Tender For supply of mast head light white , port side light red , stbd side light green , aft anchor light , anchor light stern white , nuccbd-ram upper light around , ram middle light , towing light stern yellow , manoeuvring-morse light , fore mast head light , cbd middle light , station keeping light , senior officer light , mast head flashing light , mast head flag distinguishing light , mast head obstruction light , aft mast head light , fore anchor light , nuc-cbd-ram lower light around , on board spares , drawings and documentation , irs class charges
Tender For bid to ras bid to ras corrigendum : supply of replacement of lt incoming panels at various locations and cable termination d d - room panel-2 as per technical spec and sow. , supply of gas operator room panel-3 as per technical spec and sow. , install, replacement, testing and commissioning of gas operator room panel-3 as per technical spec and sow. , supply of 3. 5c x 400 sq. mm aluminum cable. ss4 to gas operator room as per technical spec and sow. , laying, fixing, testing and commissioning of 3. 5c x 400 sq. mm aluminum cable. ss4 to gas operator room as per technical spec and sow. , supply of 3. 5cx 70 sq. mm aluminum cable. ss4 to fire service dept. as per technical spec and sow. , laying, fixing, testing and commissioning of 3. 5cx 70 sq. mm aluminum cable. ss4 to fire service dept. as per technical spec and sow. , supply of 3. 5c x 25 sq. mm cable. pump house 1 to pump house operator room as per technical spec and sow. , laying, fixing, testing and commissioning of 3. 5c x 25 sq. mm cable. pump house 1 to pump house operator room as per technical spec and sow. , supply part for end termination. as per technical spec and sow. , service part for end termination. as per technical spec and sow. , supply part for new earthings with 75mm ci cast iron pipe and gi flat as per is standards 3043 and as per technical spec and sow , service part for new earthings with 75mm ci cast iron pipe and gi flat as per is standards 3043 and as per technical spec and sow , supply of gi flat 25 x 6mm necessary joints with nut and bolts from earth pit to panel boards. as per technical spec and sow. , laying of gi flat 25 x 6mm necessary joints with nut and bolts from earth pit to panel boards. as per technical spec and sow. , civil works - breaking of existing concrete and excavate the cable trench up to 60cm depth provide sand 45mm thick lay the3. 5 core 400sq. mm lt 1. 1kv ss4-gas operator room , civil works - breaking of existing black top road and excavate the cable trench up to 60 cm depth provide sand 45mm thick lay the 3. 5 core 70sq. mm lt. ss4 to fire service dept. , a. foundations for lt panels at all locations, b. creation of power room for lt panels in gas operator room with al partition
Tender For corrigendum : supply of design and supply of 11 kv, 630a, 25ka,erection, testing and commissioning of 11 kv, 630a, 25ka,supply of earthed armoured,aluminium conductor xlpe power cable,laying of earthed armoured,aluminium conductor xlpe power cable,supply and making straight through joint with cast resin compound,supplying and making end termination with brass compression gland and ai.lugs,supply of control cable pvc insulated, sheathed, unarmoured, flexible copper conductor cables,laying and connectorization of control cable pvc insulated, sheathed, unarmoured, flexible copper conductor cables,supply part for maintenance free earthing system,service part for maintenance free earthing system,supply of 50x6 gi strip,laying of 50x6 gi strip,removing and dismantling of existing ht panels and shifting to store,supply and placement of 3 mm thick rubber mat. class b,supply, fabrication and installation of ms items,supply and installation shock hazard charts complete with frame and glass in english and hindi,supply and installation first ai
Tender For supply of alarm monitoring system ams with software as per tts , control panel with 15 inch ams display and yard supplied equipment in switchboard room bulk head mounted as per tts , display of 12 or 15 inch flush mounted on bridge console display size will be confirmed during detail design as per tts , power supply to the displays is either from individual 230v ups or from common 24v dc ups as per design and tts , audio visual high intensity flashing beacon as per tts , i o cards digital analog digital counter rpm rtd serial link etc network switches etc as per design and tts , alarms printer as per tts , ups with batteries cum dc distribution board of suitable capacity refer clause 8.2 as per tts , addressable fire detection and general alarm system as per tts , combination detector smoke or heat or rate of rise temperature or uv-ir or optical with base and mountings as per tts , heat detector with base and mountings as per tts , flame detector with base and mountings as per tts , indoor manual call points with mountings as per tts , outdoor manual call points with mountings as per tts , general alarm push button with cover to avoid accidental activation with mountings as per tts , sensors or switches for monitoring door status open or close as per tts , bilge level float switches as per tts , high level float switches side mounted for fuel oil tanks as per tts , high level float switches top mounted for dirty oil tank as per tts , temperature transmitter as per tts , pressure transmitter as per tts , supporting accessories wt junction boxes cable connectors glands interface converters power supply converter with auto transfer switch galvanic isolators , special cables refer clause-11 as required as per tts , obs list of spares and qty as required as per tts , special tools and commissioning spares as required as per tts , class inspection charges as lumpsum , documentation drawings certificates installation operational and maintenance manuals as per tts , service support for training testing commissioning and trials as lumpsum , any other item not included above however the same would be required for proving the system during commissioning or hats or sats as required as per tts , man day rate for deputing service engineer beyond lump sum cost due to delay beyond control of supplier