Get complete information related to latest Ac Unit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ac Unit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ac Unit Tenders.
Tender For corrigendum : tender for supply of supply of suitable spares for 7 5 ton ducttype ac - suitable complete control unit along with display for 7.5 ton ductable , sensors set , suitable m3pd controller , suitable compressor , suitable fan unit , 3/211 flarenut (1 pack contains 50 pieces)
Tender For procurement of various spares for rtus in ss and frtus in rmu - supply of various spares for rtu in substations and frtu in rmus, mcu 4a card 48v for rtu panel, mcu 5d card 24v for frtus, router at ss, 48v dc power supply card for rtu, 24v dc power supply card for frtu, 110v dc cmr with base, 220v dc cmr with base, 230v ac cmr with base, dc voltage transducers, com-6 expansion communication board
Tender For shortlisting of contractors for comprehensive annual maintenance contract of split and cassette acunits and water cooled package acunits for nism premises
Tender For bid to ras bid to ras corrigendum : supply of filter , supply- ac and ventilation system- air intake louver , supply- ac and ventilation system- gravity damper , supply- ac and ventilation system- axial flow supply fans- 5500 cmh , supply- ac and ventilation system- axial flow exhaust fans with flp motor -7500 cmh , spares- ac and ventilation system -v-belt for ahu blower of each type , spares- ac and ventilation system -ahu blower bearings of each type , spares- ac and ventilation system -blower motor bearing for ahu , spares- ac and ventilation system -pre filter for ahu , spares- ac and ventilation system -fine filter for ahu , spares- ac and ventilation system -relative humidity sensors , spares- ac and ventilation system - geyserstat , spares-ac and ventilation system- local humidity temperature indicators , etc- ac and ventilation system- air cooled dx type condensing unit- minimum 33 tr actual capacity , etc- ac and ventilation system- air handling unit- ahu , etc- ac and ventilation system- fresh air fan assembly , etc- ac and ventilation system- split acunit - 2 tr , etc- ac and ventilation system- strip heaters , etc- ac and ventilation system- pan humidifier , etc- ac and ventilation system- copper refrigerant piping- suction line , etc- ac and ventilation system- copper refrigerant piping-liquid line , etc- ac and ventilation system- refrigerant gas , etc- ac and ventilation system- gss duct sheet-24 g- air conditioning system , etc- ac and ventilation system- gss duct sheet-22 g- air conditioning system , etc- ac and ventilation system- gss duct sheet- 20 g- air conditioning system , etc- ac and ventilation system-gss duct sheet- 18 g- air conditioning system , etc- ac and ventilation system-non return damper , etc- ac and ventilation system-volume control damper , etc- ac and ventilation system- fire damper , etc- ac and ventilation system- motorised actuator for fire damper , etc- ac and ventilation system- grills diffusers , etc- ac and ventilation system- accoustic insulation , etc- ac and ventilation system- thermal insulation , etc- ac and ventilation system- dp switch , etc- ac and ventilation system- air flow switch , etc- ac and ventilation system- temperature cum rh sensor , etc- ac and ventilation system- fine filter , etc- ac and ventilation system- air intake louver , etc- ac and ventilation system-gravity damper , etc- ac and ventilation system- axial flow etc fans- 5500 cmh , etc- ac and ventilation system- axial flow exhaust fans with flp motor -7500 cmh , etc- ac and ventilation system-cable laying and termination alonwith lugs glands and any other accessories
Tender For providing e.i an fans , air conditioning , audio conference system and associated electrical works at proposed conference hall at 2nd floor of gmba office, cto building, dhanbad under dhanbad ba. (sh providing ei fans , itc of split acunits and as
