Tender For corrigendum : tender for supply of equipment material design erection testing commissioning for sop to ms shyam indus pvt ltd co prittam singh at vill baghni by prov 1104kv 25kva sstn aw 3ph lt line in vill baghni in e section bhadwar under esd hpsebl nurpur. t - 25 kva trsanformer, prov. distribution transformer (ordinary), 11/0.4 kv, 25 kva ., prov. steel tubular poles (9 m, working load > 200 kgf/m ) ., prov. muffs with concerete filling, prov. x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos] for incomer line, prov. ms angle iron (50x50x6 mm), length: (2800 mm) x1 nos for las, prov. x-arm: [channel iron (75x40x6 mm), length : (2800 mm x 4 nos] for supporting do fuse unit & go switch, prov. transformer bed, belting & knee bracing, prov. x-arm: [channel iron (100x50x6 mm), length : 2800 mm x 2 nos] for transformer bed, prov. x-arm [channel iron (100x50x6 mm), length : (460 mm) x 2 nos for supporting main channel of transformer], prov. ms angle iron (50x50x6 mm), length : (2800 mm) x 2 nos, prov. ms angle iron (35x35x5 mm), length : (460 ) x 2 nos, prov. ms angle iron (50x50x6 mm), length : (950 mm) x 2 nos for bed knee bracing, prov. transformer lt distribution box and go switch fixing assembly, prov. ms angle iron (50x50x6 mm), length : (2800 mm) x 2 nos, prov. ms angle iron (50x50x6 mm), length : (450 mm) x 1 nos, prov. go switch handle supporting: [channel iron (75x40x6 mm), length : 460 mm, prov. go ab switch unit (11kv, 400a, 25 ka ) tripple pole o/d type, prov. d.o fuse unit, prov. lighting arrester, 9 kv station class (porcelain type), prov. discs insulator sets (comprising 1 no. disc: ^^(porcelain, bs, 12 kv, 90 kn) including dead end clamps etc.), prov. stay set complete, prov. stay wire (7/3.15 mm) (6.0 kg per stay set), prov. pipe earthing set, prov. lt distribution panel box with mccb(160a, 10ka, 4p, 1no) & sfu(32a, 5no, rewirable), prov. half clamp (m.s. flat 50x6 mm), prov. full clamps (m.s. flat 50x6 mm), prov. nuts and bolts of various sizes (galvanised / coated) [preferably 16 mm or more (with flat and spring washers)], prov. aluminium thimble, prov. copper thimble 35 amp, prov. danger plate, prov. barbed wire, prov. lt cable (3.5 core) 50 mm , prov. energy meter 3- , 4 wire ct operated static tri-vector meter with box(ct-100a), prov. aluminum paint., prov. 6/1/3.35, 50mm ., prov. construction of foundation of transformer, erection of 25 kva s/stn. i.e. digging of pit for pole & earthing two no. poles & 3 nos. for earth drilling of holes in x-arms, preparation of plateform str. members c.i., a.l. i.e. x-arms & k.b. set, errection of d/p, concreating of rcc muff errection of plateform, errection of x-arms, d.o., l.a., mccb, switch lt box, energy meter, errection of transformer, earthing connection to g.o. switch, transformer l.a. etc., errection of stay set, jumper, pipe earthing 3 nos set, l.t. cable, barbed wire and painting complete in all respect., transportation charges @10490/-, prov. transportation charges & mannual carriage of 25 kva pole mounted distribution s/stn. (line length 0.500km), erection of 3- ph. lt line, prov. aaac (7/3.15 50mm ) { neutral conductor including 1% (sag, jumpering and wastage}, prov. steel tubular poles (8 m, working load > 200 kgf/m )., prov. muffs with concerete filling, prov. shackle insulator with d-iron, prov. lt stay set i/c egg insulator., prov. nuts and bolts of various sizes (galvanised / coated) [preferably 16 mm or more (with flat and spring washers)], prov. stay wire, prov. g.i wire no 8swg, erection of 8 mtr. st pole single structure i.e. digging of pit, fixing of insulator, x-arms, k.b. set, top clamp, barbed wire, danger plate, drilling of holes and filling of pit + ramming complete in all respect., sagging of conductor i.e. laying, stringing and sagging & binding with insulator (single wire per km)., sagging of g.i i.e. laying, stringing and sagging & binding with insulator (single wire per km)., erection of stay
Tender For tender for maintineance of 33 kv 11 kv ht and lt lines by cutting looping of tree branches bush cutting and mantained the line complete in all of respect inclusive of stay tightening strenghening of pole sagging and tightening of conductor jumprin
