Web Analytics Made Easy - StatCounter

Acb Drift Eliminator Repair Tenders

Get complete information related to latest Acb Drift Eliminator Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Acb Drift Eliminator Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Acb Drift Eliminator Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45716314 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-146; e21 port da emergency cooling valve stuck in close position and valve spindle deteriorated defect to be rectified and system to be proved for satisfactory op..

Central Government/Public Sector

CTN :45713891 Due date: 20 Jul, 202620 Jul, 2026 20.00 Lacs
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20

CTN :45720849 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For procurement of spares for cooling towers (make-paharpur cooling towers limited) installed for cooling of circulating water for air compressor system and air conditioning system at u 7 and 8, ssctps, rvun, suratgarh - requirement of spares for cooling towers installed for cooling of circulating water for air compressor system in ahp area, model no. 6405m, grdr 20t rt-2.71:1 68-4592-1, fan assy 60in h-3-6 p85- (pcu-2/c) 3118-2, fill pack pc-47 p83-3128-1, d/s 6q cli 460 gb1.1/8 mb 38, spray nozzle p86-1082-3pp, elim pack stack pc-47 96-2034-17, branch pipe 50nb p85-1142-6, d/s coupling 6q with nbm insert gear side(gear shaft hole dia: 35 mm), d/s coupling 6q with nbm insert motor side(motor shaft hole dia: 48 mm), louvers, requirement of spares for cooling towers installed for cooling of circulating water of ac system in ca area, model no. 22103 for item s. no. 2.01-2.06 and model no. 3861 for item s. no. 2.07-2.10, fill sht mx75-8.1 lev p89- 4049-7, fill sht mx75-8.1 lev p89- 4049-8, fan assy 96in h-3-6, grdr 20t cc2, kit d/s 6q i nbm insert (rubber bush withhardware for drive shaft coupling), s.t. nozzle 68 3738-0xx pp, fill sht mx75-8.1 leh 86-4500-3, fill sht mx75-8.1 leh 86-4500-4, brg hsg assy sr118se, fan assy 54in h-3-6, requirement of stitching material for repair of damaged of frp structure of cooling towers, frp stiching material (fibre resin, fibre matstraid, mekp, cobalt, brush, chalk powder etc.)

CTN :45740558 Due date: 06 Jul, 202606 Jul, 2026 35.58 Lacs
Tender For annual repair work for enhancing cooling capacity of old ac system by installing new tower ac inside assembly house of vidhan sabha bhawan bhopal

State Government

CTN :45722560 Due date: 04 Jul, 202604 Jul, 2026 1.96 Lacs
Tender For limited bid invited for repair of two ac cooling system

Central Government/Public Sector

CTN :45702700 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For auction sale of rolling stock - pl no 98111073 condemned and unserviceable icf bg 8 wheeler coaches no. [1] special repair wgscn 056327 [2] special repair wgscn 054040 [3] special repair rt 900066 [4] special repair gslrd 046712 [5] special repair gs 066410 [6] special repair wgaccn 046111 [7] special repair wgaccn 046139 with all available ferrous-non ferrous electrical fittings with wires, lights, fans, switches, mobile chargers, batteries, battery boxes, wash basins, bio tanks, dust bins, wooden items, ss and aluminium water tanks, porcelain/ss commode/ inlay pans, wall protectors, main doors and lugguage doors, 25kva ac coach under slung inverters and its panels, power cables, pre cooling transformer, wra pumps, power panel, rmpu and control panels, change over rotor switches, rru, bp fp gauge, smoke and heat detection alarm system and there on. rate per number should be quoted. advice note no. [1] 073349-26-08907, dt 18.06.26 [2] 073349-26-08904, dt 18.06.26 [3] 073349-26-08905, dt 18.06.26 [4] 073349-26-08909, dt 18.06.26 [5] 073349-26-08908, dt 18.06.26 [6] 073349-26-08903, dt 18.06.26 [7] 073349-26-08906, dt 18.06.26. approx. weight of the coaches is 206.028 mts. on as is where is condition. note: [1] cutting permitted to cut the coach into two pieces [center cut]. [2] crane loading permitted. [3] coach in grounded condition without bogie complete set(location: mettu line nearby ipf colony office goc)

CTN :45642680 Due date: 13 Jul, 202613 Jul, 2026 29.44 Lacs
Tender For supply of supply of package type air conditioning plants of 16.5 ton capacity at akashvani rampur. equipment consisting compressor unit, air cooled condenser, cooling coil, blowers, refrigerant piping system , modification in existing plenum chamber and shall be connected to existing ducting system and will be modified to accommodate the unit. minor repair job shall be done by the firm, if required. , return air chambers at akashvani rampur , switch board and wiring of equipment at akashvani rampur , electrical earthing at akashvani rampur , itc of ac plant includes, dismantling of old ac plants, misc. jobs required for installation of ac plants and provision of indicators for filter clogging and condenser clogging at akashvani rampur , supply of package type air conditioning plant of 16.5 ton capacity at akashvani kanpur. equipment consisting compressor unit, air cooled condenser, cooling coil, blowers, refrigerant piping system , return air chambers at akashvani kanpur , switch board and wiring of equipment at akashvani kanpur , electrical earthing at akashvani kanpur , itc of ac plant includes, dismantling of old ac plants, misc. jobs required for installation of ac plants and provision of indicators for filter clogging and condenser clogging at akashvani kanpur * /bid number : gem/2026/b/7640468 + /dated: 22-06-2026 ' ' / bid document 1 / 24

CTN :45632179 Due date: 11 Jul, 202611 Jul, 2026 NA
Tender For providing of repair and overhauling service - repair of liquid refrigerant cooling unit (lrcu-70); mpr system; yes; buyer premises

CTN :45628674 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For supply of servicing of air conditioner , gas refilling of air conditioner , panel repair of air conditioner , repairing and servicing of desert cooler , desert cooler side window grass , paint silver for desert cooler , desert cooler motor rewinding , desert cooler water pump , repair of cooling system refrigerator 180 ltr , repair of cooling system of deep freezer , repair of cooling system of water cooler , repair of cooling system of water dispenser

CTN :45359599 Due date: 24 Jun, 202624 Jun, 2026 NA
Tender For bid to ras bid to ras supply of relay valve assembly service kit , pressure line hose pipes set , pressure boot assembly repair kit , pressure boot seals , the above mentioned engine pressure system over , bs iii radiator assembly , inter cooler repair , coolant plastic dat mtd single cap , radiator hose pipe , the above mentioned engine cooling system over hauling , bs iii break booster assembly , break adjuster yoke assembly , break master cylinder repair kit , the above mentioned break booster repair remove the all , clutch master cylinder assembly , the above mentioned clutch and gear over hauling repair , chain bracket assembly , chain bracket socket bearing , chain bracket cuts rubber , wheel bearing , the above mentioned mc over hauling repairs removes , head gasket kit , gear shifter and assembly , gear shifter and assembly lh rh , gear lever knob , gear lever without bu , gear lever plate , the above mentioned gear box remove and check the , shock absorber assembly , the above mentioned shock absorber remove and check , kilometer head assembly , the above mentioned kilometer head assembly remove
 Loading, Please wait...