Get complete information related to latest Acb Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Acb Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Acb Spares Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45679372 Due date: 02 Jul, 202602 Jul, 2026 20.16 Lacs
Tender For supply and replacement of defective parts of kirloskar make transformers of 1000/750/500 kva capacity at ugc & cag building, new delhi. - supply and fixing of over current earth fourth relay 24 dc l&t make etc complete as reqd. , supply and fixing of 11 kv indoor single phase resin cast current transformer 300/5amp etc complete as reqd., , supply and fixing of transformer 500 kva 11/0.433 kv wt1 scanner & rtd sencer lead., , supply & installation of suitable rating of 500 kva 11/0.433 kv lv bussing porcelain or epoxy-cast resin comply with is-1180 complete as required, , supply and fixing of suitable rating of 500 kva 11/0.433 kv lv flexible porcelain or epoxy-cast resin comply with is-1180 complete as required., , dismantling /loading and unloading of 500kva, 11kv/433volt, 3phase, 50hz, cast resin dry type kirloskar make indoor transformer hv/lv coil/core etc and repair of crack in hv/lv winding/core and putting cast resin/resin hardener, reassembling all the dismantle parts accessories confirming to is 11171 and iec 60076 etc including all tests i.e voltage ratio, magnetic balancing, vector group, ir magnetizing current, winding resistance etc complete as reqd., , supply & installation of 630a vcb vacuum interrupter etc complete as reqd., , sh-2 (old cag bldg), , supply and replacement of 750- 1000 kva transformer oil gas kit etc complete as reqd., , checking in 750-1000 kva transformer all type of protection etc complete as reqd., , supply and replacement of lv bushing oil seal in 750-1000 transformer etc complete as reqd. no.ryb) (4, , supply and replacement of hv bushing oil seal in 750-1000 transformer etc complete as reqd. (3 no. r,y, b), , supply and replacement of off load tape changer in 750-1000 kva transformer etc complete as reqd., , replacement of transformer oil in oltc top-up of main tank etc complete as reqd., transformer oil filtration and dehydration of 750 kva & 1000 kva transformer using high-vacuum oil filtration plant, including removal of moisture, dissolved gases, sludge and impurities from transformer oil, circulation of oil through filtration machine, achieving required bdv value, testing before and after filtration, manpower, tools & tackles, consumables, complete as required at site., , complete servicing, overhauling, cleaning, contact checking, lubrication, insulation resistance testing, contact resistance testing, functional testing and commissioning of oil circuit breaker (ocb), complete as required at site., , supply & installation of male contact, , supply & installation of female contact, , supply & installation of over current earth fault relay, , supply & installation of 24 volt dc power pack unit etc complete as reqd., , supply and fixing of transformer wti relay etc complete as reqd.., , supply and replacement of transformer oti relay etc complete as reqd.., , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, ics=100% icu and operational voltage 690v etc. as required., , (make: schneider electric-nsx /siemens / lk/ abb/hager)

CTN :45678234 Due date: 03 Jul, 202603 Jul, 2026 2.13 Lacs
Tender For reconditioning /repair and strengthening of vacuum circuit breaker (v.c.b) of h.t control panel of 800 amps at l.i.s rajal.

