Tender For corrigendum : : work of maintenance of various equipment’s at 33 kv controlpanel/ vcb/line isolator including retro fitting of damaged protection relay and maintenance & repair work of 11 kv vcb along with erathing of power t/f & control room & inreacting capcity of power t/f (at 33/11 kv quila s/s) etc. in different 33/11 kv s/s under 33 kv vertical, bareilly for system strengthening for providing uninterrupted 24*7 power supply under the head of (b.p. 2025-2026).
Tender For corrigendum : establishing 2x12.5 mva, 66/11kv sub-station at kalathmadu along with construction of proposed 66kv lilo line from the existing 66kv virajapete- ponnampete sc line on dc towers to proposed 66/11kv sub station at kalathmadu for a distance of 1.925km in virajpete taluk, kodagu district on partial turnkey basis including supply of all matching materials/equipments (excluding supply of 2x12.5mva 66/11kv power transformers and 11 kv switchgear) and erection (including civil works) of all materials/equipments, testing and commissioning - on load tap changer , control and relay panels, , circuit breakers, , 11kv mcvcbs & pcvcbs, , tower parts and all types of station structures with bolts, nuts and washers, , i beams & m.s channels, , lightning arrestors, , isolators, , insulators, , instrument transformers, , battery sets, , battery charger, , acsr conductors, , ground wire, , 11kv ug cable, , 1.1kv copper control cables & lt power cables, , capacitor bank, , hardware for insulator, conductor and ground wire:, , tension & suspension clamps and connectors., , accessories for conductor and ground wire:, , p.g clamps. m.s.c joints, pre-formed rods, repair sleeves, vibration damper etc., , c-type fire wedge connectors, , i) grounding materials (g.i flat, m.s flat etc.,), , il)grounding materials (c.i pipes), , ltac & dcdb panel, , 11kv termination & jointing kits, , class, , nitrogen injection fire protection, , system, , rigid tubular aluminium bus bars, aluminium clamps and connectors., , wave traps/line traps, , plcc equipment
Tender For corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset controlpanel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For mtc.of rws/pdf/15 fc/other panchayat/deposit fund schemes in north tripura 26-27/sh-providing, fixing in/c repair of electrical panel board comprising with starter main switch, motor protection device of panisagar block of dws sub-division, panisagar
Tender For corrigendum : repair/maint of earthing eqpts at otm bldgs lightning protection and repair maint of dg sets lt panel change over switch and lt cable at 33 su site 1a and 1b at afs jodhpur
Tender For supply of replacement of existing ms iron plate of driver cabin upper side of pbs of size 15 ft x 2 ft and thick 6 mm. , replacement of existing 02 x glass of crew cabin. , supply and fixing 1 x exhaust fan for kitchen room. , supply and fixing of 04 x iron net for air wind pipe of outer side. , supply and fixing 1 x ac dc panel. , supply and fixing of 26 x 5 amp socket. , supply and fixing of 36 x led tube light. , supply and fixing of 09 x switch board with 5 amp. , replacement of existing 06 x navigation light with glass protection. , replacement of existing rotary pump of pbs as per existing specification. , repair of leakage defect of pt pump of sbs. , replacement of existing 02 x iron battery box as per existing specification including all charges. , replacement of existing fuel tank of aux engine generator as per existing specification.
Tender For technical bid for supply of hvac operational spares , bearing (6206) size: od, 60 mm x id 50 mm ball bearing desig: 6001-z, ball bearing desig: 6307/2z c3 universal hvac/r controller, armoured 4 core x 6 sqmm xlpe copper cable. 1 sqmm frls multi stranded copper cable (single wire), 10 sqmm frls multi stranded copper cable (single wire) 4 sqmm frls multi stranded copper cable (single wire), fibre glass insulated copper wire for heater size: 6 sqmm, alkaline battery volt: 9vf sealed maintenance free (smf) lean-acid battery 7ah 12v, brush width: 3 inch for painting work. loctite 495 adhesive, kiwi drain cleaner heavy duty industrial safety gloves - cut-resistant (mechanical work), spray foam insulation (pfu) can qty: 750 ml wd 40 multipurpose spray size: 500 ml, green paint (bus green synthetic enamel black paint (synthetic enamel), ms flat bar size: 40 x 5 mm ms l- angle size: 25 x 25 x 5 mm, ms l- angle size: 40 x 40 x 5 mm metal primer (red oxide), black color spary paint 400 ml thread repair helicoil insert ss-m18 x 2.5mm x 1.5d, thread repair helicoil insert ss-m20 x 2.5mm x 1.5d thread repair helicoil, insert ss-m24 x 3mm x 1.5d thinner for oil-based paints, wire type buffing whee bench