Tender For corrigendum : t.e.no. gmscl/d-764/rc/2025-26 - - disposable skin stapler staple wire diameter (0.53 to 0.61 mm), 451600, iso :13485 as amended from time to timeindividually packed 5 disposable linear cutter stapler reload/cartridge in sterile pack with 55-60 mm staple length, open leg lenth/staple height 2.0 to 2.9 mm, titanium/alloy titanium staple material, minimum 2 staple row on each side. it should supplied with single compatible applicator handle in sterile pack. (they should be bis/usfda/european ce certified.), gi stapler: disposable linear cutter reload/ cartridge 55-60 mm for thin/thick tissues, 1369400, iso :13485 as amended from time to timeindividually packed 5 disposable linear cutter stapler reload/cartridge in sterile pack with 55-60 mm staple length,open leg lenth/staple height 4.0 to 5.0 mm, titanium/alloy titanium staple material, minimum 2 staple row on each side. it should supplied with single compatible applicator handle in sterile pack. (they should be bis/usfda/european ce certified.), gi stapler: disposable linear cutter 75-80 mmfor thin/thick tissues, 199600, iso :13485 as amended from time to timeindividually packed 5 disposable linear cutter stapler reload/cartridge in sterile pack with 75-80 mm staple length,open leg lenth/staple height 4.0 to 5.0 mm, titanium/alloy titanium staple material, minimum 2 staple row on each side. it should supplied with single compatible applicator handle in sterile pack. (they should be bis/usfda/european ce certified.), gi stapler: disposable linear cutter reload/ cartidge 100 mm for thin/thick tissues, 145600, iso :13485 as amended from time to timeindividually packed 5 disposable linear cutter stapler reload/cartridge in sterile pack with 100 mm staple length,open leg lenth/staple height 4.0 to 5.0 mm, titanium/alloy titanium staple material, minimum 2 staple row on each side. it should supplied with single compatible applicator handle in sterile pack. (they should be bis/usfda/european ce certified.), gi endostapler: disposable linear cutter reload/cartridge, staples 45 mm cartridge for vascular/thin tissues -2.0 to 2.9 mm, 175600, iso :13485 as amended from time to time 5 sterile packed, endostapler cartridge/reload with 45 mm staple length, 3.0 to 3.9 mm staple height, titanium/alloy titanium staple material, minimum 2 staple row on each sideit should supplied with single compatible endoscopic linear cutter stapler applicator handle in sterile pack with shaft handle should rotate freely on both direction with articulation on both side. the total length of handle with cartridge should be between 32 to 38 cm. (they should be bis/usfda/european ce certified., gi endostapler: disposable linear cutter reload/cartridge, staples 45 mm cartridge for thick tissues 4.0 to 5.0 mm, 421300, iso :13485 as amended from time to time 5 sterile packed, endostapler cartridge/reload with 60 mm staple length, 2.0 to 2.9 mm staple height, titanium/alloy titanium staple material, minimum 2 staple row on each sideit should supplied with single compatible endoscopic linear cutter stapler applicator handle in sterile pack with shaft handle should rotate freely on both direction with articulation on both side. the total length of handle with cartridge should be between 32 to 38 cm.(they should be bis/usfda/european ce certified.), gi endostapler: disposable linear cutter reload/cartridge, staples 60 mm cartridge for thin/thick tissues 3.0 to 3.9 mm, 140400, iso :13485 as amended from time to time 5 sterile packed, endostapler cartridge/reload with 60 mm staple length, 4.0 to 5.0 mm staple height, titanium/alloy titanium staple material, minimum 2 staple row on each sideit should supplied with single compatible endoscopic linear cutter stapler applicator handle in sterile pack with shaft handle should rotate freely on both direction with articulation on both side. the total length of handle with cartridge should be between 32 to 38 cm.(they should be bis/usfda/european ce certified.), gi e
