Get complete information related to latest Ac Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ac Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ac Scrap Tenders.
Tender For bid to ras corrigendum : supply of mechanical engineering equipments - models and charts , drawing equipments and instruments , models for projection and demonstration , combined shear force and bending moment apparatus , heat pump , separating and throttling calorimeter , indicator unit , green sand moulding up, casting up and patterns , hot forging equipment , punching blanking press , screw pitch gauge , working models of surface condenser , refrigerant leak detector , air conditioning test rig , air conditioning unit , sling psychrometer , natural convection apparatus or test rig , forced convection apparatus or test rig , thermal conductivity apparatus , stefan boltzmann up , thermal conductivity apparatus for composite wall , advanced casting equipments and tools , 3d printer , bicycle free wheel sprocket mechanism, geneva mechanism, ackermans steering gear mechanism and foot operated air pump mechanism , different types of cams, follower sand cam follower arrangements , various belt drives, chain and sprocket , various types of brake assemblies , vehicle tyre balancing machine , proximity sensor kit , temperature transducer kit , pressure transducer kit , flow sensor kit , thermistor , thermocouple , stepper motor control trainer , hydraulic motor trainer , cut sections of pumps, actuators, valves and accessories used in hydraulic systems , working models of pumps, actuators, valves and accessories used in hydraulic systems , oil hydraulic trainer , advanced electro hydraulic and electro pneumatic hardware systems , out put devices , thermal actuators , magnetic actuators , open and closed loop control system kit , pid controller test bench , cro 150mhz and 100mhz and 70mhz and 50mhz , rs485 i o module , ethernet i o module , pneumatic trainer , hydraulic trainer , thermal conductivity apparatus, metal bar, electric heater, thermocouple , experimental set up for thermal conductivity of liquid , experimental set up for thermal conductivity of insulating material , composite wall apparatus , critical radius of insulating materials apparatus. , experimental up to for testing effectiveness of metallic fin pin fin apparatus , a metallic tube of diameter d 45mm and length l 450mm with a electrical heater coil along the axis of the tube , stefan boltzmanns apparatus , emissivity apparatus , critical heat flux up , batteries and fuel cells , hydrometer , capillary tube , red wood viscometer , beaker , pipette , electronic balance
Tender For supply of air conditioning works at canara bank regional office pune i c c - vrf ac system out door unit 22 hp , vrf ac system out door unit 18 hp , cassette air conditioner indoor unit 0.6 tr , cassette air conditioner indoor unit 1.0 tr , cassette air conditioner indoor unit 1.6 tr , cassette air conditioner indoor unit 1.8 tr , cassette air conditioner indoor unit 2.0 tr , cassette air conditioner indoor unit 3.0 tr , wireless remote , centralised touch screen remote controller station , indoor refnets y joint , outdoor refnets y joint , lspi of vrf outdoor 22 hp , lspi of vrf outdoor 18 hp , lspi of indoor unit 0.6 tr , lspi of indoor unit 1.0 tr , lspi of indoor unit 1.6 tr , lspi of indoor unit 1.8 tr , lspi of indoor unit 2.0 tr , lspi of indoor unit 3.0 tr , itc of centralised touch screen remote controller , itc of indoor refnets y joint , itc of outdoor refnets y joint , gas topping pressure testing vaccuming , refrigerent pipng hard copper , power cable , pvc drain pipe 32 mm , pvc drain pipe 25 mm , refrigerent pipng soft copper , ms frame work as per boq , associated civil work , gi cable tray , gi cable cover for gi cable tray , sitc of 400cfm inline fan , gi sheet work , nitrile thermal insulation , linear grille diffuser , supply canvas , supply of 1500cfm inline fan , itc of 1500cfm inline fan , gi rectangular ducting , gi ducting , flexible duct connections , exhaust air outlet connections , vcd damper , timer arrangement , pvc pipe , disc valve
Tender For supply of air conditionining installation work at sonari branch d d - 1.5 tr capacity hi wall mounting 5-star rated inverter split ac , 2.0 tr cassette type split air conditioners inverter model 5 star , installation charges of the split type ac , installation charges of the 2.0 tr cassette split ac , reprigerent pipe for 2.0 tr cassette ac , reprigerent pipe for 1.5 split ac , 4 kva stabilizer for split ac , 5 kva stabilizer fo cassette ac , removing of existing air conditioning unit.
Tender For tender for supply of supply installation and commissioning of vrv or vrf air conditioning system : : - supply of vrv type multi unit ac system complete with indoor and outdoor units with individual controller for cooling application 14hp cooling ods unit , supply of vrv modular type indoor units comprising of all accessories. the indoor units shall be suitable to work on cooling mode. the indoor units shall be suitable for operation of 220v , 1 ph ac power supply with capacity 2tr cassette indoor unit with wireless remote , supply of vrv modular type indoor units comprising of all accessories. the indoor units shall be suitable to work on cooling mode. the indoor units shall be suitable for operation of 220v , 1-ph ac power supply with capacity 4tr cassette indoor unit with wireless remote , installation testing and commissioning of vrv system including copper piping , ducting with canvas connection and linear grills and other low side jobs , lifting-shifting of machine , scaffolding of machine , ms structure for outdoor units
Tender For auction sale of casting, launder lips and spouts,scrap, ss-904l,scrap edge strips,scrap frp pipes and accessories,scrap, ss-304 and lower grades,scrap, rubber,scrap - brass,scrap,rubber hose with ms connector
Tender For supply of air conditioning system : - supply of reputed make variable refrigerent flow consisting of one outdoor and multiple indoor units refer details as per specification , vrf ductable split unit refer details as per specification , odu joint refer details as per specification , refnuts details as per specification , installation of ductable unit details as per specification , copper piping 11 by 8 to 7 by 8 refer details as per specification , commissioning of cable 6 core 2 point 5 mm refer details as per specification , cpvc dreain pipe 1 inch refer details as per specification , welding work refer details as per specification , cable tray for copper pipe 16 inchs refer details as per specification , n2 pressure vaccuming and commissioning refer details as per specification , gas charging refer details as per specification , power cable 4 core 4 sqmm refer details as per specification , ducting work refer details as per specification
Tender For supply of air conditioning installation work at sbi duliajan branch c c - 1.0 tr capacity hi wall mounting 5-star rated inverter split ac , 1.5 tr capacity hi wall mounting 5-star rated inverter split ac , 2.0 tr cassette type split air conditioners inverter model 5 star , installation charges of the split type ac , installation charges of the 2.0 tr cassette split ac , reprigerent pipe for 2.0 tr cassette ac , reprigerent pipe for 1.5 split ac , 4 kva stabilizer for split ac , 5 kva stabilizer fo cassette ac , removing of existing air conditioning unit. , electronic timer for alternate operation of ac
Tender For supply of air conditioning installation work at chapangani branch c c - 1.5 tr capacity hi wall mounting 5-star rated inverter split ac , 2.0 tr capacity hi wall mounting 5-star rated inverter split ac , 2.0 tr cassette type split air conditioners inverter model 5 star , installation charges of the split type ac , installation charges of the 2.0 tr cassette split ac , reprigerent pipe for 2.0 tr cassette ac , reprigerent pipe for 1.5 split ac , 4 kva stabilizer for split ac , 5 kva stabilizer fo cassette ac , removing of existing air conditioning unit.