Web Analytics Made Easy - StatCounter

Ac Dc Clamp Tenders

Get complete information related to latest Ac Dc Clamp Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ac Dc Clamp Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ac Dc Clamp Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45719686 Due date: 13 Jul, 202613 Jul, 2026 44.90 Lacs
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl

Central Government/Public Sector

CTN :45713835 Due date: 18 Jul, 202618 Jul, 2026 30.00 Lacs
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc

Central Government/Public Sector

CTN :45728977 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of instrumentation junction box, cable glands, plugs -lot-2 for numaligarh refinery expansion project

CTN :45255749 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For corrigendum : tender for supply of hea igniter system -hea igniter exciter box , hea igniter cable assembly , hea igniter retractor assembly , hea igniter flexible spark rod assembly , hea igniter spark rod tip , hea igniter guide pipe assembly , local panel , control panel , common manual isolation valve instrument air , air set and air manual isolation valve instrument air with copper tube and fitting from burner front , cooling air one and half inch hard rubber high temperature hose 1500 mm with end clamp , erection materials mounting hardware and other supporting materials cables glands cable lugs

CTN :45478137 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For corrigendum : items - computer and servises and otheres, mcb (miniature circuit breaker), acb (3200a/4000a ), acb (air circuit breaker), allen key set, amf relay, ammeter, annunciation system, anti-corrosion spray, arc flash suit, arc flash suit (ht/lt panel ), auxiliary contacts, avr (automatic voltage regulator), battery charger, blower/air blower, breather assembly, bus coupler acb, busbar insulators, busbar supports, cable glands, cable glands, cable lugs, cable ties, cable ties, changeover switch, clamp meter, clamp meter, combination pliers, consumables, contact cleaner spray, contactor, continuity tester, control cable, control fuses, control relay, control wires, cooling fan, copper busbar, crimping tool, ct (current transformer), current transformer (ct), dg set synchronization panel (3 750 kva), digital multimeter, digital multimeter, discharge rod, earth fault relay, earth switch, earth tester, earthing rod, electrical contact cleaner, electrical gloves (11 kv rating), electrical safety gloves, emergency stop switch, energy meter, engine control module, face shield, ferrules, ferrules, flexible wire, frequency meter, fuse fuse base, heat shrink sleeves, heat shrink tubes, hrc fuse, hrc fuses, ht protection relay, indicator lamps (r/y/b), infrared thermometer / thermal camera, insulated screwdriver, insulation tape, isolator switch, lightning arrester, load sharing module, lockout-tagout (loto) kit, loto kit, lt pcc/mdb panel, lubricant spray ( ), lugs, maintenance tools, mccb, mccb (molded case circuit breaker), megger (insulation tester), megger 5 kv, microfiber cloth, motorized mechanism, multifunction meter, multifunction meter, nose pliers, numerical protection relay, oti (oil temperature indicator), over current relay, overload relay (olr), phase sequence meter, phase sequence tester, plc module, power analyzer, power cable, power factor meter, protection & metering, pt/vt (potential transformer), push buttons (start/stop), pvc insulation tape, reverse power relay, rust remover, safety equipment, safety goggles, safety helmet, safety helmet, safety shoes, safety shoes, screwdriver set, secondary injection test kit, selector switch, shunt trip coil, side cutter, silica gel, smps (power supply), soft brush, spanner set, speed governor module, spiral wrapping, spring charging motor, starting relay, synchronizing relay, terminal blocks, thermal camera, thermostat, timer relay, torque wrench, transformer buchholz relay, transformer oil, under/over frequency relay, under/over voltage relay, uv coil, vacuum cleaner, vcb (vacuum circuit breaker), voltage tester, voltmeter, wire markers, wire stripper, wti (winding temperature indicator), , , , comprehensive maintenance of substation, transformer, panels, synchronization panel a including all consumables, accessories, minor & majour spares, cleaning materials, testing instruments, preventive maintenance and breakdown maintenance complete., annual maintenance of substation, transformer, panels, synchronization panel a including all consumables, accessories, minor spares, cleaning materials, testing instruments, preventive maintenance and breakdown maintenance complete.

CTN :45609584 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For corrigendum : supply of supply of lcs with ammeter , supply of soot blower panel , supply of cable glands and plugs , supply of pdb

Central Government/Public Sector

CTN :45722323 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For supply of cable glands for ph 1,cable lugs for ph 1,cable glands for ph 2,cable lugs for ph 2,spare cable glands for ph 1 and ph 2,spare cable lugs for ph 1 and ph 2

State Government

CTN :45464849 Due date: 08 Jul, 202608 Jul, 2026 2.37 Lacs
Tender For corrigendum : supply of digital tong tester, multimeter, clampmeter, mini ac/dc clampmeter, telescopic earth rod, storage water heater, drilling machine, rubber mat, etc.,required for shiva power house, kpcl, malavalli-571 437

Central Government/Public Sector

CTN :45252215 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For corrigendum : supply of enclosures complying with nema 4x standard , m20 type cable glands fixed in the bottom of the boxes, 60 boxex with 6 cable glands and 60 boxes with 2 cable glands , plane abs or plastic mounting plate fixed in all the boxes , soft copy of serial numbers of the enclosure , charges for transportation of consignment to rmc chennai

Central Government/Public Sector

CTN :45382837 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
 Loading, Please wait...