Get complete information related to latest Iron Ore Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Iron Ore Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Iron Ore Tenders.
Tender For supply installation testing and commissioning of 01 no of table top powder xrd at school of physics smvdu kakryal katra - supply and installtion of table top powder xrd with detailed specifications as follows:, x-ray generator: max. continuous rated output: 600 w guidance based software system, voltage: 20- 40 kv with increment of 1kv / current: 2 15ma with increment of 1ma (variable voltage and current). ht stability better than +/-0.01% for mains stability +/- 10 %.x-ray tube:cu target with 1000w and k-beta filter, should be upgradable for cr, co & fe.goniometer:high precision, vertical type, goniometer with theta two theta geometry, range: -3 to +1400 or better, radius: 150mm, scanning speed: 0.01 ~ 100 degree/min, max scanning speed: 500deg/min, sollar slit(incident & receiving): 2.5 deg, incident height limiting slit(dhl): open (10mm), necessary software and hardware for diagnostics capable of checking the equipment parameters/ calibration etc.divergent slit:variable to keep the x-ray illumination of sample same from low angle to high angle of 2 theta. detector:high speed silicon strip detector, it should work in 1d mode. also fluorescence reduction mode should be available. cu efficiency 99% samples holder: glass (0.2mm) qty 20, glass(0.5mm)-qty -20, aluminum (20 mmx20 mm) hole - qty 20, low background si sample holder- qty 02software: guidance based software system software should have a provision for the following: 1) all active operations should be controllable through the software 2)simultaneous data collection and data processing facility. facilities for peak search, peak match, and pattern treatment such as data smoothing, background subtraction, 2 correction, 3d multiple pattern display, k 2 calculation and removal, integrated intensity calculation, relative intensity ratio (rir) quantitative analysis and crystallite size. xrd-rietveld analysis. hybrid search / match algorithms which combines the features of peak based and profile based, phase identification techniques. it offers improves, qualitative analysis performance which makes, identification of crystalline phase with preferred, orientation or a complex lattice deformation.computer systems:latest pc along with latest operating system (latest 8.1 or 10), laser colour printer, necessary software for operation and data acquisition, analysiscod-data base:software is compatible with cod (crystallography open database) which is available on internet. (internal /external ) chiller:suitable compact for smooth running of xrd ups: online 6kva with 30 mts. backup.installation and commissioning: the instrument to be installed tested and commissioned by representative of supplier at our premises to the satisfaction of user free of cost.training: the supplier should provide the training on site free of cost.safety:the system should be housed in a high safety standard radiation enclosure as per international norms.warranty: at least one year from the date of installation(the supplier should provide the certificate of successful installation of benchtop xrd from the head of the department of concerned government labs/ institutes. )
Tender For corrigendum : biennial contract for deployment of technical assistance supervisoryengineer service engineer for maintenance servicing of weir mineralpumps of fgd system at ntpc kudgi
Tender For armo of e and m installations at jammu airport - highly skilled supervisor , skilled , semi skilled , un skilled , highly skilled data entry operator , 1.50 sqmm single core of 90 mtr coil , 2.50 sqmm single core of 90 mtr coil , 3 core x 1.5 sqmm of 100 mtr coil , 3 core x 2.5 sqmm of 100 mtr coil , modular plate of two module , modular plate of three module , modular plate of six module , modular plate of eight module , inner plate of two module , inner plate of three module , inner plate of six module , inner plate of eight module , two module flush metal gi boxes , three module flush metal gi boxes , 16 a one way modular switch , 10 a one way modular switch , 06 a 3 pin shuttered socket , 16 a 3 pin shuttered socket , 10 a one way bell push switch , 06 amp 3 pin plug tops , 16 amp 3 pin plug tops , 16 a one way piano type switch , 06 a one way piano type switch , 20 a two in one piano type socket , 06 a two in one piano type socket , 2.5 mfd rating capacitor , 4 mfd rating capacitor , 20 amp switch socket combined with box , 06 amp switch socket combined with box , extension cord with 04 universal socket , 10 sq mm aluminium tube terminal , 16 sq mm aluminium tube terminal , 25 sq mm aluminium tube terminal , 35 sq mm aluminium tube terminal , 50 sq mm aluminium tube terminal , 70 sq mm aluminium tube terminal , 95 sq mm aluminium tube terminal , 120 sq mm aluminium tube terminal , 150 sq mm aluminium tube terminal , 185 sq mm aluminium tube terminal , 240 sq mm aluminium tube terminal , 16 sq mm aluminium in line connector ferrule , 25 sq mm aluminium in line connector ferrule , 35 sq mm aluminium in line connector ferrule , 50 sq mm aluminium in line connector ferrule , 70 sq mm aluminium in line connector ferrule , 95 sq mm aluminium in line connector ferrule , 120 sq mm aluminium in line connector ferrule , 150 sq mm aluminium in line connector ferrule , 185 sq mm aluminium in line connector ferrule , 240 sq mm aluminium in line connector ferrule , plastic insulation self adhesive tape of 1.8 cm width and 7.5 mtr. length , 9w led lamp , 32 x 16 mm pvc white trunking , wireless call door bell including bell switch , door bell suitable to operate on 230v 50 hz ac supply , 100 watt incandescent filament bulb , 2 way gang box , 3 way gang box , 4 way gang box , supply of 4 x 16 sqmm lt cable , supply of 3.5 x 240 sqmm lt cable , supply of led aviation obstruction light , supply of 80 watt round shape led bay light suitable to operate on 230 volt 50 hz supply , supply of 250 watt led floodlight suitable to operate on 230 volt 50 hz ac , supply of insulating transformer mineral oil , 12 volt, 200ah lead acid battery , 12 volt, 180ah lead acid battery , 12 volt,150ah lead acid battery , 12 volt, 42ah smf-vrla battery , supply of acb edo type 3200 a fp fault breaking capacity 65 ka , installation testing and commissioning of new acb edo type 3200 a four pole , visiting charges for synchronizing panel by stucke or allen bradley or siemen as per site , visiting charge for any modification required in plc programming by deputing stucke or allen bradley or siemens as per site , execution of the item of work as per requirement of site from the cpwd schedule of rate