Tender For corrigendum : tender for supply of electrical consumable and miscellaneous items for hurl sindri c - cable tie, lock type cut to open, colour-white, thickness-2.5mm, length-100mm, material nylon 66, pack size 100. cable tie, lock type cut to open, colour-white, thickness-2.5mm, length-200mm, material nylon 66, pack size 100. cable tie, lock type cut to open, colour-white, thickness-2.5mm, length 300mm, material nylon 66, pack size 100. electrical contact cleaner spray, quick dry, packing size for liquid(ml)-500ml galvanized zinc spray, finish type-bright silver, zinc-enriched coating to repair surface damage protection against corrosion, special feature-rust resistance, packing size for liquid(ml)-500ml. silica gel, colour of silica gel-blue, particle size -9 to 12 mm, air tight container for packing of silica gel-plastic. silicon sealant, physical state- viscous paste, appearance-translucent/ opaque, color-clear/black/white/gray, surface cure-5-10 min, packing size(ml)-300ml m-seal, shelf life 12 months, hardness 75-80, impact strength - 2.5 * 3kg / c * m setting time at 30 deg c min-60 min, working temp limit 80 deg. c component resin and hardness, packaging size-1 kg gap filling pu foam spray(puf seal), application fill the gap between wall & tray, conduit pipe and wire sealing, packing size for liquid(ml)-750ml. silicon sealant gun, feed type: push-fed gun, type: cordless-corded glue gun pvc tape, material pvc, adhesive-rubber bases adhesive, adhesive side- single side, temperature range (-40 degree c to 125 degree c), colour red, length-6.5 mtr, voltage resistance- upto 600v. pvc tape, material pvc, adhesive- rubber bases adhesive, adhesive side- single side, temperature range (-40 degree c to 125 degree c), colour yellow, length 6.5 mtr, voltage resistance-lipto 600v. pvc tape, material-pvc, adhesive- rubber bases adhesive, adhesive side-single side, temperature range (-40 degree c to 125 degree c), colour blue, length 6.5 mtr, voltage resistance-upto 600v pvc tape, material -pvc, adhesive rubber bases adhesive, adhesive side- single side, temperature range(-40 degree c to 125 degree c), colour-black, length 6.5 mtr, voltage resistance- upto 600v. pvc tape, material pvc, adhesive-rubber bases adhesive, adhesive side- single side, temperature range (-40 degree c to 125 degree c), colour green, length 6.5 mtr, voltage resistance upto goov ht-tape, self bonding electric tape, for high-voltage(upto 69kv), corona and ozone resistant, moisture and corrosion resistant, overload temperature 130 deg. c. roll size 9.15 meters. teflon tape, packing type-piece, elongation % 50-60, length of tape-9 mtr, application of colour tape white al foil tape, color-sever, type-aluminium foil tape 2 inch, cello tape type single sided, tape dispenser type-high bond, self adhesive, cello tape roll size-15 meters waste cotton doth emery paper, grit size grit 40-60, material emery, form-belt, bonding type-resin, coat type-open coat, suitable material mild steel, stainless steel. roll length-40 inch. emery paper, grit size-grit 220-400, material-emery, form-belt, bonding type-resin, coat type-open coat, suitable material mild steel, stainless steel roll length 280 mn trubble gum, strong glue trap, type- glue board, container type-sachet, protection against-rats titanium putty, 1 kg 1.5 sq.mm ring type lug, insulated type, rated voltage-upto 1100v, material copper, minimum pack of 200 2.5 sq.mm ring type lug, insulated type, rated voltage-upto 1100v, material copper, minimum pack of 100 4 sq.mm ring type lug, insulated type, rated voltage-upto 1100v, material-copper, minimum pack of 10 1.5 sq.mm pin type lug, insulated type, rated voltage-upto 1100v, material-copper, minimum pack of 200 2.5 sq.mm pin type lug, insulated type, rated voltage-upto 1100v, material copper, minimum pack of 20
Tender For supply of cable duct (cable tray -length 3 mtrs) to drg.no.lw44174, item-4 alt. 'c'. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply & lnstallation of under frame cable duct & pipe mounting to drg. no. lwsczac7-l-002/col-l & ii. alt. j. for lwsczac, lwfac, lwcbac, lwaccw,lwaccn coaches. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of cable duct a 45 cover,in standard slot grey, as per drawing: cat no cda45sg,packing instruction: as per standard packing. it should be ensured that item should not rub during transportation. the item should be packed with adequate strength. transit damage , if any , shall be at the cost of supplier. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For tikkar block: morni panchayat: tikkar dist.: panchkula annual maintenance work for water supply - na gi pipes providing and fixing g.i. pipes complete with g.i. fittings including trenching up to 0.30m to 1.00m depth and refilling etc., na water supply, sewerage and drainage works providing and fixing g.i. union in existing g.i. pipe line,cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall.
Tender For bid to ras providing of repair and overhauling service - l-161, l-163 & l-244 - fabrication of wooden box, securing arrangement of 10 pdb & fabrication of supporting bracket and cable tray mat aluminium; l-161, l-163 & l-244 - fabrication of wooden box, securing arrangement..
Tender For special repairs to lt panels and connected items at pyro, pinaka, nag mixture building, magazine area and ap building in hemrl, pune - taking out old serviceable/unserviceable lt panel/capacitor panel of any description or capacity keeping aside in safe custody for schedule of credit complete all as specified and directed, supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 nos, (c) mccb 4p, 125 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 200/5 - 04 nos, (e) control mcb c curve, sp, 6 to 32a, 10ka, c curve - 02 nos, (f) led phase indicator (r,y & b) - 01 set. (pyro sub stn), supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (c) mccb 4p, 315 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) mccb 4p, 250 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 nos (e) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 800/5 - 04 nos, (e) con
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl