Web Analytics Made Easy - StatCounter

Ac Panel Scrap Tenders

Get complete information related to latest Ac Panel Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ac Panel Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ac Panel Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45741797 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For supply of spares components to earth leakage detector of anuvidyuth make. the set consists: 1. meter module (main card, insulation tester and panel meter), 2. channel module (channel card fittedwith accessories), 3. main module for add-on units, 4. channel card, 5. mains cards, 6. cable cards, 7. mother board, 8. panel meters, 9. transformer xr-273-3, 10. transformer xr-243-n1, 11. transformer xr-355, 12. terminal strips channel/mains, 13. display card, 14. test leads redx2+green, 15. frc connector for meter reading, 16. relay 4 change over, 17. multi turn pot 20k (mt), 18. reset switch mpu-2, 19. dc buzzer, 20. rotary switch, 21. euro9 connector 32 pin, 22. euro connector 48 pin and 23. 1m potentio meter for main module. firms offer: make/model: anu vidyut [ warranty period: 30 months after the date of delivery ] ]

Central Government / Public Sector

CTN :45516989 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : supply of 9040m26d81 spares of 23-k-101( khds rgc) - heater panel

State Government

CTN :45739217 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For supply of abb make ph sensor , abb make ph analyzer , abb make conductivity analyzer , conductivity sensor , annual spares kit , tubing kit exc pump tubes , power supply board panel mount ac

corporations/Associations/Others

CTN :45495960 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For corrigendum : repairing and overhauling of various types of fans and replacement of different types of defective electrical panel spares installed at different building of malda medical college and hospital, malda

Central Government/Public Sector

CTN :45726505 Due date: 20 Jul, 202620 Jul, 2026 45.00 Lacs
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep

Central Government/Public Sector

CTN :45738793 Due date: 21 Jul, 202621 Jul, 2026 NA
Tender For supply of electrical control & indication panel for miv , spares for electrical control & indication panel , spares for electrical control & indication panel for miv

Central Government / Public Sector

CTN :45737462 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For supply of set of spares for ckd make prv items suitable for aal make vcb 1. ckd prv with gauge , input & output bolts with washers, to suit aal vcb, ckd make asper part no. w-2000-10-w-m1. 2. ss input pipe with base plate for ckd prv suitable for aal vcb to m/s solutions automation part no: stap-3/8. 3. air gauge with metal adaptor, used at air tank in panel as per part no: g49d-6-10 p. make: ckd only. [ warranty period: 30 months after the date of delivery ] ]

CTN :45324747 Due date: 07 Jul, 202607 Jul, 2026 16.80 Lacs
Tender For corrigendum : supply of spares for dust suppression system for coal stock pile and conveyer system in chp, katpp, jhalawar - "solenoid valve50 nb, normally closed, 2in g/bsp pl, body moc- gorged brass,type_2/2-floating diagram, orifice(mm)-45. voltage -230v-240v,50hz, ,epoxy moulded coil with ip-65, coil class-h" , "solenoid coil with connector type anx voltage 230v w9,ed: 100%" , "solenoid valve 1/2 inch, normally close, cf8m,05-10 atm, ss316,operating operating voltage: 110v,50hz" , "solenoid valve 3/4 inch, normally close, 05-10 atm, ss316,operating operating voltage: 110v,50hz" , "solenoid valve 1 inch, normally close, 05-10 atm, ss316,operating operating voltage: 110v,50hz" , "coil for item sr no 3,4,5 (03 nos for each type)" , "pressure switch (adjustable-0 to 21 kg/cm2" , control transformer 1.5kva, primary :-380-400-415-440vac, sec.:-110vac , "control transformer 750va, primary :-380-400-415-440vac, sec.:-110vac" , "aux. contactor 4no+2nc ,110vac with 2nc addon blocks,110vac coil voltage" , "aux. contactor (o/e/n 58-24-c relay) 04no,12a, 24vdc" , aux. contactor with 3no+1nc,12a, 110vdc coil voltage , mpcb 2.2-3.2a, 50ka , power contractor 45a,tp,110vac coil voltage , power contractor 170a,tp,110vac coil , over load relay range:28-40a , over load relay range:85-135a , selector switch 4pole,2way,6a , auto/ manual selector switch 3p, 4way with off , on delay timer with 2no,2nc, coil voltage -110vac , 6" panel heavy duty exhaust fan,240vac , steel panel lock knob type ktisn - black and silver finish,22.5mm dia, round shape

CTN :45321471 Due date: 07 Jul, 202607 Jul, 2026 16.80 Lacs
Tender For corrigendum : supply of spares for dust suppression system for coal stock pile and conveyer system in chp, katpp, jhalawar. - solenoid valve , solenoid coil with connector , solenoid valve , solenoid valve , solenoid valve , coil for item sr no 3,4,5 , pressure switch , control transformer 1.5kva, primary :-380-400-415-440vac, sec.:-110vac , control transformer , solenoid valve , solenoid coil with connector , solenoid valve , solenoid valve , solenoid valve , coil for item sr no 3,4,5 , pressure switch , control transformer 1.5kva, primary :-380-400-415-440vac, sec.:-110vac , control transformer , auxiliary contactor , auxiliary contactor , aux. contactor with 3no+1nc, 12a, 110vdc coil voltage , mpcb ​​2.2-3.2a, 50ka , power contractor 45a, tp, 110vac coil voltage , power contractor 170a, tp, 110vac coil , over load relay range:28-40a , over load relay range:85-135a , selector switch 4pole, 2way, 6a , auto/manual selector switch 3p, 4way with off , on delay timer with 2no,2nc, coil voltage -110vac , 6" panel heavy duty exhaust fan, 240vac , steel panel lock knob type ktisn-black and silver finish, 22.5mm dia, round shape

CTN :44399633 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For corrigendum : procurement of medical equipment for mmch (package 1) - supply, installation,testing and commissioning of mri 3 tesla(along with associated works, accessories and allied items as specified), supply, installation,testing and commissioning of biplane dsa system with large flat panel detector with inbuilt angiography and intervention and stereotactic radiotherapy (along with associated works, accessories and allied items as specified), supply, installation,testing and commissioning of 256-slice dual energy spectral high end ct scanner (along with associated works, accessories and allied items as specified), supply, installation,testing and commissioning of 64 slice ct scan machine(along with associated works, accessories and allied items as specified), price schedulefor related services to be offered from outside and within the purchaser s country, comprehensive annual maintenance contract (camc) of the complete unit (mri 3 tesla) including spares and consumables for 5 years (after initial on-site warranty period), comprehensive annual maintenance contract (camc) of the complete unit (biplane dsa system with large flat panel detector with inbuilt angiography and intervention and stereotactic radiotherapy)including spares and consumables for 5 years (after initial on-site warranty period), comprehensive annual maintenance contract (camc) oft he complete unit (256-slice dual energy spectral high end ct scanner)including spares and consumables for 5 years (after initial on-sitewarranty period), comprehensive annual maintenance contract (camc) of the complete unit (64 slice ct scan machine)including spares and consumables for 5 years (after initial on-site warranty period)
 Loading, Please wait...

Connect us via What's Up