Get complete information related to latest Chemical Machinery Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Chemical Machinery Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Chemical Machinery Tenders.
Tender For purchase of civil lab equipments - equipments for lab, direct shear machine:standard compliance:the equipment shall conform to bureau of indian standards is 2720 (part 13) and equivalent astm international astm d3080.technical specifications:shear box size:60 mm 60 mm 25 mm specimen size (complete with grid plates, porous stones, and specimen cutter).normal load capacity:minimum 5 kn with loading yoke and calibrated loading hanger set.shear load capacity:minimum 2.5 kn or 5 kn with calibrated proving ring (with calibration certificate).rate of strain (shear displacement):variable speed drive with controlled displacement ranging from 0.01 mm/min to 1.25 mm/min (motorised model preferred for uniform rate control).displacement measurement:horizontal displacement dial gauge: 0.01 mm least countvertical displacement dial gauge: 0.002 mm or 0.01 mm least countloading frame:rigid, heavy-duty loading frame with corrosion-resistant finish.drive system:motorised with single phase 220 230 v, 50 hz power supply.accessories (to be supplied complete):shear box assemblyproving ring with calibration charttwo dial gaugesloading weights and hangerporous stones (2 nos.)specimen cuttertool kit, auger boring (or) any boring -soil sampling apparatus: engine type: 4-stroke, air-cooled, single-cylinder petrol engine displacement: 196 cc power output: minimum 6.5 7 hp ( 3.5 kw) maximum engine speed: ~3600 4000 rpm starting system: recoil (manual) start fuel type: pure petrol fuel tank capacity: minimum 1.5 1.6 l supported auger bit sizes: 4 , 6 , 8 , 10 , 12 , 14 (100 350 mm) bit material: heavy-duty mild steel with powder coating typical drilling depth: minimum 3.5 4 ft per bit (800 mm 1.2 m) bit coupling: quick-coupling system for easy bit replacements frame: robust tubular steel frame with ergonomic handles and vibration absorbers weight: minimum 20 22 kg (without auger bit), flow table test apparatus: dimensions and specifications as per is 9103, table top made from flat metal plate ,minimum thickness 1.5 mm, table top size:700 mm*700 mm ,with flatness tolerance of 1.5 mm.table top marked with: scribed cross at centre,lines parallel to table edges and central circle of 200 mm diameter underside of table top reinforced to prevent distortion. total mass of table top:16+_ 1kg table top base frame front and upper stops provided as per is 9103. lower front edge fitted with two rigid stops to transfer load directly to base frame. base frame designed to transfer impact load directly to supporting surface. minimizing bounce stop watch-digital -2 nos scale 1 mtr-2 nos mounting wooden platform 300 mm height amc for 3 years inclusive., drying oven:temperature range: ambient (room) up to 250 temperature control: digital pid controller / thermostat for accurate heating. prestogroupaccuracy: typically 1 2 c. chamber material: stainless steel inner chamber for durability and easy cleaning. air circulation: forced convection fan for uniform temperature. shelves: usually 2 3 adjustable shelves. power supply: single phase 220 230 v ac, 50 hz.
Tender For replacement of automatic chlorine dosing machine & repairing of mcc panel at tw-i of denkua w/s scheme (mvs), under sutahata block in the dist. of purba medinipur under midnapore mechanical division. p.h.e. dte
Tender For corrigendum : providing of custom bid for services - 200153354 hiring operation and maintenance of chlorine dioxide system in pt clarifier and cw-i ii and iii at ntpc ramagundam
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - manufacturing unit; complete re-rubber lining of crystallizer tank (c-1) in phosphoric acid plant at rcf, trombay unit as per sow and nit; as per sow and nit
Tender For corrigendum : rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have cont
Tender For bid to ras providing of custom bid for services - unloading and disposal of synthesis converter, hts, lts shift converter and methanator catalyst in ammonia plant
Tender For corrigendum : supply of fabrication and erection work e e - places , replacing wornout runner base and installing a new runner base of cane carrier and baggage elevator and r b c , replacing wornout runner with new one of cane carrier and baggage elevator and r b c , removing wornout angle iron and t iron of the cane carrier and reinstalling it by straightening the crooked part , removing the wornout part of the suit from different places and fitting it with new one , chevron grooving of new rollers of the mill , chevron grooving of old rollers of the mill , remove the wornout partition plates of the juice box above and below the juice heater by 10 or 12 mm ms plate and install it , installing ribs at the top and bottom partitions of the juice heater , repairing save all of qurdbody , removing old wornout gutters installed at various places and installing it with new gutters , remove the old wornout save all from pan and quard and install it with new one , reinstalling the new umbrella fitted inside the pan