Central Government/Public Sector

CTN :45474981 Due date: 26 Jun, 202626 Jun, 2026 14.85 Lacs
Tender For technical bid for supply of hvac operational spares , bearing (6206) size: od, 60 mm x id 50 mm ball bearing desig: 6001-z, ball bearing desig: 6307/2z c3 universal hvac/r controller, armoured 4 core x 6 sqmm xlpe copper cable. 1 sqmm frls multi stranded copper cable (single wire), 10 sqmm frls multi stranded copper cable (single wire) 4 sqmm frls multi stranded copper cable (single wire), fibre glass insulated copper wire for heater size: 6 sqmm, alkaline battery volt: 9vf sealed maintenance free (smf) lean-acid battery 7ah 12v, brush width: 3 inch for painting work. loctite 495 adhesive, kiwi drain cleaner heavy duty industrial safety gloves - cut-resistant (mechanical work), spray foam insulation (pfu) can qty: 750 ml wd 40 multipurpose spray size: 500 ml, green paint (bus green synthetic enamel black paint (synthetic enamel), ms flat bar size: 40 x 5 mm ms l- angle size: 25 x 25 x 5 mm, ms l- angle size: 40 x 40 x 5 mm metal primer (red oxide), black color spary paint 400 ml thread repair helicoil insert ss-m18 x 2.5mm x 1.5d, thread repair helicoil insert ss-m20 x 2.5mm x 1.5d thread repair helicoil, insert ss-m24 x 3mm x 1.5d thinner for oil-based paints, wire type buffing whee bench grinder wheel -heavy grade, dial test indicator (dti) gauge with flexible stem magnetic base stand, digital clamp meter capacity: 600a ac trms heavy duty exhaust fan, size: 9 inch backward curved fan with motor size: 355, mm dia ventilation fan for electrical panel sweep, dia: 12 cm induction motor fan, blade shaft size: 20 mm & blade dia: 130 mm, induction motor fan blade shaft size: 25 mm, & blade dia: 110 mm gi 6 mm x 25 mm bolt & nut with washer, anchor bolt with nut & washer size: 10 mm anchor bolt with nut &, washer size: 8 mm anchor fastner size: 10, mm for threaded rod gi self tapping screw, size: 3/4 inch (20 mm) head type: truss, pop screw size: 1 inch (25 mm) head type: flat (csk). ss self tapping screw size: 2 inch (50 mm), head type: hex din rail size: 35 x 7.5 mm, add on auxiliary contact block (1 no +1 nc) casing and capping size: 20mm (3/4 inch), casing and capping size: 50mm (2 inch) copper strip for electrical motor size: 25 x 3 mm, current transformer (for mfm/ammeter), ratio: 10/5a current transformer (for mfm/ammeter), ratio: 15/5a, current transformer (for mfm/ammeter), ratio: 20/5a current transformer (for mfm/ammeter), ratio: 30/5a, current transformer (for mfm/ammeter), ratio: 5/5a emergency stop switch, metal enclosure electrical junction box, size: 200mmx200mmx150mm, metal enclosure electrical junction box size:, 300mmx300mmx200mm three pole neutral (4p), 32 amps miniature circuit breaker (mcb) 4-way mcb metal enclosure, 2- module surface mounted pvc box. thermal overload relay, range: 14-23 amps electronic fan regulator, single module porcelain heater insulators or terminal. blocks, led indicator color: amber pin type lug size: 1.5 sqmm, pin type lug size: 2.5 sqmm pin type lug size: 4 sqmm, pin type lug size: 6 sqmm spade type lug size: 1.5 sqmm, spade type lug size: 2.5 sqmm metal flexible conduit size:19, motor protection circuit breaker (mpcb) range: 6.3-10 amps (rotary) motor protection circuit breaker (mpcb) inst trip rating: 2.5 amps (rotary), motor protection circuit breaker (mpcb) inst trip rating: 25 amps (rotary) motor protection circuit breaker (mpcb) inst trip rating: 50 amps (rotary), ms conduit size: 25 mm motor terminal block range: 10 hp/7.5 kw, motor terminal block range: 40 hp/30 kw thermal overload relay(olr) range: 20-33 amps, thermal overload relay(olr) range: 42-69 amps plug top 3 pin capacity: 5 amps, 4 pole power contactor capacity: mnx 12 4 pole power contactor capacity: mnx 18, 4 pole power contactor capacity: mnx 9 push button (illuminated) color: green, push button (illuminated) color: red plugable interface relay (4 c/o, 230 vac) with base, plugable interface relay (4 c/o, 24 vac) with base analog timer controller for split ac's, terminal block range: 0.2-2.5 sqmm,

State Government

CTN :45409030 Due date: 10 Jun, 202610 Jun, 2026 8.39 Lacs
Tender For repair maintenance of specialized electrical and mechanical services at tis hazari court complex, delhi. (sh supply and replacement of wornout/faulty air circuit breaker (acb) of the existing lt panel and motorized changer over switch.)

CTN :45205792 Due date: 29 May, 202629 May, 2026 1.80 Lacs
Tender For corrigendum : reconditioning/repair/strengthening of vaccum circuit breaker (v.c.b) of h.t control panel of 800 amps of avr at l.i.s. rajal.

CTN :44842484 Due date: 29 May, 202629 May, 2026 NA
Tender For corrigendum : dr.mvr rtpp-stage-ii-em&mrt-procurement of ge make spectronic s4000 amps 3 pole acb spares-offer-req-reg