Get complete information related to latest Ac Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ac Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ac Scrap Tenders.
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - pw-95g (tmd-6) annual maintenance contract of voltas make chiller plant and other related auxiliaries of air conditioning system installed at 500mw unit no-6 of ukai tps; as per schedule b and ..
Tender For auction sale of scrap alternator/ starter motor,scrapac compressor,scrap motor (blower+radiator fan+wiper),radiator and condenser scrap with attached al pipe,e-waste with speaker,scrap - tyres with rim,scrap - tube,scrap nut & bolt,scrap - defaced engine (4w-steel 80%),scrap - defaced engine (cv),mix steel with chassis scrap,scrap steering column,steering rack,front shocker with spring & rear shockers,empty catcon,bale body (bundle),doors assembly and trunk lid assembly,scrap - plastic (bumper + black pp+hd+dashboard+acralic),scrap - rubber(pcb_ catagory)
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For procurement of spares for cooling towers (make-paharpur cooling towers limited) installed for cooling of circulating water for air compressor system and air conditioning system at u 7 and 8, ssctps, rvun, suratgarh - requirement of spares for cooling towers installed for cooling of circulating water for air compressor system in ahp area, model no. 6405m, grdr 20t rt-2.71:1 68-4592-1, fan assy 60in h-3-6 p85- (pcu-2/c) 3118-2, fill pack pc-47 p83-3128-1, d/s 6q cli 460 gb1.1/8 mb 38, spray nozzle p86-1082-3pp, elim pack stack pc-47 96-2034-17, branch pipe 50nb p85-1142-6, d/s coupling 6q with nbm insert gear side(gear shaft hole dia: 35 mm), d/s coupling 6q with nbm insert motor side(motor shaft hole dia: 48 mm), louvers, requirement of spares for cooling towers installed for cooling of circulating water of ac system in ca area, model no. 22103 for item s. no. 2.01-2.06 and model no. 3861 for item s. no. 2.07-2.10, fill sht mx75-8.1 lev p89- 4049-7, fill sht mx75-8.1 lev p89- 4049-8, fan assy 96in h-3-6, grdr 20t cc2, kit d/s 6q i nbm insert (rubber bush withhardware for drive shaft coupling), s.t. nozzle 68 3738-0xx pp, fill sht mx75-8.1 leh 86-4500-3, fill sht mx75-8.1 leh 86-4500-4, brg hsg assy sr118se, fan assy 54in h-3-6, requirement of stitching material for repair of damaged of frp structure of cooling towers, frp stiching material (fibre resin, fibre matstraid, mekp, cobalt, brush, chalk powder etc.)
Tender For annual repair work for replacement of old air conditioner by vrv/vrf air conditioning system in hon,ble minister chamber and officers chamber at vidhan sabha bhawan bhopal
Tender For auction sale of miscellaneous iron scrap,m.s. scrap (mild steel scrap),vir/pvc wire (allu),all allu. alloy. conductor,acsr scrap (normal siz),pvc armoured service cable scrap,gi scrap
Tender For auction sale of 16 kva single phase distribution transformers,capacitor 11kv scrap,aluminum wire-transformer winding scrap,iron steel scrap - list attached,conductor acsr scrap, insulated wire/cable aluminum scrap,plastic scrap,energy meter scrap/defective (including big body three phase 40-200 amp meter)
Tender For re-furbishing of branch office building (own premises) including civil works, painting and external repair works, interior works modular furniture, chairs, electrical installation, data & telephone cabling, supply, installation, testing and commissioning of air conditioning system, and fire alarm systems at mahabubnagar under hyderabad division , telangana state.