Tender For corrigendum : supply of call base ems repair at bsnl oa himatnagar - attending fault at te below 25 km , attending fault at te 25 to 50 km , attending fault at te more than 50 km , sf 12v 88ah battery , sf 12v 130ah battery , sf 10amp 12v smps battery charger , repair smps battery charger , service of dg set 40 to 62.5kva , service of dg set 100 to 125kva , service of dg set 320 kva , 320 kvadg set starter repair , calibration of fuel pump and nozzle , service radiator for ea set upto 125 kva , service radiator for ea set upto 160 to 320 kva , rewinding 3 to 5 hp mono water pump , dol starter for 5 hp motor , repalce sreet light with 25 watts led lamp in holder , repalce sreet light with 25 watts led lamp on pole , repalce pvc box , sf 4 ft 20 w white led tl , sf 3 c 2.5 sq mm cu cond cable , sf 3 c 1.5 sq mm cu cond cable , laying xlpe cable upto 35 sq mm , end termination for 4c 10 sq mm cable , dismental acunit incl all , shifting of 1.5 tr sacunit incl all , itc of 1.5 or 2 tr split acunits , charging r 32 or r410 gas for sac , charging r 407 gas for sac , sf add copper pipe with cable for sac , sf25 mm pvc isi drain pipe , disemntaling all ems , servicing mv and lt panels incl all , repalce 400 a mccb incl shift and itc
Tender For corrigendum : supply of replacing in 1.5or2tr acunit blower fan motor , replacing in 1.5or2tr acunit blower drum , replacing in 1.5or2tr acunit condenser motor , replacing in 1.5or2tr acunit condenser fan blade , replacing in 1.5or2tr acunit pcb of indoor , replacing in 1.5or2tr acunit pcb of outdoor , replacing in 1.5 acunit rotary compressor 1.5tr , replacing in 2.0 acunit rotary compressor 2.0tr , replacing in 1.5or2tr acunit capacitor 25 35 5 mfd , replacing in 1.5or2tr acunit 25a 2 pole contactor , replacing in 1.5or2tr acunit terminal box 6w , water service of 1.5 or 2 tr acunits , blower service of 1.5 or 2 tr acunits , gas charging r22 r 134 of 1.5 or 2 tr acunits , replacing 50mm thick filter , s f of auto controller of 2 ac , replacing 25a spn mcb , site visit for ac repairing
Tender For replacement of life expired acunits with 26 nos 5 star rated 1.5 tr split type acunits and 16 nos 3.0 tr ductable acunits at various telephone exchanges /bts under andaman and nicobar circle. sw- itc of 4 nos 1.5 tr split acunits viz at mayabunde
Tender For purchase of protection system spares for power house of parbati-ii hep - reb670 main-ii busbar protection relay , resisitor unit for rxmvb4 trip relay, rxtma , trip circuit supervision relay, tsr, coil voltage: 220v&110v dc, 2c/o, article no.: in 352 001-as , high speed trip relay, rxms1 , pushbutton module for trip relay, rxt - pb unit in5396 3001 -ac , test switch, rxtp18 , test pin , bistable relay rxmvb4 (rk251 403-ah)-pb2ph , numerical relay with 50,51,51n,27u,64r protection, ctr:- -5a, 3 di & 5do , static relay mvapm32d1aa2001a operating voltage vn 110v ac , dc supply monitoring relay - vaa11yf8752ca , aux relay,aux voltage 220-250v dc,2no+2nc,reverse flag,vaa11yf7752ca , two element aux. relay,s/r type, 2no+1nc with h/r operation indicator per element - vaa21zg0750ba , bistable relay - mvajm14jb1002a1 , bistable relay- mvajm14jb1004a1 , tripping relay,mvajm25la1004a,16 no+4 nc,h/r flag,burden high , tripping relay with s/r contacts - vajs23zg1000aba , aux voltage 110-125/220-250v dc,2no+2co,reverse flag,flush mount, model no: vax31zg0750ba , trip coil supervision,1no+2nc, s/r , h/r reverse operation indicator per element - vax21zg8045bch , no volt relay, voltage rating 63.5 v, 50 hz , voltage dropping resistor - 3.3 k ohms / 35 watt with base plate , metrosil resistor- s1088 , metrosil resistor - 1196 , stabilising resistor 0 to 1000 ohms , 20hz generator for 100% stator e/f protection relay , band pass filter with built in voltage divider for 100% stator e/f protection relay