Tender For corrigendum : t.e.no. gmscl/d- 763/rc/2025-26 - endotracheal tube plain 3.0 mm marking with vocal cord, 69700, is 7197 as amended from time to timehydrocephalus shunt system with becterial resistant tubing, pencil point spinal needle 25 g, 101700, (1)spinal needle with pencil point tip(2)needle have transperent grooved hub. (3)should have colour codest stylet. (4)size:27 gx3 1/2"(5)needle should have side hole.(6)should be supplied with intrducer needle., hemostatic gelatin thrombin matrix 2500 iu, 394500, containing human fibrinogen + human thrombin + synthetic aprotinin 2 ml, triple lumen central venous catheter size : 7 f 16 g/18 g 18 g length 20 cm, 466200, iso:13485 as amended from time to time1.triple lumen central venous indwelling catheter : polyurethane radio opaque with a soft tip size- 9 f 16 g/16 g 14 g length 20 cm2.introducer needle:y needle with check valve to provide a second port 3.guide wire :j- tip, kink resistance, soft tip, resilient, with length markings4.scalpel 5.dilator6.catheter holder for fixation7.fully transparent extension line with colour coded hub with white slide clamp, air tight closure at injection port8.injection cap9.must have sterile dressing, antimicrobial incise drape with, 295800, iso:13485 as amended from time to time gutter splint (free size), padded synthetic splinting with single layer synthetic 10 cm x 4.6 mtr, 959000, iso:13485 as amended from time to time padded synthetic splinting with single layer synthetic 12.5 cm x4.6 mtr, icd tube thoracostomy kit size 16, 10200, iso :13485 as amended from time to timethe kit should contain 1.sterile chest drainage tube and drainage collection bag. 2.the tube should be made up of medical grade pvc 3. size :18 french with gradation markings,4. length 45-50 cm with 2 lateral holes near tip and with radioopaque lining, with blunt tip trocar towards inner side. 5.the drainage bag should be underwater sealing with 2000 ml capacity with gradation markings on it., icd tube thoracostomy kit size 20, 7800, iso :13485 as amended from time to timethe kit should contain 1.sterile chest drainage tube and drainage collection bag. 2.the tube should be made up of medical grade pvc 3. size :22 french with gradation markings,4. length 45-50 cm with 2 lateral holes near tip and with radioopaque lining, with blunt tip trocar towards inner side. 5.the drainage bag should be underwater sealing with 2000 ml capacity with gradation markings on it., icd tube thoracostomy kit size 24, 13100, iso :13485 as amended from time to timethe kit should contain 1.sterile chest drainage tube and drainage collection bag. 2.the tube should be made up of medical grade pvc 3. size :26 french with gradation markings,4. length 45-50 cm with 2 lateral holes near tip and with radioopaque lining, with blunt tip trocar towards inner side. 5.the drainage bag should be underwater sealing with 2000 ml capacity with gradation markings on it., icd tube thoracostomy kit size 28, 34400, iso :13485 as amended from time to timethe kit should contain 1.sterile chest drainage tube and drainage collection bag. 2.the tube should be made up of medical grade pvc 3. size :30 french with gradation markings,4. length 45-50 cm with 2 lateral holes near tip and with radioopaque lining, with blunt tip trocar towards inner side. 5.the drainage bag should be underwater sealing with 2000 ml capacity with gradation markings on it., icd tube thoracostomy kit size 32, 20300, endotracheal tube plain 3.0 mm marking with vocal cord, 69700, is 7197 as amended from time to timehydrocephalus shunt system with becterial resistant tubing, pencil point spinal needle 25 g, 101700, (1)spinal needle with pencil point tip(2)needle have transperent grooved hub. (3)should have colour codest stylet. (4)size:27 gx3 1/2"(5)needle should have side hole.(6)should be supplied with intrducer needle., hemostatic gelatin thrombin matrix 2500 iu, 394500, containing human fibrinogen + human thrombin + synthetic aprotinin 2 ml, triple lume