Get complete information related to latest Ac Plant Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ac Plant Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ac Plant Spares Tenders.
Tender For repair/maint of air cooled acplants, chiller, condenser pump, hot water boiler, ahu, water colled acplants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled acplants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled acplants(once in a three months), material and labour for descaling of complete condenser units for central/ package type acplants of condenser unit of water cooled acplantacplant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo acplant and new acplant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the acplants at different locations complete all as specified and as directed. location :- old and new acplant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new acplant, old acplant , 3 ac igloo ac and akash acplants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash acplants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash acplants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash acplants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new acplant , old acplant and air coole
Tender For supply of supply of package type air conditioning plants of 16.5 ton capacity at akashvani rampur. equipment consisting compressor unit, air cooled condenser, cooling coil, blowers, refrigerant piping system , modification in existing plenum chamber and shall be connected to existing ducting system and will be modified to accommodate the unit. minor repair job shall be done by the firm, if required. , return air chambers at akashvani rampur , switch board and wiring of equipment at akashvani rampur , electrical earthing at akashvani rampur , itc of acplant includes, dismantling of old acplants, misc. jobs required for installation of acplants and provision of indicators for filter clogging and condenser clogging at akashvani rampur , supply of package type air conditioning plant of 16.5 ton capacity at akashvani kanpur. equipment consisting compressor unit, air cooled condenser, cooling coil, blowers, refrigerant piping system , return air chambers at akashvani kanpur , switch board and wiring of equipment at akashvani kanpur , electrical earthing at akashvani kanpur , itc of acplant includes, dismantling of old acplants, misc. jobs required for installation of acplants and provision of indicators for filter clogging and condenser clogging at akashvani kanpur * /bid number : gem/2026/b/7640468 + /dated: 22-06-2026 ' ' / bid document 1 / 24
Tender For corrigendum : comprehensive maint of central acplant air handling unit repair of cooling tower pumps body parts pipe line and ducting and comprehensive maint of diesel generator set installed at cgda and centrad external lighting and other miscellaneous e and m work at cgda hq and cent
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - thermal power plant; work of cleaning and replacing of nozzles end plugs gi clamps etc of natural draft cooling tower and opening and closing of cw duct air vent manhol..
Tender For repair and chemical descaling of cooling towers 03 nos. 275 tr each of flow tech make induced draft of size 3 mtrs x 3 mtrs for chiller plant of capacity 225 tr installed at the roof top of the air conditioning plant along with strainers at govt.