grinder wheel -heavy grade, dial test indicator (dti) gauge with flexible stem magnetic base stand, digital clamp meter capacity: 600a ac trms heavy duty exhaust fan, size: 9 inch backward curved fan with motor size: 355, mm dia ventilation fan for electrical panel sweep, dia: 12 cm induction motor fan, blade shaft size: 20 mm & blade dia: 130 mm, induction motor fan blade shaft size: 25 mm, & blade dia: 110 mm gi 6 mm x 25 mm bolt & nut with washer, anchor bolt with nut & washer size: 10 mm anchor bolt with nut &, washer size: 8 mm anchor fastner size: 10, mm for threaded rod gi self tapping screw, size: 3/4 inch (20 mm) head type: truss, pop screw size: 1 inch (25 mm) head type: flat (csk). ss self tapping screw size: 2 inch (50 mm), head type: hex din rail size: 35 x 7.5 mm, add on auxiliary contact block (1 no +1 nc) casing and capping size: 20mm (3/4 inch), casing and capping size: 50mm (2 inch) copper strip for electrical motor size: 25 x 3 mm, current transformer (for mfm/ammeter), ratio: 10/5a current transformer (for mfm/ammeter), ratio: 15/5a, current transformer (for mfm/ammeter), ratio: 20/5a current transformer (for mfm/ammeter), ratio: 30/5a, current transformer (for mfm/ammeter), ratio: 5/5a emergency stop switch, metal enclosure electrical junction box, size: 200mmx200mmx150mm, metal enclosure electrical junction box size:, 300mmx300mmx200mm three pole neutral (4p), 32 amps miniature circuit breaker (mcb) 4-way mcb metal enclosure, 2- module surface mounted pvc box. thermal overload relay, range: 14-23 amps electronic fan regulator, single module porcelain heater insulators or terminal. blocks, led indicator color: amber pin type lug size: 1.5 sqmm, pin type lug size: 2.5 sqmm pin type lug size: 4 sqmm, pin type lug size: 6 sqmm spade type lug size: 1.5 sqmm, spade type lug size: 2.5 sqmm metal flexible conduit size:19, motor protection circuit breaker (mpcb) range: 6.3-10 amps (rotary) motor protection circuit breaker (mpcb) inst trip rating: 2.5 amps (rotary), motor protection circuit breaker (mpcb) inst trip rating: 25 amps (rotary) motor protection circuit breaker (mpcb) inst trip rating: 50 amps (rotary), ms conduit size: 25 mm motor terminal block range: 10 hp/7.5 kw, motor terminal block range: 40 hp/30 kw thermal overload relay(olr) range: 20-33 amps, thermal overload relay(olr) range: 42-69 amps plug top 3 pin capacity: 5 amps, 4 pole power contactor capacity: mnx 12 4 pole power contactor capacity: mnx 18, 4 pole power contactor capacity: mnx 9 push button (illuminated) color: green, push button (illuminated) color: red plugable interface relay (4 c/o, 230 vac) with base, plugable interface relay (4 c/o, 24 vac) with base analog timer controller for split ac's, terminal block range: 0.2-2.5 sqmm,
Tender For repair maintenance of various e m services in various delhi govt offices under ae e emsd ii giri nagar kalkaji new delhi sh supply, installation, testing and commissioning of lightning arrester for surge protection l t panel earthing ups ac replacement of faulty led fittings
Tender For corrigendum : supply of excavation soft and loose soil not exceeding 1 point 5 metre deep and wide , returning filling in soilsspreading leveling watering and well ramming , removal of surplus soils not exceeding 50 mtr distance , m and l for sand filling with clean dry fine sand unwashed , s and l un reinforced pre cast with peak concrete cable protection , sitc cable heat shrink jointing kit of 11 kv grade 95 sq mm , sitc cable jointing kit of 11 kv heat shrink type 95 sq mm , s and fixing on ht pole danger notice plate for ht 11kv , sitc end joint for 1100 volt xlpe cable of size 95 to 120 sqmm , sitc heat shrinkable end joint for 1100 volt size150 to 240 sqmm , sitc heat shrinkable end joint for 1100 volt xlpe cable of size 300 to 400 sqmm , tubes light grade galvanised of size 80 mm , m and l for earthing complete with gi steel earth plate 600mm x 600mm x 6mm , m and l earthing complete with copper earth plate of size 600x600x3 point 15 mm , supply and fixing in repair lightning arrester single pole 11 kv 65 kilo amp , sitc of 11kv sf6 gas 4way rmu 630 amps , sitc of 11kv 630a switch sf6 disconnector outdoor panel , supply and installation and testing 11 kv outdoor type god , sitc of 200 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 160 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 100 kva level 03 transformer 11kv on ht and 433 volts on lt side , taking out of transformers 50 kva to 200 kva depositin in mes yeard , taking out old unsv ht ug cable of any size , dismantling air break gang operated switches , xlpe cable, working voltage from 3.3 kv up to and including 33 kv (v2) isi marked to is 7098 (part 2) (q2)