Tender For tender for mainteneance of 22 kv kv ht lt lines by cutting, looping of tree branches bush cutting and mantained the line complete in all of respect inclusive of stay tightening strenghening of pole sagging tightening of conductor jumpring etc to prov
Tender For tender for mainteneance of 22 kv ht lt lines by cutting, looping of tree branches bush cutting and mantained the line complete in all of respect inclusive of stay tightening strenghening of pole sagging tightening of conductor jumpring etc to provi
Tender For corrigendum : supply of led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3) (under bis scheme - ii) (q2) , pvc insulated copper cable single core and multi core circular sheathed with flexible conductor (v2) isi marked to is 694 (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , bayonet lampholders (v2) isi marked to is 1258 (q2)
Tender For corrigendum : supply of led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3) (under bis scheme - ii) (q2) , pvc insulated copper cable single core and multi core circular sheathed with flexible conductor (v2) isi marked to is 694 (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , bayonet lampholders (v2) isi marked to is 1258 (q2)
Tender For supply of vrf or vrv air cooled outdoor units suitable for cooling or heating having 100 percent hermetically sealed inverter type twin rotary or scroll compressor capacity of machines 14 hp to 22 hp , following minimum capacity 4 way vrv or vrf cassette type indoor ceiling mounted unit equipped with synthetic washable media pre filter,3 point 2 tr , following minimum capacity 4 way vrv or vrf cassette type indoor ceiling mounted unit equipped with synthetic washable media pre filter,4 tr , vaccumiazation and nitrogen testing of following nominal sizes of soft or hard drawn copper refrigerant piping for vrv or vrf system, thickness 1 point 2 mm , 9 point 5 mm dia od soft drawn with tube thickness 1 point 2 mm , 12point 7 mm dia od soft drawn with tube thickness 1point 2 mm , 15 point 86 mm dia od soft drawn with tube thickness 1point 2 mm , 19 mm dia od hard drawn with tube thickness 1 point 2 mm , 22 point 2 mm dia od hard drawn with tube thickness 1 point 2 mm , 25 point 4 mm dia od hard drawn with tube thickness 1 point 2 mm , 28 point 58 mm dia od hard drawn with tube thickness 1 point 2 mm , 34 point 9 mm dia od hard drawn with tube thickness 1 point 62 mm , 41 point 27 mm dia od hard drawn with tube thickness 1 point 62 mm , s i t c of y joints kit refrnet , drain piping rigid pvc piping complete with fittings supports as per specifications and insulated with 6mm thick closed cell elastometric nitrile rubber insulation 25mm dia and , 32 mm dia , 40mm dia , control and transmission wiring , testing and commissioning of vrf or vrv systems including topping of r410a gas as per site requirements , supply and installation of u or v protection of used copper pipe at outer site for odu connection site , 6way load bank double door enclosure confirming to is 8623 iec 60439 g frame panel boards , supplying and fixing of following sizes of medium class pvc conduit along with accessories 25mm , frlsh or hffr pvc insulated copper conductor single core cable in the existing surface or recessed steel or pvc conduit as required 3 x 1 point 5 sq mm , suitable size gi box with modular plate and cover in front on surface or in recess , one number xlpe insulated and pvc sheathed copper conductor armoured power cable of 1 point 1 kv grade 4 x 16 sqmm , 16 a rating 240 by 415 v 10 ka c curve miniature circuit breaker suitable for nductive load of following poles in the existing mcb db complete with connections single pole , single pole and neutral sheet steel mcb distribution board 240 v on surface by recess complete 12 way double door , supplying and fixing 25 a rating single pole and neutral , following size of perforated painted with powder coating m s cable trays 150 mm width x 50 mm depth x 1point 6 mm thickness , earthing with g i earth pipe 4 point 5 metre long 40 mm dia including accessories , providing and laying earth connection from earth electrode , providing and fixing 6 swg dia g i wire on surface or in recess for loop earthing , amc as per section c , installation of cassette ac 2 ton 5 star , copper pipe , 4 core copper wire , drain pipe with insulation , odu stand , cable tray , hanging rod , faster nut , wrapping tape , 3 core copper wire