Tender For corrigendum : tender for the work of renovation and improvement of lt distribution network at nagve village, of village panchayat mauxi, in the jurisdiction of s. o. valpoi, under sub division iii, valpoi, division v, bicholim
Tender For corrigendum : tender for the work of providing new led street light fixtures at various places of v.p. guleli and v.p. khotode under s.o. bhironda and v.p. sanvordem under s.o. nagargao, sd iii, valpoi, div-v, bicholim
Tender For corrigendum : tender for the work of enhancement of dtc at chinchbhatwadi, mayem, and extension of lt line at various places for a.p.s. to 1no. ltag and 9nos. ltd connections in the jurisdiction of so mayem, sub divn i, bicholim
Tender For supply of 11kv and 33 kv outdoor oil cooled metering unit (combined ct and pt set) under south andaman division sub-division - supply of 11kv & 33 kv outdoor oil cooled metering unit (combined ct & pt set) under south andaman division sub-division., 11kv outdoor oil cooled ctpt combined unit 50hz three phase six bushing typewith three no. ct and one no. three phase vtwith hv neutral broughtout andearthed ilv 12/28/75 kvp ins class a, ref std refstd is16227- 1&4ct specification:ratio 80-40/5a class 0.5 burden 15va isf=7.5@ 40a stc 4ka time: 1 sec.vt specification:ratio 11kv/110v class 0.5 burden 100va voltagefactor 1.2 continuous/1.5 for 30 seconds vectorgroup/connection star/star (ynyn0). terminals: brass stud typeprimary terminals m12 in size with nut, plainwasher, spring washer & check nut. withoutterminal connector. minimum creepage distance25mm/kv.note :primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50hz three phase six bushing type with three nosct and single nos three phase vt with hvneutral brought out and earthed ilv 36/70/170 kvpins class a ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4ka time :1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 secondsvector group/connection star/star (ynyn0).terminals:terminals: brass stud type primary terminalsm12 with nut, plain washer, spring washer &check nut. without terminal connector. minimumcreepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50hz three phase three bushing three nos. ctsand one no. three phase vt with hv neutralbroughtout and earthed. ilv 36/70/170 kvp insclass a , ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4 ka time : 1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 seconds.vector group/connection star/starterminals:brass stud type primary terminals m12 with nut,plain washer, spring washer & check nut.without terminal connector.minimum creepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50 hz three phase three bushing three nos. ctsand one no. three phase vt with hv neutralbroughtout and earthed. ilv 36/70/170 kvp insclass a , ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4 ka time : 1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 seconds.vector group/connection star/starterminals:brass stud type primary terminals m12 with nut,plain washer, spring washer & check nut.without terminal connector.minimum creepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., transportation, transit,insurance, packagingcharges