Get complete information related to latest Aaa Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aaa Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aaa Conductor Tenders.
Tender For estimate for erection of a 33kv interlinking line from 33kv gtn ht service 3kv gr cable feeder to 33/11kv ss ediganpally for providing of alternate supply to 33/11kv ss ediganpally by stringing 7.535kms of 100sqmm aaaconductor over now proposed 11mtrs pscc poles in operation section rajapur in operation sub division rajapur of mahabubnagar circle (general)
Tender For corrigendum : advance e-tenders are invited for material required for smooth running of t/wells under 91 no,25no,23no, 1 no out of 19 no and 41 no. scheme under 502 no deep t/well scheme of nawanshahar pwrmdc ltd.,sub division of distt. sbs nagar under bdc-1 division, ropar - bch make 110 amp duros freedom series 3 pole ac control contactor size -g cat no bch15mt-3-11, bch make spare magnetic coil size g,j,j,kcat no mc15kw, bch make spare magnetic coil size d,e,fcat no mc15fw, bch make ct operated overload relay range 37.6-60.0 amp cat no ct2 mc305ana3c, bch make ct operated overload relay range 56.4-90.0 amp cat no ct3mc305ana3c, bch make pneumatic timer time delay relay time range 0.05-60 sec cat no krtpn10-1 ac control, l&t make 3 pole power contactor type ml-3 size fr-2cat no ss90721, l&t make 3 pole power contactor type ml-4 70 amp size fr 3cat no ss90910, l&t make 3 pole power contactor type ml-6 size fr-3cat no ss90921, l&t make 3 pole power contactor type mnx-50 size fr-3 cat no cs97075, l&t make 3 pole du mccb breaking capacity 180 amp cat no cm980610000, l&t make spreader terminal for du250 3 pole mccb cat no st980530000 set of 6, l&t make spare contact kit type ml-3 cat no 5595309, l&t make spare contact kit type ml-4 cat no 5595311, l&t make spare contact kit type ml-6 cat no 5595313, l&t make spare contact kit type mnx 50 cat nocs94150, l&t make spare coil type ml3 cat no ss90545, l&t make spare coil type ml4 cat no ss91258, spare coil ml6 125amp, l&t make thermal overload relay type mn5 range 45-75 amp cat no ss9413700, l&t make thermal overload relay type mn5 range 66-110 amp cat no ss9413700k0, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 200 amp 415 volt with extension strip, kitkat 200 amp max, kitkat 500 amp max, copper thimble 100 amp, copper thimble 200 amp, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 25mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 16mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 10mm2, pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is 694 with latest ammendment size 19/16mm, al thimble, shunt capacitor with clamp l&t make 10 kvar, shunt capacitor with clamp l&t make 12.5 kvar, shunt capacitor with clamp l&t make 15 kvar, shunt capacitor with clamp l&t make 20 kvar, shunt capacitor with clamp l&t make 25 kvar, push button l&t red, yellow, green, blue, overload relay l&t 40-80 amp, overload relay l&t 20-60 amp, gic timer l&t 0.1sec to 10 hrs, gic timer l&t 30 sec to 120 sec, voltmeter 0-500 volt, ammeter 0-300 amp, ammeter 0-500 amp, ct voltmeter + ammeter combined, terminal block 100 amp 3 way l&t, pvc wire 7/64, control panel l&t make 50 hp, control panel l&t make 75 hp, boparai basp-0708a single phase preventer
Tender For corrigendum : advance e-tenders are invited for the material required for the smooth running of t/wells under 37 no twell scheme of tubewell construction sub division no. 4,shri anandpur sahib of block shri anandpur sahib distt. ropar - bch make 40 amp duros freedom series 3 pole ac control contactor size -g cat no ce15kn-3, bch make 40 amp duros freedom series 3 pole ac control contactor size -g cat no ce15kn-3 nb, bch make spare magnetic coil f series size g,j,j,kcat no mc15kw, bch make spare magnetic coil size d,e,fcat no mc15fw, bch make pneumatic timer time delay relay time range 0.05-30 sec cat no krtpn10-0 ac control, bch make pneumatic timer time delay relay time range 0.05-60 sec cat no krtpn10-1 ac control, l&t make 3 pole power contactor type ml-2 size fr-2cat no ss90701, l&t make 3 pole power contactor type ml-3 size fr-2cat no ss90721, l&t make 3 pole power contactor type ml-4 70 amp size fr 3cat no ss90910, l&t make 3 pole power contactor type mnx-32 size fr-2 cat no cs94111, l&t make 3 pole power contactor type mnx-40 size fr-2 cat no cs94190, l&t make 3 