Web Analytics Made Easy - StatCounter

Aa Conductor Tenders

Get complete information related to latest Aa Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aa Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aa Conductor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45719686 Due date: 13 Jul, 202613 Jul, 2026 44.90 Lacs
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl

Central Government/Public Sector

CTN :45475154 Due date: 07 Jul, 202607 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get

Central Government And Public Sector

CTN :45717394 Due date: 21 Jul, 202621 Jul, 2026 NA
Tender For supply of hydraulic compressor capacity - 100t with one set die suitable for aac conductor 240 sq. mm (hyd. compressor new improved with remote hand operated double action hyd. pump fitted with 2 m hose and pressure recording gauge ) as per annexure - a. [ warranty period: 30 months after the dateof delivery ] ]

State Government

CTN :45715152 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For estimate proposal for erection of 5km new 11kv feeder to vennacherla village from 33/1ikv nakkalapally ss which involves stringing of 5km of 11kv scoh line with 55sq mm aaa conductor along with crection of 1no. feeder vcb at 33/11kv nakkalapally ss in peddakothapally section in kollapur sub-division of nagarkurnool division of nagarkurnool circle under t&d improvements to original works

State Government

CTN :45715153 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For estimate proposal for erection of 5km new 11kv feeder to vennacherla village from 33/11kv nakkalapally ss w uch involves stringing of 5km of tikv scoh line with 55sq.mm aaa conductor along with erection of 1no feeder vcb at 33/11kv nakkalapally ss in peddakothapally section in kollapur sub-division of nagarkurnool division of nagarkurnool circle under t&d improvements to original works,

Central Government/Public Sector

CTN :45365822 Due date: 06 Jul, 202606 Jul, 2026 39.99 Lacs
Tender For corrigendum : repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches

Central Government/Public Sector

CTN :45689739 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of tee connector for quad aac bull to quad aac bull-branch way-t1 point at drawing page 1 , pg clamp for single aac bull to single aac bull , pg clamp for single aac bull to single aac bull for kurnool , pg clamp for single aac bull to single aac bull for nellore , terminal connector suitable for quad bull aac conductor to 4.5inch ips al. tube-horizontal approach

corporations/Associations/Others

CTN :45698715 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For auction sale of empty oil barrel scrap (205/210 ltr.),pvc armoured service cable scrap & pvc alu. wire scrap,iron, cast iron scrap & g. i wires and g i scrap all types,1 phase plastic static meter & 3 phase plastic static meter scrap,ht abc cable scrap & lt abc cable scrap without messenger wire,transformer scrap - 11 / 100 kva alu. winding crgo,aaa conductor , acsr conductor ,copper conductor, aluminium scrap(misc.)

State Government

CTN :45676279 Due date: 03 Jul, 202603 Jul, 2026 36.54 Lacs
Tender For annual repair and maintenance of iei and eei to g.b. pant hospital at atlanta point wsd, apwd in svp. sw supply of labour and electrical items for iei and eei maintenance in g.b. pant hospital, svp - supply of following category labour to asssit wireman/assistant wireman in iei and eei maintenanceun-skilled, supply of following electrical for iei & eei maintenance work.1.5 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, 4.0 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, 6.0 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, 10.0 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, 16 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, modular one way switch 5/6 a , similar to indoasian /roma/ziva, modular one way switch 15/16 a , similar to indoasian /roma/ziva, modular socket 5/6 a ,3 pin ,similar to indoasian /roma/ziva, modular socket 6/16 a ,3 pin ,similar to indoasian /roma/ziva, modular fan regulator 2 module ,similar to indoasian /roma/ziva, pvc batten holder, call bell/ buzzer, single phase, modular surface box 3-way with cover plate and frame similar to indoasian /roma/ziva, modular surface box 6-way with cover plate and frame similar to indoasian /roma/ziva, modular surface box 8-way with cover plate and frame similar to indoasian /roma/ziva, modular surface box 12-way with cover plate and frame similar toindoasian /roma/ziva, pvc frls conduit pipe 20 mm, pvc frls conduit pipe 25 mm, pvc frls channel 32mm, pvc junction box 20mm 1-way, pvc junction box 20mm 2-way, pvc junction box 20mm 3-way, pvc junction box 20mm 4-way, pvc junction box 25mm 1-way, pvc junction box 25mm 2-way, pvc junction box 25mm 3-way, pvc junction box 25mm 4-way, pvc elbow 20 mm, pvc elbow 25 mm, pvc bend 20 mm, pvc bend 25 mm, pvc nail clamp 20 mm, pvc nail clamp 25 mm, pvc ceiling rose, 3 pin, 6 amps. to 32 amps. ratings , sp mcb, "c" curve, 10 ka breaking capacity, tp c-type mcb 32 amps., tpn c-type mcb 32 amps., tpn isolator 40 amps., tpn isolator 63 amps., tpn isolator 100 amps., tp mccb 16ka 100 amps., tp mccb 25ka 200 amps., tp mccb 50ka 400 amps., modular ac distribution box 20amps with plug top, mini modular sp mcb 20amps., 5 amps 3-pin plug top, 16amps 3-pin plug top, pvc insulated aluminium service wire twin core 6.0 sqmm, capacitor 2.5 mfd, procelain 500 a kit kat fuse unit open type, fuse wire 300amps, aluminum lugs 35 sqmm, aluminum lugs 50 sqmm, aluminum lugs 90 sqmm, aluminum lugs 120 sqmm, aluminum lugs 150 sqmm, aluminum lugs 185 sqmm, aluminum lugs 240 sqmm, aluminum lugs 300 sqmm, aluminum lugs 400 sqmm, 1-star ceiling fan of sizes 1200 sweep white in colour, exhaust fan 300 mm sweep metal body heavy duty, led street light fittings 50 w, led batten type tube light 20w, led retrofit tube light frame,20w, led tube lamp,20w, led bulb 9w, b22 3-star, led bulb 0.5 w, b22 (red and green), fr - electrical insulation tape, al. alloy/ cadmium plated iron screws, 35 mm, iron screws, 25 mm x 7 mm, iron screws, 35 mm x 7 mm, iron screws, 52 mm x 6 mm, nylon cable tie 300mm, ball bearing 6201, ball bearing 6202, wall grip, hylem sheet full 8x4 feet, wall fan 450 mm (metal body), wall fan 600 mm heavy duty (metal body)

corporations/Associations/Others

CTN :45698761 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For auction sale of miscellaneous iron steel scrap, vcb & other steel scrap,allu scrap ( aaac conductor),winding wire scrap,33 kv ct/pt unit various type/capacity without oil scrap,conductor scrap mix,16 kva ue dist. xmer( copper wound single phase without oil & stud),200 kva ue dist. xmer (alu. wound without oil & stud.),100 kva ue dist. xmer (alu. wound without oil & stud.)
 Loading, Please wait...

Connect us via What's Up