Web Analytics Made Easy - StatCounter

Ac Ducting Scrap Tenders

Get complete information related to latest Ac Ducting Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ac Ducting Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ac Ducting Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45527664 Due date: 14 Jul, 202614 Jul, 2026 NA
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - thermal power plant; work of cleaning maintenance and overhauling of various lt mcc generator phase and neutral links generator bus duct excitation transformer lavt and..

Central Government/Public Sector

CTN :45714895 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For special repairs to lt panels and connected items at pyro, pinaka, nag mixture building, magazine area and ap building in hemrl, pune - taking out old serviceable/unserviceable lt panel/capacitor panel of any description or capacity keeping aside in safe custody for schedule of credit complete all as specified and directed, supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 nos, (c) mccb 4p, 125 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 200/5 - 04 nos, (e) control mcb c curve, sp, 6 to 32a, 10ka, c curve - 02 nos, (f) led phase indicator (r,y & b) - 01 set. (pyro sub stn), supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (c) mccb 4p, 315 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) mccb 4p, 250 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 nos (e) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 800/5 - 04 nos, (e) con

Central Government And Public Sector

CTN :45704062 Due date: 06 Jul, 202606 Jul, 2026 5.16 Lacs
Tender For supply of modernization of distribution infra 2x400 kva substation companybagh b b -dismantling and refurbishing of electrical distribution system , itc of existing load bank with static meter , itc of existing load bank , trimming and pruning of four trees , transportation of one dismantled lt panel darbhanga to mzp , removing of old faulty outlived mv panel , provision of structural iron channels mounting framework for the lt panel , re-furbishment of existing mv panel , brickwork for minor structural alterations near the lt panel support base , straight through joint 185 , straight through joint 50 , removing and relaying of existing cement interlocking bricks , laying of 1.1 kv grade of 35 sqmm to 185 sqmm direct in ground , dressing of cables , finishing of the lt bus bar box , 20w surface-mounted led tube light , a. horizontal type tpn db 8 way with double door , b. horizontal type tpn db 8 way single door , a. vertical type, 415 v, tpn db 8 way double door , dressing of dbs , a. single pole mcb 6 to 32 a , b. four pole isolator 63 a , c. four pole isolator 40 a , d. double pole isolator 40 a , e. tp mcb 63 a , f. 125 a tp mccb 16 ka , 3 pole mccb of 250a, 25 ka , itc of existing lt bus bar box , sitc wall mounted heavy-duty air circulators fans of 600mm metal blades , supplying and fixing of 5mm thick m.s.chequered plates , fixing of ms stand of pac outdoor unit , providing double coat spray painting , sign writting numbering on all panel proper marking of its connectivity , a. wiring for light point group-a , a. copper conductor, single core cable 2 x 1.5 sq. mm , a. medium class pvc conduit 20 mm , shifting re- installation of submersible pump staters , making opening of wall to suit the size of 380 mm sweep exhaust fan , supplying fixing of exhaust fan of 380 mm sweep heavy duty , a. blanking plate , b. 5 pin 15 a socket , c. 15 16 a piano type switch , d. 5 6 a piano type switch , e. 3 pin 5 6 a socket outlet , f. 3 pin 15 a top , g. wall fan , h. down rod for ceiling fan installation 3 ft length hook , a. 100 watt flood light , b. 24 w led rimless surface panel light , sitc of 100 a 3 phase neutral copper bus bar in sheet steel enclosure , dressing of existing distribution system of type ii staff qtr , itc of 100 a 3 phase neutral bus bar with 100 a mccb in sheet steel enclosure , supplying fixing of double pole spn mcb 32 a in the sheet steel enclosure , s l 2 1.5 sqmm copper conductor , removing the faulty lt cable of size 3.5 core 240 sq.mm , ms clamp on four pole structure for fixing the ht cable , extracting of spare main ht cable 11 kv 95 sq mm size from the soil , extracting of faulty spare ht cable 95 sq mm from the duct manual labour , fastners nut bolt, al lugs, socket, cu lugs socket, washers, screw, pvc clips , acrylic sheet of 2 mm thickness , hrc fuse of 200 a //bid details 2 / 49

CTN :45048307 Due date: 31 Jul, 202631 Jul, 2026 NA
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp

State Government

CTN :45654948 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For supply of silica gel indicating type (blue) for ht / lt bus duct, power and service transformers breather as moisture absorbent at stps.

State Government

CTN :45510332 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For supply of silica gel indicating type (blue) for ht / lt bus duct, power and service transformers breather as moisture absorbent at stps

CTN :45358277 Due date: 22 Jun, 202622 Jun, 2026 51.00 Lacs
Tender For routine/breakdown and capital mtc work of l.t. motors, valve actuators, l.t. switchgear, bus-duct and d.c. system and cabling work at stps stage- i, ii, iii and iv.

CTN :45357141 Due date: 22 Jun, 202622 Jun, 2026 51.00 Lacs
Tender For routine/breakdown and capital maintenance work of l.t. motors, valve actuators, l.t. switchgear, bus-duct and d.c. system and cabling work at stps stage- i, ii,iii and iv against tn-3216 (elect.).

State Government

CTN :45267006 Due date: 30 May, 202630 May, 2026 NA
Tender For supply of silica gel indicating type (blue) for ht / lt bus duct, power and service transformers breather as moisture absorbent at stps

State Government

CTN :45143871 Due date: 19 May, 202619 May, 2026 NA
Tender For supply of silica gel indicating type (blue) for ht / lt bus duct, power and service transformers breather as moisture absorbent at stps.
 Loading, Please wait...

Connect us via What's Up