Get complete information related to latest Refrigerator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Refrigerator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Refrigerator Tenders.
Tender For request for expression of interest (eoi) supply, installation, testing, and commissioning (sitc) of oem-supplied mortuary cabinets constructed with ss 304 grade materials at imsf, iisc campus, bengaluru
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - cold room storage at blo under ge gomantak; repair/replacement of compressor of cold room storage at blo under ge gomantak; service provider
Tender For corrigendum : - repairing of damaged electrical items and supply of different electrical maintenance materials at 44 iron side road rhe. - repair of existing damaged led tube light / led mirror light/ led cove light/ led surface mount+ down lighter light with necessary driver should matching with existing specification (t5 output_ 18w 20w, 240ma)i) driver only, ii) led strip only, supply of 4ft long led smart bright tube light fitting with led tube light .(make: philips-type: bn 021 led40s- 6500 psu gr (4 ft) or equivalent model of crompton/jaquar)., supply of single fancy wall bracket led light fitting (make - philips, model no-31453 or equivalent model of crompton/jaquar) incl. 1nos 9 w led lamp (make:-philips or equivalent model of crompton/jaquar). of warm white colour lamp complete with all accessories, supply of 15 watt led surface mount+ down lighter light fittings including all accessories and mountings complete set as per direction of eic(make- crompton, type-lcdspln-r-15-cdl/ philips/ jaquar), supply of led 7.5 watt mirror light fittings complete with lamp including & all other accessories (make :philips:type jojoba wall light, model no. 34034/14/86 or equivalent model of crompton/jaquar)], fixing of 3 module 2w, 3000k led foot light fittings. incl. s/f 3 module ms flush box in wall as per approval of eic/authority., supply of single led light 12w, 1200 lm, 10,000 life hours, cdl led lamp ( make : philips / crompton / jaquar ), supply of modular soket type 2 module regulator (brand approved by eic), supply of step type electronics fan regulator (brand approved by eic), supply & fixing 1200 mm ceiling fan(max 60w) complete with all accessories, down-rod etc. (except regulator) [make:orient new air plus/crompton/usha striker plus /havells (cat no-fhcss1sbrn48)/ as per approval of eic.], supply of 450 mm sweep cabin fan (make:orient tornado wall ii or equivalent model of cg/havells/other brand as per approval of eic/authority] on wall by s&f rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd., supply of 09 sweep a.c. exaust fan metal body with all parts.make-epc, type-p23009/4(make : havells / orient / epc), supply of 200 mm sweep, modular exhaust fan (max 32w) complete with all accessories, [make:havells ventil/crompton/usha / as per approval of eic.], supply of 10ltr geyser having storage ; capacity: 10 litres; wattage: 2000 watts; pressure: 8 bars ; bee rating: 5 star; waterproof degree : ipx-4 protection for longer product life. adjustable knob for temperature settings between 25 degree c to 75 degree c to get the desired temperature, multi-function safety valve which protects tank from internal and external pressure build up including hot & cold water distribution pipe line. warranty- 2yearsmake:- havells(type- monza)/ venus/ v-guard, supplying of 1.1 kv single core stranded fr 2.5 sqr mm pvc insulated & unsheathed single core stranded copper wire (brand approved by eic) 100 mtr coil, supplying of 240v 6-16a sp mcb of breaking capacity 10ka & c characteristics (make: l&k / legrand / crabtree), supplying of 240v 40a dp mcb isolator(make: l&k / legrand / crabtree), supplying of 240v 63a fp mcb isolator(make: l&k / legrand / crabtree), supplying of 2.5 mfd condenser (tibcon), add. g.s.t.@ 18% (on total from item no 1 to 20) to be calculated by bidder, add. lwc.@ 1% to be calculated (on total from item no 1 to 20 + gst@18%) by bidder
Tender For supply of refrigerator ,deep freezer ,hot air oven ,bench top autoclave (automated) ,air conditioner ,stabiliser for air cond6t60ner ,bottle sealer with foil for sealing bottles ,printer and water proof labels
Tender For rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have continuous reagent