Get complete information related to latest Water Purification Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Purification Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Purification Tenders.
Tender For corrigendum : supply of tata 1613 filter kit cummunis bs-iii fuel filter 252509120239 tata oil filter 27861813902 , filter kit cummunis bs iv fuel filter f002h22095bosch oil filter , air filter element set , pressure plate 352 mm , clutch plate 352 mm , pressure plate 330 mm , clutch release bearing , clutch servo 90 , c m c assy , u j cros , canter bearing with rubber , brake shoe lining set front , brake shoe lining set rear , brake shoe lining set front with rivets , brake shoe lining set rear with rivets siv , fan belt set 8pk 1250 980 , starter motor 26024055a 24v , head light set l r new modal , tail light set l r new modal , solenoid switch 24v , gear box sensor assy , cabin shocker cabin cylinder , cabin hyd pump assy , side indicator set l and r , armature assy 24v bsiii , armature assy 24v bs iv , horn 24 v , 4 pin relay 24v , battery terminal , battery terminal plus , fog light set , head light tube 24v , fly wheel assy with fly ring 138 teeth , hub seal kit front , hub seal kit rear , radiator assy , radiator tank reservoir , radiator hose pipe set , fan belt bsiii , brake booster front wheel , brake booster rear wheel , head gaskket , rear view mirror l r , clutch plate 330 mm dia , chevrolet tavera rear brake shoe rbl 1010 , clutch set 65225050002c , front disc rotor 29390004 , alternator belt xu15 1017 , accelerator cable 3501 , front wheel bearing outer 48548 , front wheel bearing inner 12649 , fuel filter housing t97690400 , fuel filter line , center pin gmf9118 , front shocker am s 700193 , rear shocker am s 700186 , water pump assy wp140 , upper clutch cylinder assy cs541 , lower clutch cylinder assy cs542 , front suspension bush kit vr 1401 , rear bush kit , torsion bar bolt sisco 1422 with nut assy , thermostat valve , water hose pipe clump , wheel cylinder rear mew 2701 , stepny securing assy ci 5716 , hub stud with nut , clutch relase bearing , brake master cylinder with booster , steering coupling , front disc pad taver , front suspension kit major with ball joint tie rod end , shaft cross , center rod tavera , wind shield sefety glass tavera laminator , filter kit oil filter fuel filtr , air filter , wipper set tavera , head light tavera lh new model , haead light tavera rh new model , head light tube 12v , tail light set rh , tail light set lh , horn 12v , starter motor self , mohindra bolero camper gold zx wind shield glass front , mohindra bolero camper gold zx tail light set l r , tata winger ambulance filter kit oil filter , front disc pad , maruti swift dzire 2018 patrol box assy steering gear , maruti swift dzire 2018 patrofront shocker assy set l r
Tender For provision of roof top on grid solar plant at various stations over nagpur division i.e. krth, taku, kqe, doh, pox, gdya, bzu, par, nrkr, katl, kswr, ngp, kri, aq, dmn, wr & plo etc.
Tender For corrigendum : provision of roof top on grid solar plant at various stations over nagpur division i.e. krth, taku, kqe, doh, pox, gdya, bzu, par, nrkr, katl, kswr, ngp, kri, aq, dmn, wr & plo etc.
Tender For supply of adblue inlet line filter (urea tank strainer) (part no: 5h.999.28.0.sp) [ warranty period: 12 months after the date of delivery ] ]
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - wt-5196g - (bmd-6) work of rubber lining of various equipments, pipes and fittings for dm plant and cpu plant of utps unit 3 to 6 on as and when required basis; as per s..
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - wt-5182g (bmd-ii) rate contract for the work of online, preventive and breakdown maintenance for dm plant on as and when required basis for unit no 3, 4 & 5 at gsecl uka..
Tender For bid to ras providing of operation and maintenance of effluent/sewage treatment plant - complete system; as per scope of work; under annual maintenance contract and functional
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole
Tender For repair to water supply distribution network including disinfection of water supply at various pump house and repair to various submersible pump, booster electric control system at af station chandigarh under ge (af) chandigarh
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep