Get complete information related to latest Ac Power Supply Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ac Power Supply Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ac Power Supply Tenders.
Tender For regular operation and maintenance of street lights (with material) at all industrial areas under riico ranpur kota(for 2 years) - regular operation and maintenance of high mast light in ranpur , kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register shall be maintained at riico/association office and complaint lodged must be attended by contractor within 24 hours. the person deputed by contractor shall attend the riico/association office daily and comply the instructions and attend complaints regularly. iii contractor will have to employ trained and qualified electricians for the work. iv corporation shall not be responsible for any kind of accident during execution of work. v contractor will be responsible for safety and security of fixtures and all concerned materials. vi contractor will be responsible for arrangement of all t&p required for the work vii cost of all labour and material like lamp / balllast wire etc. will be born by contractor. all material required for the work shall not be below the category-ii of concerned bsr item. contractor has to repair and maintenance of fixture with material in all cases like short circuit, phase to phase of jvvnl line etc. viii no extra payment will be made for fixing/removal of extra/existing fixture in the industrial area. ix contractor will be responsible for timely collection and deposition of electric bills of areas in each month. in case of delay in payment and jvvnl impose surcharge for delay payment the same will be recovered from the running bill fo the contractor. payment of electricity bill will be made by riico. x contractor will be responsible for rebate of timer provided by jvvnl. hence contractor will maintain the on/off system by timer properly. in case no rebate is provided by jvvnl due to failure of timer then rebate will be deducted from contractor payment. xi contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. in case of any theft is found suitable penalty will be imposed on the contractor. xii contractor will maintain cubical panel board and assessories fitted in it. in case of any fault repair/replace of material will be done by the contractor at his own cost. no extra payment will be made on behalf of material. xiii contractor has to keep ready total fixtures. in case of fault of fixture a penalty of rs.100/- per fixture per day will be imposed on the contractor., regular operation and maintenance of street light fixtures hpsv/ hpmv (70w/150w) in ranpur, kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register sh
Tender For bench top pressure gauge calibrator with accessories- pressure calibration system, maximum no. of pressure module simultaneously, working medium, mode, sensor module range 1, accuracy of sensor module range 1, sensor module range 2, accuracy of sensor module range 2, precision, uncertainty of sensor module range 1, uncertainty of sensor module range 2, measurement modules, control mode, control precision, lowest controllable pressure limit, pressure indication & display system, over pressure protection, leak test & switch test, jog wheel, system mode, valve driver, vacuum pump, contamination prevention system, pressure display units, dc voltage range, dcv resolution, dcv uncertainty, dc current range, dci resolution, dci uncertainty, loop compliance voltage, hart mode, automatic hart detection, hart selectable resistor, write protection, hart commands, remote communication interface hardware, acpowersupply, operating temperature range, relative humidity, ingress protection, plumbing lines, fittings and adaptors, warranty, calibration certificatte, test port max. pressure limit, reference port max. pressure limit, vent port max. pressure limit, test port, supply port max pressure limit, liquid or particle filter
Tender For supply and testing of digital vhf 25 watt radio with plain mic standard accessories, powersupply unit cum battery charger (13.5v/15a) 12v/100ah vrla battery with i-lead connectors lmr 400 co-axial cable with end connectors(30 meter) high gain base antenna with clamps 1.25 pipe pole mast with clamping and stay wire arrangements base station units and built in aes 256 bit encrption (open standred for interoperability) as per rdso spec no. rdso/spn/tc/107/2018 rev. 0.0 amd 1 or latest simlar to motrolaxir m8668i aes 256 eicryption. note - 1. type of battery should be as per requirements of para 3.0 of rdso specification. note-2. the oems overall warranty period should be for 5 years from the date of supply forthe radio set and minimum 1 year for the battery, battery charger and antenna. note-3. the bidders shall submit a model and make of the 25 wats vhf set along with successful poc trail certificate issued by rdsoand the same poc certificate, mtcte certified and wpc certification shall be uploaded along with the bid. inspection by rites. make/brand- rdso poc approved make/mode, accepted make/brand: motorola, kenwood or better. [ warranty period: 30 months after the date of delivery ] ]
