
Tender For supply of g.i. transmission line towers ms including hot dip galvanized bolts, nuts, earthing sets and all required accessories for 220kv 110kv mc dc line 915 mt - supply of g.i. transmission line towers (ms) including hot dip galvanized bolts, nuts, earthing sets and all required accessories for 220kv & 110kv mc/dc line -915 mt