Web Analytics Made Easy - StatCounter

Health Services And Equipments Tenders

Get complete information related to latest Health Services And Equipments Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Health Services And Equipments Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Health Services And Equipments Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :40200767 Due date: 19 Dec, 202519 Dec, 2025 NA
Tender For corrigendum : selection of agencies for providing fraud analytics services

Central Government/Public Sector

CTN :40606548 Due date: 26 Dec, 202526 Dec, 2025 NA
Tender For corrigendum : supply of automated tissue processor for transmission electron microscope

State Government

CTN :40646994 Due date: 15 Dec, 202515 Dec, 2025 54.45 Crore
Tender For bid to ras corrigendum : supply of baby care kit (icds) (q3) , baby wrapping sheet (q3) , baby cap for newborn (q3) , mother care kit (q3) , outer carry bag for mother and baby care kit (q3)

State Government

CTN :40923413 Due date: 15 Dec, 202515 Dec, 2025 NA
Tender For bid to ras supply of steel shelving cabinets (adjustable type) confirming to is 3312 (v4) (q3)

State Government

CTN :41162488 Due date: 13 Dec, 202513 Dec, 2025 NA
Tender For bid to ras bid to ras corrigendum : supply of networking active and passive components with installation c c - managed layer 3 10 gig 48 ports with 4x40g slash 100g uplink ports 2x hot swappable load sharing power supplies , managed layer 3, 24 port 1 slash 10g sfp plus ports, 4x 100g uplinks ports , managed layer 2 24x1g copper ports with 4 x 10g sfp plus ports , 10g multimode transceiver , 10g singlemode transceiver , 1g copper transceiver , 6 core multimode optical fiber cable , 96 fiber rack mount liu loaded with lc adapter and lc pigtails multimode , 6 fiber rack mount liu loaded with lc adapter and lc pigtails multimode , lc-lc multimode fiber patch cord - 3 meter , 6 core singlemode os2 optical fiber cable , 48 fiber rack mount liu loaded with lc adapter and lc pigtails singlemode , 6 fiber rack mount liu loaded with lc adapter and lc pigtails singlemode , lc-lc singlemode fiber patch cord - 3 meter , cat6 utp cable 305 meter box , cat6 24 port patch panel - unloaded , cat6 information outlet - jack for patch panel , cat6 information outlet - jack for end user , face plate , surface mount box , cat 6 utp patch cord - 1 meter , cat 6 utp patch cord - 3 meter , 42u floor standing rack 800 x 1000 mm with accessories , 15u wall mount rack 600mm depth with accessories , plb hdpe pipe 40 x 33mm , 1.5inch pvc conduit isi - lms , laying of pvc conduit 1.5inch , laying of fiber , laying of hdpe pipe 40 x 33mm , treanchless digging though hdd machine , splicing of pigtail , fixing and termination of patch panel cat6 , fixing of rack , laying of utp cable , termination of i slash o , termination of patch panel , penta scanning of utp nodes , otdr of fiber, per core , installation and configuration of switches , 3 years camc of active components and modules ) /bid number : gem/2025/b/6469342 * /dated: 22-07-2025 & & / bid document 1 / 33

Central Government/Public Sector

CTN :41194505 Due date: 15 Dec, 202515 Dec, 2025 NA
Tender For bid to ras corrigendum : supply of consumable items - tris base pack size 500 gm , tris hcl pack size 100 gm , edta disodium salt pack size 100 gm , hcl pack size 500 ml , sodium hydroxide pack size 500 gm , agarose pack size 500 gm , ethidium bromide pack size 05 gm

Central Government/Public Sector

CTN :41304494 Due date: 16 Dec, 202516 Dec, 2025 2.50 Crore
Tender For corrigendum : supply of fluroscopy machine with radiolucent table

corporations/Associations/Others

CTN :41333159 Due date: 15 Dec, 202515 Dec, 2025 NA
Tender For corrigendum : tender for empanelment of service provider for establishment of fetal anomaly scan services in various govt., medical institutions through public private partnership mode

State Government

CTN :41504605 Due date: 13 Dec, 202513 Dec, 2025 7.00 Lacs
Tender For bid to ras bid to ras supply of markin cloth (v2) (q3)

State Government

CTN :41524390 Due date: 20 Jan, 202620 Jan, 2026 3.70 Crore
Tender For corrigendum : technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system shou
 Loading, Please wait...

Connect us via What's Up