pole power contactor type mnx-50 size fr-3 cat no cs97075, l&t make 3 pole du mccb breaking capacity 100 amp cat no cm980610000, l&t make spreader terminal for du250 3 pole mccb cat no st980530000 set of 6, l&t make spare contact kit type ml-2 cat no 5595309, l&t make spare contact kit type ml-3 cat no 5595309, l&t make spare contact kit type ml-4 cat no 5595311, l&t make spare contact kit type mnx 32 cat nocs94128, l&t make spare contact kit type mnx 40 cat nocs94147, l&t make spare contact kit type mnx 50 cat nocs94150, l&t make spare coil type ml3 cat no ss90545, l&t make spare coil type ml4 cat no ss91258, l&t make thermal overload relay type mn5 range 45 75 amp cat no ss9413700j0, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 100 amp 415 volt without extension strip, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 100 amp 415 volt with extension strip, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 200 amp 415 volt with extension strip, kitkat 200 amp max, copper thimble 100 amp, copper thimble 200 amp, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 6 mm2, pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is 694 with latest ammendment size 7/16mm, pvc wire 7/64, shunt capacitor with clamp l&t make 8.33 kvar, shunt capacitor with clamp l&t make 10 kvar, shunt capacitor with clamp l&t make 12.5 kvar, shunt capacitor with clamp l&t make 15 kvar, shunt capacitor with clamp l&t make 20 kvar, main switch on/of l&t mark 100 amp 3pole, push button l&t red, yellow, green, blue, overload relay l&t30-50- amp, overload relay l&t 28-42 amp, gic timer l&t 0.1sec to 30 sec 12sdto, gic timer l&t 0.1 sec to 30 sec2b5dt5, voltmeter 0-500 volt, ammeter 0-300 amp, ammeter 0-500 amp, terminal block 100 amp 3 way l&t, boparai basp-0708a single phase preventer
Tender For corrigendum : advance e-tenders are invited for the material required for smooth running of t/wells under 08 no, 15 no. twell scheme under 502 no scheme and 05 no out of 19 no scheme of twell construction sub division no. 3 of block and distt. ropar - bch make 73 amp duros freedom series 3 pole ac control contactor size -g cat no ce15kn-3, l&t make 3 pole du mccb breaking capacity 180 amp cat no cm980610000, l&t make spreader terminal for du250 3 pole mccb cat no st980530000 set of 6, l&t make spare contact kit type ml-3 cat no 5595309, l&t make spare contact kit type ml-4 cat no 5595311, l&t make spare coil type ml3 cat no ss90545, l&t make spare coil type ml4 cat no ss91258, l&t make thermal overload relay type mn5 range 45-75 amp cat no ss9413700, kitkat 200 amp max, copper thimble 100 amp, copper thimble 200 amp, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 25mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 16mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 10mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 6mm2, pvc wire 7/64, pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is 694 with latest ammendment size 19/16mm, al thimble, shunt capacitor with clamp l&t make 10 kvar, shunt capacitor with clamp l&t make 12.5 kvar, shunt capacitor with clamp l&t make 15 kvar, push button l&t red, yellow, green, blue, overload relay l&t 30-50 amp, overload relay l&t 50-70 amp, overload relay l&t 40-80 amp, overload relay l&t 20-60 amp, gic timer l&t 0.1sec to 10 hrs, gic timer l&t 30 sec to 120 sec, voltmeter 0-500 volt, ammeter 0-200 amp, boparai basp-0708a single phase preventer, contactor mnx 95, spare kit mnx 95, ct voltmeter + ammeter combined, boparai overload relay 40-65 amp
Tender For corrigendum : advance e-tenders are invited for the material required for smooth running of t/wells under 52 no and 13 no out of 19 no twell scheme of garhshankar pwrmdc ltd., sub division of nurpur bedi block of distt. ropar - bch make 40 amp duros freedom series 3 pole ac control contactor size -g cat no ce15kn-3, bch make 40 amp duros freedom series 3 pole ac control contactor size -g cat no ce15kn-3 nb, bch make spare magnetic coil f series size g,j,j,kcat no mc15kw, bch make spare magnetic coil size d,e,fcat no mc15fw, bch make pneumatic timer time delay relay time range 0.05-30 sec cat no krtpn10-0 ac control, bch make pneumatic timer time delay relay time range 0.05-60 sec cat no krtpn10-1 ac control, l&t make 3 pole power contactor type ml-2 size fr-2cat no ss90701, l&t make 3 pole power contactor type ml-3 size fr-2cat no