Tender For chop saw metal cutting machine of size 14 inch, 230 v 50 hz acpowersupply. similar to bosch model no gco200 or hitachi model no.cc14std. [ warranty period: 30 months after the date of delivery ] ]
Tender For supplying, installation, testing and commissioning of equipments for electrical measurement, electrical workshop, electrical machine & power system laboratory at ttaadc polytechnic institute, khumulwng, west tripura for the project "improvement of infrastructure in ttaadc polytechnic institute, khumulwng, west tripura, district under higher education department” under the nec scheme. (2nd call) - supplying, installation, testing and commissioning of electrical measurement, electrical workshop, electrical machine & power system laboratory equipments/machineries of electrical engineering department at ttaadc polytechnic institute, khumulwng, west tripura under the nec scheme "improvement of infrastructure in ttaadc polytechnic institute, khumulwng, west tripura, district under higher education department." (2nd call), kelvin double bridge trainer kitthe instrument should have following features : easy illustration of kelvins bridge digital display (dpm) for null detection online product tutorialthe instrument should have following technical specifications :dc powersupply : +5vknown resistance : r1=100k , 20k , 10k r3=1k , 200 , 100 dpm : 2vdimensions (mm) : 240 w x 345 d x 110 hunknown resistance : 0.3 , 0.4 , 0.8 mains supply : 230 v 10%, 50 hz, whetstone bridge trainer kitthe instrument should have following features :sample : constantan, nichromeprovided with dc powersupply compact designeasy to operatethe instrument should have following technical specifications:dc powersupply:5vgalvanometerdeflection:30 - 0 30resistance:80 unknown resistance type: variablerange:0 - 10k wire samples: -constantan: 1mnichrome:1mfuse:500mamains supply: 90 - 275v, 50hzdimensions (mm):w 345 x d 240 x h 110, experimentation with de sautys and schearing bridgethe instrument should have following features: - a complete set up with all necessary accessories inbuilt 1 khz sine wave generator with variable amplitude null detector with dpmtechnical specification: -sine wave generatorfrequency range:1khz 10%amplitude control output: up to 15vppfuse:500 ma, s/bdpm:200 mvunknown capacitor:0.1 f, 0.22 f, 0.47 fmains supply:230v ac, 10%, 50hzdimension (mm):w 345 x d 240 x h 110, experimentation with maxwells bridgethe instrument should have following features : illustration of both maxwells inductance bridge and maxwells inductance-capacitance bridge on a single board inbuilt 1 khz sine wave generator with variable amplitude null detector with dpmthe instrument should have following technical specifications :mains supply : 230 v 10%, 50 hzdc powersupply : +12v, -12vsine wave generatorfixed frequency : 1khz 5%amplitude control range : upto 20vppunknown inductors : 10 mh, 20mh, 30 mh, 56 h, 24 h, 12 hdpm : 200mvunknown internal resistance : 470w, 10 , 20 , 30dimensions (mm) : w 240 x d 345 x h 110, measurement of three phase active & reactive power with single phase wattmeter technical specifications:analog meters: analog voltmeter, range : 300v analog ammeter, range : 2a analog wattmeter power supplies: operated on mains power 415v, 50hz +10%components are mounted on the panels are: capacitive load inbuilt inductive load inbuilt resistive load (external)salient features: three phase power light indicator for mains. front panel built with high class insulated bakelite sheet with sticker well printed circuits and symbols. mcb for short circuit protection connections are brought out through 4mm colored safety sockets. patch cords 4mm. the trainer is housed in metal cabinet. size of the trainer set 36 x 24 , power & power factor measurement by ct & pt in three phase circuittechnical specifications:power supplies: acpowersupply 0-415v at 4a operated on mains power 415v, 50hz +10%digital meters: digital voltmeter digital ammeter , digital wattmeter (analog), digital power factor meter components are mounted on the panels are: 3 phase capacitive load (inbuilt) 3phase resistive load (external) 3phase inductive load (external) emergency stop
Tender For corrigendum : special repair for replacement of old hpsv hpmv cfl street light with new led street light fittings and allied work in certain unit at mil stn jaisalmer
Tender For corrigendum : supply of kyocera photocopier machine powersupply card , canon photocopier machine acpowersupply card , canon photocopier machine dc controller card , canon photocopier machine high voltage powersupply card , smps hp pro tower for desktop
Tender For supply of 45w led street light fitting, color-white cool day light (6500-7500k), 4000 lumens, 220- 240 volt ac, 50 hz suitable for 230 volt 50 hz acpowersupply, ip 66 & above rated, beam angle-120 degree, minimum 120 lumens/watt, bracket housing inner dia must be required 60 mm. out- door application type with die-cast aluminum body with suitable drivers, surge protectors, clamps and all connected materials for fixing to above conforming to wrspecification no. wr/ccg/ specification/p/ 001 (rev.01)-2018. note: minimum 5 years on site warranty require from the date of acceptance of material. make; philips, wipro, jaquar, havells, crompton, polycab ,bajaj, only [ warranty period: 60 months after the date of delivery ] ]