Get complete information related to latest Acoustic Chamber Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Acoustic Chamber Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Acoustic Chamber Tenders.
Tender For annual maintenance contract of installed e&m equipments in central drug standard control organization, gothapatna, bhubaneswar for financial year 2026-27. - & minor repairs of cctv & including, & minor repairs of kone lift i/c, (standard deviation colour matching), (standard deviation colour matching), (t.c.). manufactures word mark/, (unified glare rating) < 19, flicker, / 6500°k (as per ansi bin), sdcm, /6500°k (as per ansi bin),sdcm, <3,, <5, maximum power consumption, >85%, input voltage: 140-270 volt ac,, >85%, operating voltage ac 140-270, >85%, operating voltage ac 140-270, >85%,thd < 10% as per iec 61000-, 1 2,22,718.00 job 2,22,718.00 mr, 1 no 13 passenger lift,, 1.5 sq. mm frls/hffr, pvc, 10% , p. f.≥0.95, ip20, cri ≥80, ugr, 10.1 18 watt 10 618.00 each 6,180.00 mr, 10322 with driver as per the, 11.1 36 watt 10 2,103.00 each 21,030.00 mr, 12 13,877.00 month 1,66,524.00 mr, 12 16,961.00 month 2,03,532.00 mr, 12 21,586.00 month 2,59,032.00 mr, 12 24,086.00 month 289032 mr, 12 24,128.00 month 2,89,536.00 mr, 12 31,890.00 month 382680 mr, 12 4,490.00 month 53,880.00 mr, 12 53,452.00 month 6,41,424.00 mr, 125 kva dg set with amf and, 15u rack 1 13,330.00 nos 13,330.00, 2 x 6 sockets 16a power distribution, 2.5 kv with short & open circuit, 3-2, p. f.≥0.95, ip-66,ik-10, cri >70,, 39.23.3, 4000°k/ 5700°k /6500°k (as per ansi, 61000-4-5, driver efficiency, 70% of initial lumen maintained till life, 70% of initial lumen maintained till life, 90°c)., 90°c)., above 90°c)., aluminium body including trim, aluminium body with driver as per the, and earthing etc. as required with, annual comprehensive maintenance, annual comprehensive, maintenance, annual comprehensive, maintenance, approved by engineer-in-charge as, approved by engineer-in-charge as, approved by engineer-in-charge as, as required, as required., at gothapatna as required, attached & following staff., basis as per terms & conditions, basis) including servicing, preventive, bin), sdcm (standard deviation, bis standard complete in all respect, bis standards and trade mark, body material with pmma and, cable and earthing etc. as required, cable and earthing etc. as required, cables, nvr, switch, cctv camera,, cct 3000°k / 4000°k / 5700°k, cdtl building etc. as reqd., centigrade, internal surge protection of, certificate (t.c.). manufactures word, circuitry) of minimum 50000 burning, colour matching) <3,, commissiong of pa, rectification and, comprehensive and repair, comprehensive and repair, comprehensive and repair, condition at cdtl office building etc, contract (as inspection on monthly, copper conductor single core cable, day electrical complaints, complaint, distribution pane, 250 kva substation,, down lighter (round/ square/, driver & electrical circuitry), of, dsr-25, efficacy ≥105 <120 lm/watt) supplying, ends , cct 3000°k / 4000°k / 5700°k, ends as per lm80 extrapolation ies, entire lift , etc in cdtl office building, etc in cdtl office at gothapatna as, extrapolation ies tm-21-11 report,, fixture shall be confirming to relevant, fixture shall be of relevant bis, fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., fixtures as per bis shall be submitted., free, (flicker should be below 5 %), life, frequency 50/60 hz, operating temp, general shift) at cdsco on monthly, hours with70% of initial lumen, housing such that led, housing such that led junction, housing such that led junction, i/c external connections with 1.5, in all respect i/c external connections, inspection on monthly basis) including, inspection on monthly basis) including, insulated copper conductor single core, insulated copper conductor single core, internal surge protection of 2.5 kv with, ip surveillance systems i/c maintance, ip20, cri ≥80 , ugr (unified glare, junctiontemperature shall not rise, knocked-down condition (ckd) shape,, led panel light 2x2 ft. (system lumen, lenses for beam angle asper iesna, life time (led, driver &
Tender For repair maintenance of ei and fans, wet riser, firefighting and sprinkler system, lift, dg sets, 11/0.433 kv substation etc at gpoa building (kendralaya), sanjay place, agra. (sh: day to day maintenance and repair of gopa building)
Tender For annual repair and maintenance for civil and sanitary and plumbing works at swasthya bhawan main building, granthagar bhawan, substation, drivers room in the campus of swasthya bhawan complex for the year 2026 27
Tender For maintenance of electrical installation & fans in all residential & non-residential building, o/m of e&m equipments including repair and maintenance of pumpsets, substation equipments, dg sets & oh lines at svp npa, hyderabad. sh: operation of 33 kv substation, o&m of 11 kv substation, iei & fans, street lights, pumpsets, dg sets, fire alarm,. firefighting equipments during the year 2025-2026. sh: replacement of old wiring with new wiring including providing of new power points and light points, cables, fittings, fans etc, in v/10 quarters at site-b of svp npa, hyderabad.
Tender For 1) maintenance of electrical installation and fans repair and maintenance of 315 kva substation equipments a/c units diesel generator set pump set for office cum lab building at directorate of (map) boriavi and residential at lambhel (f.y.2026-27)subwork/packages:servicing and maintenance of split / cassette type mounted type air conditioning units at office building boriavi