ss90721, l&t make 3 pole power contactor type ml-4 70 amp size fr 3cat no ss90910, l&t make 3 pole power contactor type mnx-32 size fr-2 cat no cs94111, l&t make 3 pole power contactor type mnx-40 size fr-2 cat no cs94190, l&t make 3 pole power contactor type mnx-50 size fr-3 cat no cs97075, l&t make 3 pole du mccb breaking capacity 100 amp cat no cm980610000, l&t make spreader terminal for du250 3 pole mccb cat no st980530000 set of 6, l&t make spare contact kit type ml-2 cat no 5595309, l&t make spare contact kit type ml-3 cat no 5595309, l&t make spare contact kit type ml-4 cat no 5595311, l&t make spare contact kit type mnx 32 cat nocs94128, l&t make spare contact kit type mnx 40 cat nocs94147, l&t make spare contact kit type mnx 50 cat nocs94150, l&t make spare coil type ml3 cat no ss90545, l&t make spare coil type ml4 cat no ss91258, l&t make thermal overload relay type mn5 range 45 75 amp cat no ss9413700j0, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 100 amp 415 volt with extension strip, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 200 amp 415 volt with extension strip, kitkat 200 amp max, copper thimble 100 amp, copper thimble 200 amp, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 4 mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 6 mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 10 mm2, pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is 694 with latest ammendment size 7/16mm, pvc wire 7/64, shunt capacitor with clamp l&t make 8.33 kvar, shunt capacitor with clamp l&t make 10 kvar, shunt capacitor with clamp l&t make 12.5 kvar, shunt capacitor with clamp l&t make 15 kvar, shunt capacitor with clamp l&t make 20 kvar, main switch on/of l&t mark 100 amp 3pole, push button l&t red, yellow, green, blue, overload relay l&t30-50- amp, overload relay l&t 28-42 amp, gic timer l&t 0.1sec to 10 hrs, gic timer l&t 0.1 sec to 120 sec, voltmeter 0-500 volt, ammeter 0-300 amp, ammeter 0-500 amp, terminal block 100 amp 3 way l&t, boparai basp-0708a single phase preventer
Tender For corrigendum : erection of an interlinking line between 33kv gurujakunta feederemanating from 132/33kv ss musthyala eht ss (at 33/11kv ssarjunpatla) in dhoolmitta section and 33kv narmetta feederemanating from 132/33kv ss palamakula (at 33/11kv ankshapur) innagunoor section which involves stringing of 33 kv line with 100sq.mm. aaaconductor for 6.2km over now proposed 11mtrs psccpoles in dhoolmitta section of cheriyal sub-division of husnabaddivision of siddipet circle under tandd improvements to originalworks (summer action plan-2026) (t-2531-17-05-23-04-001)
Tender For estimate for bifurcation of 11kv gattuipallapally feeder emanating from 33/11kv gattuipallapally substation which involves stringing of 3.5km 11kv scoh line with 55sq.mm aaaconductor over now proposed 9.1mtrs pscc poles along with erection of new 11kv feeder vcb at the same ss in talakondapally section of amangal sub-division of kandukur division of rajendranagar circle under t<(>&<)>d improvements to original works. - 63/dee/kkr
Tender For estimate for bifurcation of 11kv chowderpally feeder emanating from 33/11kv veljal substation which involves stringing of 3.8km 11kv scoh line with 55sq.mm aaaconductor over now proposed 9.1mtrs pscc poles along with erection of new 11kv feeder vcb at the same ss in talakondapally section of amangal sub-division of kandukur division of rajendranagar circle under t <(>&<)>d improvements to original works(summer action plan-2026) - 64/dee/kkr
Tender For estimate for providing of alternate source to 33/11kv gudur ss by stringing 1.5km of 33kv interlinking with 100sq.mm aaaconductor scoh line from 33kv kandukur feeder to 33kv raculoor feeder in kandukur section of mamidipally sub-division in kandukur division of rajendranagar circle under t<(>&<)>d improvement to original works.(summer action plan-2025). - 65/dee/kkr
Tender For estimate proposal for bifurcation of 11kv shubham feeder emanating from 33/11kv shadnagar town ss by erection of 1.7km new 11kv scoh line with 55sqmm aaaconductor on now proposed 11mts & 9.1mts pscc poles and existing m+6 towers of 33kv faroqnagar feeder duly providing 1no. additional 11kv vcb in 33/11kv shadnagar ss in operation shadnagar town section of shadnagar sub-division of shadnagar division of rajendranagar circle under t<(>&<)>d improvement works (summer action plan-2026)