Get complete information related to latest Access Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Access Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Access Switch Tenders.
Tender For corrigendum : supply of router , layer 3 core switch , accessswitch type 1 , accessswitch type 2 , accessswitch type 3 , accesses switch type 4 , indoor access point ap , outdoor access point ap , wireless lan controller hardware , authentication, authorization and accounting aaa appliance with support high availability along with solid state drive and redundant power supply , authentication, authorization and accounting aaa and network admission control nac license , unified endpoint management uem with 5 years support , endpoint detection and response edr with 5 years support , 1g copper sfp of same oem as of hardware , 1g fibre single mode sm sfp of same oem as of hardware , 10g fibre single mode sm sfp of same oem as of hardware , 40g fibre single mode sm sfp of same oem as of hardware , centralized ups of one hour power backup to commensurate capacity for each tower alongwith power cabling from ups to each rack with accessories , cat 6a shielded 4 pair cable lszh indoor , cat 6a shielded field termination plug for waps , cat 6a shielded 1u 24 port patch panels , cat 6a shielded patch cord, lszh, 1m, rack end , cat 6a shielded patch cord, lszh, 2m, rack end , cable manager 1u , 12f os2 multi tube fiber cable , 24f os2 multi tube fiber cable , 24f os2 port configurable fiber sliding drawer lc type loaded , 48f os2 port configurable fiber sliding drawer lc type loaded , lc lc, os2, duplex fiber optic patch cords 5m , lc lc, os2, duplex fiber optic patch cords 3m , 48f fiber encloser jointer for field , 36u networking rack with power availability, temperature and humidity monitoring , 42u networking rack with power availability, temperature and humidity monitoring , chemical earthing for each rack
Tender For bid to ras supply installation integration and commissioning of ip based cctv cameras with 5 years camc - ofc 06 cores primary fiber , ofc 02 cores secondary fiber , plc splitters 1x8 single mode , plc splitters 1x16 single mode , liu 6 cores outdoor type loaded , 5 mtrs patch chord sc-lc , optical line terminal olt device loaded with 04 sfp modules. , outdoor water resistance box with pole mount arrangement for housing of ups, onu, spike guard etc. , 1 kva ups with 02 nos. of inbuilt battery , onu optical network unit device with 01 onu port 10-100-1000 mbps plus 2x10-100-1000 mbps ethernet ports. , ip based ptz camera , ip based fixed camera , power supply device for ptz camera , power supply device for fixed camera , memory card micro sd 128 gb for ptz camera , cat-6 stp cable, conductor count in nos. - 8 , 6u network rack , 24u network rack , 5 gigabit ethernet ports with poe on minimum 4 ports , hdd of 6tb surveillance hard disc - interface - sata , nvr 128 channel with vms , led screen 32 inch , spike guard , power cable - 1.5 mm 3 core flexible wire , memory card micro sd 64 gb for fixed camera , 8 port gigabit unmanaged network switch , 8 ports poe gigabit switch with 01 sfp cage , 16 ports gigabit poe with 02 sfp cage , media converter , installation testing and commissioning charges , fibre laying , ofc splicing , camc charges for 1st year after completion of 1 year of warranty period from the date of commissioning , camc charges for 2nd year , camc charges for 3rd year , camc charges for 4th year , camc charges for 5th year
Tender For corrigendum : supply of ems repair at bsnl tele bhavan ahmedabad f f - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair
Tender For supply of chassis core switch with min 6 slots or more and with line cards and sup engines transceivers with 3 years warranty , 42 u network rack , distribution switch with transceivers , software define controller with vmware software with a rack server , accessswitch , 09 u network rack , 06 u network rack , 12 core single mode ofc armoured , 48 core armoured ofc cable laying in south campus , hdpe pipe , ofc liu 24 ports , rj 45 patch panel fully loaded , cat 6 patch chord 2 mtrs , cat 6 patch chord 1 mtrs , 10 kva online ups with battery 120 minutes back up , armoured lc sc mm ofc duplex patch chord 2 mtrs , armoured lc lc sm ofc duplex patch chord 2 mtrs , armoured lc sc sm ofc duplex patch chord 2mtrs , cat7 patch cord 10 mtr 10g support , cat7 patch cord 5 mtr 10g support , armoured lc sc mm duplex patch cord 5 mtr , armoured lc sc sm duplex patch cord 5 mtr , armoured lc lc mm duplex patch cord 5 mtr , armoured lc lc sm duplex patch cord 5 mtr , cat 6a utp cable 10 gbps capability , io boxand back boxand face plate with keystone , 2 inch pvc capping or casing pipe , 1 inch pvc capping or casing pipe , 1 inch and 2 inch bend or l or t connectors to complete the solution or installation , 8 port serial consol server aten sn9108c0 or equivalent of higher all accessories to be added , 6 core ofc cable , omada pro ax5400 eap 670 ceiling mount wifi 6 access point , brick chamber or manhole size 1 m x1 x1 point 5 mtr considering all 5 locations , underground ofc laying using hdd method though hdpe pipe , pulling of fiber cable through hdpe pipes , construction of brick chamber or manhole size 1 m x1 x1 point 5 mtr considering all 5 locations , ofc splicing 24 in et cell plus 120 in admin rack plus 24 each in 5 buildings 24 x 5 is equal to 120 total 264 cores , ofc laying rcc root or join indicator of height min 2 mtrs or more //bid details 2 / 31