Get complete information related to latest Aac Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aac Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aac Conductor Tenders.
Tender For replacement of existing acsr lynx panther conductor with acss rw lynx conductor on 132kv parawada koruprolu dc sc 44km line on turnkey basis in onm circle visakhapatnam
Tender For corrigendum : work of erection of balance work of 66kv s/c line on h frame from 66kv sadla s/s to 66kv umarda s/s with acsr panther conductor under kisan suryoday yojana.
Tender For replacement of old acsr panther conductor with new acsr panther conductor and associated jumpher s and all other associated work of 132 kv boner aligarh v line under etd i aligarh
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aacconductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For corrigendum : supply, erection, testing and commissioning of(i) 2nos 132kv bays (conversion from 2-ph to 3-ph) at 132kv ss bellampally (ii) 2nos 132kv metering bays (conversion from 2-ph to 3-ph) at new proposed 132/25kv rtss bellampally (iii) conversion of 132kv dc line from 2-ph to 3-ph (3km) from 132kv ss bellampally to 132/25 kv rtss bellampally (iv) modification of 2 nos 132kv bays at 220/132kv mandamarri ss (v) modification of 2 nos 132kv bays at 132kv bellampally ss (vi) strengthening of 132kv mandamarry-bellampally dc line (10km) by replacement of existing acsr panther conductor with htls conductor in mancherial district on turnkey basis
Tender For corrigendum : repairing of cable duct with cement concrete, fixing of barbed wire for extra protection of yard (with concertina wire) from monkey menance and replacement of panther conductor with acsr zebra in 132kv yard and replacement of non-functional high mast
Tender For replacement of existing 66 kv transmission line conductor acsr panther with high ampacity conductor tacsr 160 sqmm (single circuit) and erection of 66 kv dc tower due to low ground clearance of 66 kv vaghchhipa-silli ckt-i from apj college, dokmardi
Tender For corrigendum : supply of materials for maintenance work at 132kv sub station ghatampur under etd-ii kanpur - jaw assembly suitable for 36kv isolator, rating 2000a made of copper strip, aluminium strip, ms housing with spring nut and bolt as per sample., daw assembly suitable for 36kv isolatorrating 1250a made of copper strip, aluminium strip, ms housing with spring nut and bolt as per sample., terminal connector suitable for 36kv ct terminal rod and other end twin zebra conductor. made of lm-6 aluminium alloy with galv. nut & bolts. as per sample., 132kv special type isolator bi-matellic terminal connector (dropper/runthrough type) 50mm dia. and moose conductor as per sample., terminal connector suitable for 36kv ct terminal rod and other end twin panther conductor. made of lm-6 aluminium alloy with galv. nut & bolts. as per sample., terminal connector suitable for 36kv vcb one end terminal plate and other end twin zebra conductor made of aluminium alloy. with galv. nut & bolts. as per sample., terminal connector suitable for 36kv vcb one end terminal plate and other end twin panther conductor made of aluminium alloy. with galv. nut & bolts. as per sample without holes., terminal connector suitable for 36kv rama make isolator jaw plate size 80x80mm & 12mm thick and other twin panther conductor made of lm-6 aluminium alloy with gal. nut & bolts., multipurpose cleaner dc 2-26 spray type 400ml pack of standard make., 400 watt hpsv ballast suitable for high mast light fitting., termminal connector for 132kv pt suitable for panther conductor made of all alloy lm-06 completer with nut-bolt and washer as per sample., indication led ryb (24-110v) ac/dc standerd make suitable for control panle., silica gel 6-12mm granules of blue colour, sealed pack packing., terminal connector suitable for 36kv rama make isolator jaw plate size 80x80mm & 12mm thick and other twin zebra conductor made of lm-6 aluminium alloy with gal. nut & bolts., nut bolt with washer size 10x50 mm (gi), nut bolt with washer size 12x50 mm (gi), nut bolt with washer size 10x65 mm (gi), nut bolt with washer size 12x65 mm (gi), terminal connector lm-06 all. alloy suitable for 132kv ct heptacare make other end twin panther conductor with gi nut & bolt as per sample., terminal connector made of lm-6 alloy suitable for 33 kv g.nandy make solator jaw plate and other end twin panther conductor with galv. nut, bolts & washer as per sample., cb clamp 145 kv suitable for panther conductor with galv. nut & bolts., supply of female contact for 145kv rama make isolator as per sample., supply of male contact for 145kv rama make isolator as per sample.
Tender For supply of hydraulic compressor capacity - 100t with one set die suitable for aacconductor 240 sq. mm (hyd. compressor new improved with remote hand operated double action hyd. pump fitted with 2 m hose and pressure recording gauge ) as per annexure - a. [ warranty period: 30 months after the dateof delivery ] ]
Tender For loading, carriage and unloading of 18.8km panther conductor from 132kv s/s laxmipur to 132 kv s/s naugarh, 132kv s/s bansi and 132kv s/s itwa