by making a new one and removing the old one , replacement ribbon arm of the mascute receiving crystallizer , making new separator of a centrifugal machine , removing the wornout truff of the hopper and installing it with new one , making and installing new separators for continuous centrifugal machines , removing the tubes of quad juice heater and dynamic juice heater and expanding them by installing new tubes and giving their hydraulic testing satisfactory of size 42 mm , removing the tubes of pan installing new tubes and expanding them and giving hydraulic tesing with satisfactory trial of size 96 mm , removing the wornout flue gas ducting of both the boilers and installing it with newone making from new or old plates , removing the wornout front and roof plate at boiler number 1 and 2 and installing with a new plate , removing the damaged boiler damper and installing a new one , making bagasse suit and installing. , replacement of juice over flow box of clarifier , making and installing bed of motor and pumps at various places as per requirement , replacement 6 inch dia cooling pipe of sulfur furnace , removing the monitor casing of a machine from old machine and installing it and giving its a trial , making amd replacing manholes at various places , making and replacing the enternals of cather of the pan. , making and replacing the new hood of cane cutter , removing the old bottom plate of the lowest compartment of the clarifier and placing a new plate on it after placing an angle trap as per the instructions and giving a satisfactory water trial , reinstalling the stirrer of the clarifier and giving a satisfactory trial , removing the shaft of a pug mill and replacing the old bushes on both sides and fitting new ones , removing and refitting the shaft of a brown sugar magma mixer and installing with new bush , reinstalling the trufff of connecting rod of the hopper , making and installing new catcher strainer , removing the old rail line of the trolley of the unloader and fitting the new rail line satisfactorily and doing water level , reinstalling the old rail line of the unloader s bridge and fitting it and checking water level etc , removal of old and weak channels of 3 inches to 10 inches diameter installed at various places and installation of new ones as per requirement , cutting and straightening old plates installed at various places as per requirement , removal of old and wornout scrubber installed on sulfur furnace and making and replacing with 8 or 10 mm plate and making all the connections , removing the trufff plate including support corroded shell and top cover plate of the top chamber of the clarifier and fitting the new plate and giving it s a water proof trial , re-installation alignment and //bid details 2 / 47 trial of hopper driving end , making and installing the top cover of the centrifugal machine , making an arm and installing it on the shaft of pug mill , making and installing scrubber and bot
Tender For sale of unserviceable articles and scrap materials. micro wave oven , servo stabilizer 5 k.v.a vs05 , gc-3 genei cooler 24 * 0.5ml tube , flash gel system sr.no. 107573 with flash gel sr.no. inz/1021 (electrophoresis camera system) , pcr machine (sr no. 482-1513) with 1 k.va uos (sr no. es1101208110) with 9 batteries , autoclave vertical 300 * 500mm li-13 (sr.no. 43110) with automatic pressure control switch and accessories , spin win 6 plate rotor , mini submarine eletrophoresis with casting tray, comb set (15 * 10cm) , electrophoresis vertical mega gel 50 cm (wx) with accessories , referigereator , li control , ph meter , ph meter , elico make , ph meter digital eutech , tutor d two pen type , ph meter , distillation unit ysu-410a, yorco make , laminar air flow (yorco) dm-188-hl-62 (6'x2'x2) with accessories , weighing balance labex fuji digital up to 3.kg model no li-303 g , weighing balance and/ek-400i, 400gxo.lg , rotary mixer rotospin (tarson) , model no. 3090 , 3091 50x1.5 ml , 3092 20x1.5ml , autoclave vertical ys1 402d 300x500mm , water bath liquid cooling microprocessor , controlled l1-133 , 500 * 250 * 250mm , micro centrifuge with rotors non refrigerated , remi/rm-12cdx , angle head (30x.4ml) rm1241,rm1242 (24 * 1.5ml) 1261(8 * 2ml) , refrigerated centrifuge , no.c-24bl , rotors , a) angle head c-244a (8 * 15ml) , b) angle head r-247 (8 * 50ml) , spectrophotometer (uv visible) digital 200-1000nm , transluminator 25x25 md-25 wealtech , uv lamp held 300nm, 230v / 50 * hz , platform rocker 11 platform electronic timer genei make no.107107 , genei digital p5500 power supply with timer constant with current constant voltage digital display (genei no 1061817) , pipette carosuet for 6 pipette3115000003 , alpha image ep gel documentation and analysis system make alpha innotech cat no 92-13822-00 , spinwin mc 8x200 l 11)1.5 ml tube , fume hood j-14 mfh1260 sonar , glass water distillation unit (scientific and laboratory instrument (paridhi polymer) cat. no. 141-a/mqd-2p-b/qxl-rsh , deep freeze -80 c model no urc-u-270-4 , volume 2701 , gel electrophoresis (horizontal) merck genei bgps 300/400 with power supply genel , gelelectrophoresis (vertical) merck with power supply genei